SSA-693975
Vulnerability from csaf_siemens - Published: 2023-12-12 00:00 - Updated: 2024-03-12 00:00| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
SIMATIC CP 1242-7 V2 (incl. SIPLUS variants)
Siemens / SIMATIC CP 1242-7 V2 (incl. SIPLUS variants)
|
<V3.4.29 |
Mitigation
Vendor Fix
fix
|
|
|
SIMATIC CP 1243-1 (incl. SIPLUS variants)
Siemens / SIMATIC CP 1243-1 (incl. SIPLUS variants)
|
<V3.4.29 |
Mitigation
Vendor Fix
fix
|
|
|
SIMATIC CP 1243-1 DNP3 (incl. SIPLUS variants)
Siemens / SIMATIC CP 1243-1 DNP3 (incl. SIPLUS variants)
|
vers:all/* |
Mitigation
No Fix Planned
|
|
|
SIMATIC CP 1243-1 IEC (incl. SIPLUS variants)
Siemens / SIMATIC CP 1243-1 IEC (incl. SIPLUS variants)
|
<V3.4.29 |
Mitigation
Vendor Fix
fix
|
|
|
SIMATIC CP 1243-7 LTE
Siemens / SIMATIC CP 1243-7 LTE
|
<V3.4.29 |
Mitigation
Vendor Fix
fix
|
|
|
SIMATIC CP 1243-8 IRC (6GK7243-8RX30-0XE0)
Siemens / SIMATIC CP 1243-8 IRC (6GK7243-8RX30-0XE0)
|
6GK7243-8RX30-0XE0
|
<V3.4.29 |
Mitigation
Vendor Fix
fix
|
|
SIMATIC CP 1543-1 (6GK7543-1AX00-0XE0)
Siemens / SIMATIC CP 1543-1 (6GK7543-1AX00-0XE0)
|
6GK7543-1AX00-0XE0
|
<V3.0.37 |
Mitigation
Vendor Fix
fix
|
|
SINAMICS S210 (6SL5...)
Siemens / SINAMICS S210 (6SL5...)
|
All versions >= V6.1 < V6.1 HF2 |
Mitigation
Vendor Fix
fix
|
|
|
SIPLUS NET CP 1543-1 (6AG1543-1AX00-2XE0)
Siemens / SIPLUS NET CP 1543-1 (6AG1543-1AX00-2XE0)
|
6AG1543-1AX00-2XE0
|
<V3.0.37 |
Mitigation
Vendor Fix
fix
|
{
"document": {
"category": "csaf_security_advisory",
"csaf_version": "2.0",
"distribution": {
"text": "Disclosure is not limited. (TLPv2: TLP:CLEAR)",
"tlp": {
"label": "WHITE"
}
},
"lang": "en",
"notes": [
{
"category": "summary",
"text": "A vulnerability in the affected products could allow an unauthorized attacker with network access to the webserver of an affected device to perform a denial-of-service attack.\n\nSiemens has released a new version for SINAMICS S210 (6SL5...) and recommends to update to the latest version. Siemens recommends specific countermeasures for products where fixes are not, or not yet available.",
"title": "Summary"
},
{
"category": "general",
"text": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity",
"title": "General Recommendations"
},
{
"category": "general",
"text": "For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories",
"title": "Additional Resources"
},
{
"category": "legal_disclaimer",
"text": "Siemens Security Advisories are subject to the terms and conditions contained in Siemens\u0027 underlying license terms or other applicable agreements previously agreed to with Siemens (hereinafter \"License Terms\"). To the extent applicable to information, software or documentation made available in or through a Siemens Security Advisory, the Terms of Use of Siemens\u0027 Global Website (https://www.siemens.com/terms_of_use, hereinafter \"Terms of Use\"), in particular Sections 8-10 of the Terms of Use, shall apply additionally. In case of conflicts, the License Terms shall prevail over the Terms of Use.",
"title": "Terms of Use"
}
],
"publisher": {
"category": "vendor",
"contact_details": "productcert@siemens.com",
"name": "Siemens ProductCERT",
"namespace": "https://www.siemens.com"
},
"references": [
{
"category": "self",
"summary": "SSA-693975: Denial-of-Service Vulnerability in the Web Server of Industrial Products - HTML Version",
"url": "https://cert-portal.siemens.com/productcert/html/ssa-693975.html"
},
{
"category": "self",
"summary": "SSA-693975: Denial-of-Service Vulnerability in the Web Server of Industrial Products - CSAF Version",
"url": "https://cert-portal.siemens.com/productcert/csaf/ssa-693975.json"
},
{
"category": "self",
"summary": "SSA-693975: Denial-of-Service Vulnerability in the Web Server of Industrial Products - PDF Version",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-693975.pdf"
},
{
"category": "self",
"summary": "SSA-693975: Denial-of-Service Vulnerability in the Web Server of Industrial Products - TXT Version",
"url": "https://cert-portal.siemens.com/productcert/txt/ssa-693975.txt"
}
],
"title": "SSA-693975: Denial-of-Service Vulnerability in the Web Server of Industrial Products",
"tracking": {
"current_release_date": "2024-03-12T00:00:00Z",
"generator": {
"engine": {
"name": "Siemens ProductCERT CSAF Generator",
"version": "1"
}
},
"id": "SSA-693975",
"initial_release_date": "2023-12-12T00:00:00Z",
"revision_history": [
{
"date": "2023-12-12T00:00:00Z",
"legacy_version": "1.0",
"number": "1",
"summary": "Publication Date"
},
{
"date": "2024-03-12T00:00:00Z",
"legacy_version": "1.1",
"number": "2",
"summary": "Added fixes for supported SIMATIC S7-1200 CP 1200 family, added fix version for SIMATIC CP1200 family and SIMATIC CP1500 family"
}
],
"status": "interim",
"version": "2"
}
},
"product_tree": {
"branches": [
{
"branches": [
{
"branches": [
{
"category": "product_version_range",
"name": "\u003cV3.4.29",
"product": {
"name": "SIMATIC CP 1242-7 V2 (incl. SIPLUS variants)",
"product_id": "1"
}
}
],
"category": "product_name",
"name": "SIMATIC CP 1242-7 V2 (incl. SIPLUS variants)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003cV3.4.29",
"product": {
"name": "SIMATIC CP 1243-1 (incl. SIPLUS variants)",
"product_id": "2"
}
}
],
"category": "product_name",
"name": "SIMATIC CP 1243-1 (incl. SIPLUS variants)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SIMATIC CP 1243-1 DNP3 (incl. SIPLUS variants)",
"product_id": "3"
}
}
],
"category": "product_name",
"name": "SIMATIC CP 1243-1 DNP3 (incl. SIPLUS variants)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003cV3.4.29",
"product": {
"name": "SIMATIC CP 1243-1 IEC (incl. SIPLUS variants)",
"product_id": "4"
}
}
],
"category": "product_name",
"name": "SIMATIC CP 1243-1 IEC (incl. SIPLUS variants)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003cV3.4.29",
"product": {
"name": "SIMATIC CP 1243-7 LTE",
"product_id": "5"
}
}
],
"category": "product_name",
"name": "SIMATIC CP 1243-7 LTE"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003cV3.4.29",
"product": {
"name": "SIMATIC CP 1243-8 IRC (6GK7243-8RX30-0XE0)",
"product_id": "6",
"product_identification_helper": {
"model_numbers": [
"6GK7243-8RX30-0XE0"
]
}
}
}
],
"category": "product_name",
"name": "SIMATIC CP 1243-8 IRC (6GK7243-8RX30-0XE0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003cV3.0.37",
"product": {
"name": "SIMATIC CP 1543-1 (6GK7543-1AX00-0XE0)",
"product_id": "7",
"product_identification_helper": {
"model_numbers": [
"6GK7543-1AX00-0XE0"
]
}
}
}
],
"category": "product_name",
"name": "SIMATIC CP 1543-1 (6GK7543-1AX00-0XE0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "All versions \u003e= V6.1 \u003c V6.1 HF2",
"product": {
"name": "SINAMICS S210 (6SL5...)",
"product_id": "8"
}
}
],
"category": "product_name",
"name": "SINAMICS S210 (6SL5...)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003cV3.0.37",
"product": {
"name": "SIPLUS NET CP 1543-1 (6AG1543-1AX00-2XE0)",
"product_id": "9",
"product_identification_helper": {
"model_numbers": [
"6AG1543-1AX00-2XE0"
]
}
}
}
],
"category": "product_name",
"name": "SIPLUS NET CP 1543-1 (6AG1543-1AX00-2XE0)"
}
],
"category": "vendor",
"name": "Siemens"
}
]
},
"vulnerabilities": [
{
"cve": "CVE-2023-38380",
"cwe": {
"id": "CWE-401",
"name": "Missing Release of Memory after Effective Lifetime"
},
"notes": [
{
"category": "summary",
"text": "The webserver implementation of the affected products does not correctly release allocated memory after it has been used.\r\n\r\nAn attacker with network access could use this vulnerability to cause a denial-of-service condition in the webserver of the affected product.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"1",
"2",
"3",
"4",
"5",
"6",
"7",
"8",
"9"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Restrict network access to the integrated webserver",
"product_ids": [
"1",
"2",
"3",
"4",
"5",
"6",
"7",
"8",
"9"
]
},
{
"category": "no_fix_planned",
"details": "Currently no fix is planned",
"product_ids": [
"3"
]
},
{
"category": "vendor_fix",
"details": "Update to V3.0.37 or later version",
"product_ids": [
"7",
"9"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109828349/"
},
{
"category": "vendor_fix",
"details": "Update to V3.4.29 or later version",
"product_ids": [
"1",
"2",
"4",
"5",
"6"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109823721/"
},
{
"category": "vendor_fix",
"details": "Update to V6.1 HF2 or later version",
"product_ids": [
"8"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109825153/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.5,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"1",
"2",
"3",
"4",
"5",
"6",
"7",
"8",
"9"
]
}
],
"title": "CVE-2023-38380"
}
]
}
Drag nodes to arrange them. Double-click a related vulnerability to open it, or a source to visit its link. The Physics button on the left tunes the layout and the simulation; the legend at the bottom left hides or shows nodes by kind and by sighting type.
Sightings
| Author | Source | Type | Date | Other |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Vulnerability timeline
Sightings and recorded dates, grouped by day · UTC
How durations are calculated
Following the VTEM framework (Black Hat USA 2015), time to patch starts when the vendor or a coordinator was informed, total time to patch at discovery, and disclosure to patch at public disclosure; vendor response time runs from the report to its acknowledgement. Time to exploit and time unpatched start at the earliest discovery or report, falling back to public disclosure. Unpatched time ends at the first recorded patch, or the calculation time when no patch is recorded. Exploitation to patch shows the interval between those two events; a published proof of concept is a public exploit, not exploitation.
Each result shows its source dates. A negative interval means the end event came first; when date-only inputs leave the order open, the result says so. Date-only inputs are approximate. The earliest evidence wins: KEV report dates and sightings are labelled as such. Records describing another vulnerability are listed but never calculated from, and a PoC alone does not establish exploitation. Missing patch evidence does not prove that no patch exists. Filters below change the event list only.
Loading timeline…
The approach is described in our paper Mapping CVEs to MITRE ATT&CK Techniques: A Curated Gold-Set Classifier and the Limits of LLM-Assisted Label Expansion.
Browse all ATT&CK techniques and the vulnerabilities related to each.
Related by attack behaviour
Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.