GCVE Workshop - 22 September 2026 (14:00-18:00), Luxembourg Before The Vulnopticon Conference - Registration

SSA-634640

Vulnerability from csaf_siemens - Published: 2025-04-08 00:00 - Updated: 2025-07-08 00:00
Summary
SSA-634640: Weak Authentication Vulnerability in Siemens Industrial Edge Devices
Notes
Summary: Siemens Industrial Edge Devices contain a weak authentication vulnerability that could facilitate an unauthenticated remote attacker to circumvent authentication and impersonate a legitimate user. Siemens has released new versions for the affected products and recommends to update to the latest versions.
General Recommendations: As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens' operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals. Additional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity
Additional Resources: For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories
Terms of Use: The use of Siemens Security Advisories is subject to the terms and conditions listed on: https://www.siemens.com/productcert/terms-of-use.
CWE-1390 - Weak Authentication
Affected products
Product Identifier Version Remediation
Industrial Edge Own Device (IEOD)
Siemens / Industrial Edge Own Device (IEOD)
All versions < V1.21.1-1-a
Mitigation
Vendor Fix fix
Industrial Edge Virtual Device
Siemens / Industrial Edge Virtual Device
All versions < V1.21.1-1-a
Mitigation
Vendor Fix fix
SCALANCE LPE9413 (6GK5998-3GS01-2AC2)
Siemens / SCALANCE LPE9413 (6GK5998-3GS01-2AC2)
6GK5998-3GS01-2AC2 vers:all/<V2.1
Mitigation
Vendor Fix fix
SIMATIC IPC127E Industrial Edge Device
Siemens / SIMATIC IPC127E Industrial Edge Device
vers:all/<V3.0
Mitigation
Vendor Fix fix
SIMATIC IPC227E Industrial Edge Device
Siemens / SIMATIC IPC227E Industrial Edge Device
vers:all/<V3.0
Mitigation
Vendor Fix fix
SIMATIC IPC427E Industrial Edge Device
Siemens / SIMATIC IPC427E Industrial Edge Device
vers:all/<V3.0
Mitigation
Vendor Fix fix
SIMATIC IPC847E Industrial Edge Device
Siemens / SIMATIC IPC847E Industrial Edge Device
vers:all/<V3.0
Mitigation
Vendor Fix fix
SIMATIC IPC BX-39A Industrial Edge Device
Siemens / SIMATIC IPC BX-39A Industrial Edge Device
vers:all/<V3.0
Mitigation
Vendor Fix fix
SIMATIC IPC BX-59A Industrial Edge Device
Siemens / SIMATIC IPC BX-59A Industrial Edge Device
vers:all/<V3.0
Mitigation
Vendor Fix fix

{
  "document": {
    "category": "csaf_security_advisory",
    "csaf_version": "2.0",
    "distribution": {
      "text": "Disclosure is not limited. (TLPv2: TLP:CLEAR)",
      "tlp": {
        "label": "WHITE"
      }
    },
    "lang": "en",
    "notes": [
      {
        "category": "summary",
        "text": "Siemens Industrial Edge Devices contain a weak authentication vulnerability that could facilitate an unauthenticated remote attacker to circumvent authentication and impersonate a legitimate user.\n\nSiemens has released new versions for the affected products and recommends to update to the latest versions.",
        "title": "Summary"
      },
      {
        "category": "general",
        "text": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity",
        "title": "General Recommendations"
      },
      {
        "category": "general",
        "text": "For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories",
        "title": "Additional Resources"
      },
      {
        "category": "legal_disclaimer",
        "text": "The use of Siemens Security Advisories is subject to the terms and conditions listed on: https://www.siemens.com/productcert/terms-of-use.",
        "title": "Terms of Use"
      }
    ],
    "publisher": {
      "category": "vendor",
      "contact_details": "productcert@siemens.com",
      "name": "Siemens ProductCERT",
      "namespace": "https://www.siemens.com"
    },
    "references": [
      {
        "category": "self",
        "summary": "SSA-634640: Weak Authentication Vulnerability in Siemens Industrial Edge Devices - HTML Version",
        "url": "https://cert-portal.siemens.com/productcert/html/ssa-634640.html"
      },
      {
        "category": "self",
        "summary": "SSA-634640: Weak Authentication Vulnerability in Siemens Industrial Edge Devices - CSAF Version",
        "url": "https://cert-portal.siemens.com/productcert/csaf/ssa-634640.json"
      }
    ],
    "title": "SSA-634640: Weak Authentication Vulnerability in Siemens Industrial Edge Devices",
    "tracking": {
      "current_release_date": "2025-07-08T00:00:00Z",
      "generator": {
        "engine": {
          "name": "Siemens ProductCERT CSAF Generator",
          "version": "1"
        }
      },
      "id": "SSA-634640",
      "initial_release_date": "2025-04-08T00:00:00Z",
      "revision_history": [
        {
          "date": "2025-04-08T00:00:00Z",
          "legacy_version": "1.0",
          "number": "1",
          "summary": "Publication Date"
        },
        {
          "date": "2025-07-08T00:00:00Z",
          "legacy_version": "1.1",
          "number": "2",
          "summary": "Added fix for SCALANCE LPE9413 (6GK5998-3GS01-2AC2)"
        }
      ],
      "status": "interim",
      "version": "2"
    }
  },
  "product_tree": {
    "branches": [
      {
        "branches": [
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "All versions \u003c V1.21.1-1-a",
                "product": {
                  "name": "Industrial Edge Own Device (IEOD)",
                  "product_id": "1"
                }
              }
            ],
            "category": "product_name",
            "name": "Industrial Edge Own Device (IEOD)"
          },
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "All versions \u003c V1.21.1-1-a",
                "product": {
                  "name": "Industrial Edge Virtual Device",
                  "product_id": "2"
                }
              }
            ],
            "category": "product_name",
            "name": "Industrial Edge Virtual Device"
          },
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "vers:all/\u003cV2.1",
                "product": {
                  "name": "SCALANCE LPE9413 (6GK5998-3GS01-2AC2)",
                  "product_id": "3",
                  "product_identification_helper": {
                    "model_numbers": [
                      "6GK5998-3GS01-2AC2"
                    ]
                  }
                }
              }
            ],
            "category": "product_name",
            "name": "SCALANCE LPE9413 (6GK5998-3GS01-2AC2)"
          },
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "vers:all/\u003cV3.0",
                "product": {
                  "name": "SIMATIC IPC127E Industrial Edge Device",
                  "product_id": "4"
                }
              }
            ],
            "category": "product_name",
            "name": "SIMATIC IPC127E Industrial Edge Device"
          },
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "vers:all/\u003cV3.0",
                "product": {
                  "name": "SIMATIC IPC227E Industrial Edge Device",
                  "product_id": "5"
                }
              }
            ],
            "category": "product_name",
            "name": "SIMATIC IPC227E Industrial Edge Device"
          },
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "vers:all/\u003cV3.0",
                "product": {
                  "name": "SIMATIC IPC427E Industrial Edge Device",
                  "product_id": "6"
                }
              }
            ],
            "category": "product_name",
            "name": "SIMATIC IPC427E Industrial Edge Device"
          },
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "vers:all/\u003cV3.0",
                "product": {
                  "name": "SIMATIC IPC847E Industrial Edge Device",
                  "product_id": "7"
                }
              }
            ],
            "category": "product_name",
            "name": "SIMATIC IPC847E Industrial Edge Device"
          },
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "vers:all/\u003cV3.0",
                "product": {
                  "name": "SIMATIC IPC BX-39A Industrial Edge Device",
                  "product_id": "8"
                }
              }
            ],
            "category": "product_name",
            "name": "SIMATIC IPC BX-39A Industrial Edge Device"
          },
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "vers:all/\u003cV3.0",
                "product": {
                  "name": "SIMATIC IPC BX-59A Industrial Edge Device",
                  "product_id": "9"
                }
              }
            ],
            "category": "product_name",
            "name": "SIMATIC IPC BX-59A Industrial Edge Device"
          }
        ],
        "category": "vendor",
        "name": "Siemens"
      }
    ]
  },
  "vulnerabilities": [
    {
      "cve": "CVE-2024-54092",
      "cwe": {
        "id": "CWE-1390",
        "name": "Weak Authentication"
      },
      "notes": [
        {
          "category": "summary",
          "text": "Affected devices do not properly enforce user authentication on specific API endpoints when identity federation is used. This could facilitate an unauthenticated remote attacker to circumvent authentication and impersonate a legitimate user. Successful exploitation requires that identity federation is currently or has previously been used and the attacker has learned the identity of a legitimate user.",
          "title": "Summary"
        }
      ],
      "product_status": {
        "known_affected": [
          "1",
          "2",
          "3",
          "4",
          "5",
          "6",
          "7",
          "8",
          "9"
        ]
      },
      "remediations": [
        {
          "category": "mitigation",
          "details": "Ensure network access to affected products is limited to trusted parties only",
          "product_ids": [
            "1",
            "2",
            "3",
            "4",
            "5",
            "6",
            "7",
            "8",
            "9"
          ]
        },
        {
          "category": "vendor_fix",
          "details": "Update to V1.21.1-1-a or later version",
          "product_ids": [
            "1"
          ],
          "url": "https://docs.industrial-operations-x.siemens.cloud/r/en-us/v25.02/industrial-edge-platform-operation-what-s-new/device-release-notes/release-notes-industrial-edge-own-device"
        },
        {
          "category": "vendor_fix",
          "details": "Update to V1.21.1-1-a or later version",
          "product_ids": [
            "2"
          ],
          "url": "https://docs.industrial-operations-x.siemens.cloud/r/en-us/v25.02/industrial-edge-platform-operation-what-s-new/device-release-notes/release-notes-industrial-edge-virtual-device"
        },
        {
          "category": "vendor_fix",
          "details": "Update to V2.1 or later version",
          "product_ids": [
            "3"
          ],
          "url": "https://docs.eu1.edge.siemens.cloud/release_notes/device_release_notes/LPE9413.html"
        },
        {
          "category": "vendor_fix",
          "details": "Update to V3.0 or later version",
          "product_ids": [
            "4",
            "5",
            "6",
            "7",
            "8",
            "9"
          ],
          "url": "https://docs.industrial-operations-x.siemens.cloud/r/en-us/v3.0/simatic-ipc-ied-os/release-notes"
        }
      ],
      "scores": [
        {
          "cvss_v3": {
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "products": [
            "1",
            "2",
            "3",
            "4",
            "5",
            "6",
            "7",
            "8",
            "9"
          ]
        }
      ],
      "title": "CVE-2024-54092"
    }
  ]
}



Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.

Sightings

Author Source Type Date Other

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.

Loading…

Detection rules are retrieved from Rulezet.

Loading…

Loading…

Related by attack behaviour

Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.


Loading…