Vulnerability from csaf_siemens - Published: 2021-07-13 00:00 - Updated: 2022-08-09 00:00| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
SIMATIC PCS 7 V8.2 and earlier
Siemens / SIMATIC PCS 7 V8.2 and earlier
|
vers:all/* |
Mitigation
No Fix Planned
|
|
|
SIMATIC PCS 7 V9.X
Siemens / SIMATIC PCS 7 V9.X
|
< V9.1 SP2 |
Mitigation
Vendor Fix
fix
|
|
|
SIMATIC PDM
Siemens / SIMATIC PDM
|
< V9.2 SP2 |
Mitigation
Vendor Fix
fix
|
|
|
SIMATIC STEP 7 V5.X
Siemens / SIMATIC STEP 7 V5.X
|
< V5.7 |
Mitigation
Vendor Fix
fix
|
|
|
SINAMICS STARTER (containing STEP 7 OEM version)
Siemens / SINAMICS STARTER (containing STEP 7 OEM version)
|
< V5.4 SP2 HF1 |
Mitigation
Vendor Fix
fix
|
{
"document": {
"category": "csaf_security_advisory",
"csaf_version": "2.0",
"distribution": {
"text": "Disclosure is not limited.",
"tlp": {
"label": "WHITE"
}
},
"notes": [
{
"category": "summary",
"text": "Multiple SIMATIC software products are affected by a vulnerability\nthat could allow an attacker to change the content of certain\nmetafiles and subsequently manipulate parameters or behaviour of\ndevices configured by the affected software products.\n\nSiemens has released updates for several affected products and\nrecommends to update to the latest versions. Siemens is preparing\nfurther updates and recommends specific countermeasures for products\nwhere updates are not, or not yet available.",
"title": "Summary"
},
{
"category": "general",
"text": "As a general security measure, Siemens strongly recommends to protect\nnetwork access to devices with appropriate mechanisms. In order to\noperate the devices in a protected IT environment, Siemens recommends\nto configure the environment according to Siemens\u0027 operational\nguidelines for Industrial Security (Download:\nhttps://www.siemens.com/cert/operational-guidelines-industrial-\nsecurity), and to follow the recommendations in the product manuals.\n\nAdditional information on Industrial Security by Siemens can be found\nat: https://www.siemens.com/industrialsecurity",
"title": "General Recommendations"
},
{
"category": "general",
"text": "For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories",
"title": "Additional Resources"
},
{
"category": "legal_disclaimer",
"text": "Siemens Security Advisories are subject to the terms and conditions contained in Siemens\u0027 underlying license terms or other applicable agreements previously agreed to with Siemens (hereinafter \"License Terms\"). To the extent applicable to information, software or documentation made available in or through a Siemens Security Advisory, the Terms of Use of Siemens\u0027 Global Website (https://www.siemens.com/terms_of_use, hereinafter \"Terms of Use\"), in particular Sections 8-10 of the Terms of Use, shall apply additionally. In case of conflicts, the License Terms shall prevail over the Terms of Use.",
"title": "Terms of Use"
}
],
"publisher": {
"category": "vendor",
"contact_details": "productcert@siemens.com",
"name": "Siemens ProductCERT",
"namespace": "https://www.siemens.com"
},
"references": [
{
"category": "self",
"summary": "SSA-661034: Incorrect Permission Assignment in Multiple SIMATIC Software Products - PDF Version",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-661034.pdf"
},
{
"category": "self",
"summary": "SSA-661034: Incorrect Permission Assignment in Multiple SIMATIC Software Products - TXT Version",
"url": "https://cert-portal.siemens.com/productcert/txt/ssa-661034.txt"
},
{
"category": "self",
"summary": "SSA-661034: Incorrect Permission Assignment in Multiple SIMATIC Software Products - CSAF Version",
"url": "https://cert-portal.siemens.com/productcert/csaf/ssa-661034.json"
}
],
"title": "SSA-661034: Incorrect Permission Assignment in Multiple SIMATIC Software Products",
"tracking": {
"current_release_date": "2022-08-09T00:00:00Z",
"generator": {
"engine": {
"name": "Siemens ProductCERT CSAF Generator",
"version": "1"
}
},
"id": "SSA-661034",
"initial_release_date": "2021-07-13T00:00:00Z",
"revision_history": [
{
"date": "2021-07-13T00:00:00Z",
"legacy_version": "1.0",
"number": "1",
"summary": "Publication Date"
},
{
"date": "2021-09-14T00:00:00Z",
"legacy_version": "1.1",
"number": "2",
"summary": "Added solution for SINAMICS STARTER"
},
{
"date": "2022-08-09T00:00:00Z",
"legacy_version": "1.2",
"number": "3",
"summary": "Added solution to SIMATIC PCS 7 V9.X and SIMATIC PDM"
}
],
"status": "final",
"version": "3"
}
},
"product_tree": {
"branches": [
{
"branches": [
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SIMATIC PCS 7 V8.2 and earlier",
"product_id": "1"
}
}
],
"category": "product_name",
"name": "SIMATIC PCS 7 V8.2 and earlier"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c V9.1 SP2",
"product": {
"name": "SIMATIC PCS 7 V9.X",
"product_id": "2"
}
}
],
"category": "product_name",
"name": "SIMATIC PCS 7 V9.X"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c V9.2 SP2",
"product": {
"name": "SIMATIC PDM",
"product_id": "3"
}
}
],
"category": "product_name",
"name": "SIMATIC PDM"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c V5.7",
"product": {
"name": "SIMATIC STEP 7 V5.X",
"product_id": "4"
}
}
],
"category": "product_name",
"name": "SIMATIC STEP 7 V5.X"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c V5.4 SP2 HF1",
"product": {
"name": "SINAMICS STARTER (containing STEP 7 OEM version)",
"product_id": "5"
}
}
],
"category": "product_name",
"name": "SINAMICS STARTER (containing STEP 7 OEM version)"
}
],
"category": "vendor",
"name": "Siemens"
}
]
},
"vulnerabilities": [
{
"cve": "CVE-2021-31894",
"cwe": {
"id": "CWE-732",
"name": "Incorrect Permission Assignment for Critical Resource"
},
"notes": [
{
"category": "summary",
"text": "A directory containing metafiles relevant to devices\u0027 configurations has write permissions.\nAn attacker could leverage this vulnerability by changing the content of certain metafiles and subsequently manipulate parameters or behavior of devices that would be later configured by the affected software.\n\n\n",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"1",
"2",
"3",
"4",
"5"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Restrict access on the engineering station to trusted users only",
"product_ids": [
"1",
"2",
"3",
"4",
"5"
]
},
{
"category": "no_fix_planned",
"details": "Currently no fix is planned",
"product_ids": [
"1"
]
},
{
"category": "vendor_fix",
"details": "Update to V5.7 or later version",
"product_ids": [
"4"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109794088/"
},
{
"category": "vendor_fix",
"details": "Update to V5.4 SP2 HF1 or later version",
"product_ids": [
"5"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109800526/"
},
{
"category": "vendor_fix",
"details": "Update to V9.1 SP2 or later version",
"product_ids": [
"2"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109812240/"
},
{
"category": "vendor_fix",
"details": "Update to V9.2 SP2 or later version",
"product_ids": [
"3"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109811911/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.3,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:C/C:N/I:H/A:L/E:U/RL:O/RC:C",
"version": "3.1"
},
"products": [
"1",
"2",
"3",
"4",
"5"
]
}
],
"title": "CVE-2021-31894"
}
]
}
Drag nodes to arrange them. Double-click a related vulnerability to open it, or a source to visit its link. The Physics button on the left tunes the layout and the simulation; the legend at the bottom left hides or shows nodes by kind and by sighting type.
Sightings
| Author | Source | Type | Date | Other |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Vulnerability timeline
Sightings and recorded dates, grouped by day · UTC
How durations are calculated
Following the VTEM framework (Black Hat USA 2015), time to patch starts when the vendor or a coordinator was informed, total time to patch at discovery, and disclosure to patch at public disclosure; vendor response time runs from the report to its acknowledgement. Time to exploit and time unpatched start at the earliest discovery or report, falling back to public disclosure. Unpatched time ends at the first recorded patch, or the calculation time when no patch is recorded. Exploitation to patch shows the interval between those two events; a published proof of concept is a public exploit, not exploitation.
Each result shows its source dates. A negative interval means the end event came first; when date-only inputs leave the order open, the result says so. Date-only inputs are approximate. The earliest evidence wins: KEV report dates and sightings are labelled as such. Records describing another vulnerability are listed but never calculated from, and a PoC alone does not establish exploitation. Missing patch evidence does not prove that no patch exists. Filters below change the event list only.
Loading timeline…
The approach is described in our paper Mapping CVEs to MITRE ATT&CK Techniques: A Curated Gold-Set Classifier and the Limits of LLM-Assisted Label Expansion.
Browse all ATT&CK techniques and the vulnerabilities related to each.
Related by attack behaviour
Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.