SSA-563922

Vulnerability from csaf_siemens - Published: 2025-09-09 00:00 - Updated: 2026-10-13 00:00
Summary
SSA-563922: Local Privilege Escalation Vulnerability in SIMOTION Tools
Notes
Summary: Several tools for the SIMOTION system are affected by a local privilege escalation vulnerability. This could allow an attacker to execute arbitrary code with SYSTEM privileges when a legitimate user installs an application that uses the affected setup component. This vulnerability poses a risk only during setup and installation phase of the affected tools. Siemens has released a new version for SIMATIC Technology Package TPCamGen and recommends to update to the latest version. Siemens recommends specific mitigations for products where fixes are not or not yet available.
General Recommendations: As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens' operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals. Additional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity
Additional Resources: For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories
Terms of Use: The use of Siemens Security Advisories is subject to the terms and conditions listed on: https://www.siemens.com/productcert/terms-of-use.

Nullsoft Scriptable Install System (NSIS) before 3.11 on Windows allows local users to escalate privileges to SYSTEM during an installation, because the temporary plugins directory is created under %WINDIR%\temp and unprivileged users can place a crafted executable file by winning a race condition. This occurs because EW_CREATEDIR does not always set the CreateRestrictedDirectory error flag.

CWE-754 - Improper Check for Unusual or Exceptional Conditions
Affected products
Product Identifier Version Remediation
SIMATIC Technology Package TPCamGen (6ES7823-0FE30-1AA0) < V1.3.1
Siemens / SIMATIC Technology Package TPCamGen (6ES7823-0FE30-1AA0)
6ES7823-0FE30-1AA0 vers:intdot/<1.3.1
Mitigation
Vendor Fix
SIMOTION OA MIIF (6AU1820-3DA20-0AB0)
Siemens / SIMOTION OA MIIF (6AU1820-3DA20-0AB0)
6AU1820-3DA20-0AB0 vers:all/*
Mitigation
No Fix Planned
SIMOTION OACAMGEN (6AU1820-3EA20-0AB0)
Siemens / SIMOTION OACAMGEN (6AU1820-3EA20-0AB0)
6AU1820-3EA20-0AB0 vers:all/*
Mitigation
No Fix Planned
SIMOTION OALECO (6AU1820-3HA20-0AB0)
Siemens / SIMOTION OALECO (6AU1820-3HA20-0AB0)
6AU1820-3HA20-0AB0 vers:all/*
Mitigation
No Fix Planned
SIMOTION OAVIBX (6AU1820-3CA20-0AB0)
Siemens / SIMOTION OAVIBX (6AU1820-3CA20-0AB0)
6AU1820-3CA20-0AB0 vers:all/*
Mitigation
No Fix Planned

{
  "document": {
    "category": "csaf_security_advisory",
    "csaf_version": "2.0",
    "distribution": {
      "text": "Disclosure is not limited. (TLPv2: TLP:CLEAR)",
      "tlp": {
        "label": "WHITE"
      }
    },
    "lang": "en",
    "notes": [
      {
        "category": "summary",
        "text": "Several tools for the SIMOTION system are affected by a local privilege escalation vulnerability. This could allow an attacker to execute arbitrary code with SYSTEM privileges when a legitimate user installs an application that uses the affected setup component. This vulnerability poses a risk only during setup and installation phase of the affected tools.\n\nSiemens has released a new version for SIMATIC Technology Package TPCamGen and recommends to update to the latest version. Siemens recommends specific mitigations for products where fixes are not or not yet available.",
        "title": "Summary"
      },
      {
        "category": "general",
        "text": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity",
        "title": "General Recommendations"
      },
      {
        "category": "general",
        "text": "For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories",
        "title": "Additional Resources"
      },
      {
        "category": "legal_disclaimer",
        "text": "The use of Siemens Security Advisories is subject to the terms and conditions listed on: https://www.siemens.com/productcert/terms-of-use.",
        "title": "Terms of Use"
      }
    ],
    "publisher": {
      "category": "vendor",
      "contact_details": "productcert@siemens.com",
      "name": "Siemens ProductCERT",
      "namespace": "https://www.siemens.com"
    },
    "references": [
      {
        "category": "self",
        "summary": "SSA-563922: Local Privilege Escalation Vulnerability in SIMOTION Tools - HTML Version",
        "url": "https://cert-portal.siemens.com/productcert/html/ssa-563922.html"
      },
      {
        "category": "self",
        "summary": "SSA-563922: Local Privilege Escalation Vulnerability in SIMOTION Tools - CSAF Version",
        "url": "https://cert-portal.siemens.com/productcert/csaf/ssa-563922.json"
      }
    ],
    "title": "SSA-563922: Local Privilege Escalation Vulnerability in SIMOTION Tools",
    "tracking": {
      "current_release_date": "2026-10-13T00:00:00.000Z",
      "generator": {
        "engine": {
          "name": "Siemens ProductCERT CSAF Generator",
          "version": "1"
        }
      },
      "id": "SSA-563922",
      "initial_release_date": "2025-09-09T00:00:00.000Z",
      "revision_history": [
        {
          "date": "2025-09-09T00:00:00.000Z",
          "legacy_version": "1.0",
          "number": "1",
          "summary": "Publication Date"
        },
        {
          "date": "2026-10-13T00:00:00.000Z",
          "legacy_version": "1.1",
          "number": "2",
          "summary": "Added fix version for SIMATIC Technology Package TPCamGen"
        }
      ],
      "status": "final",
      "version": "2"
    }
  },
  "product_tree": {
    "branches": [
      {
        "branches": [
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "vers:intdot/\u003c1.3.1",
                "product": {
                  "name": "SIMATIC Technology Package TPCamGen (6ES7823-0FE30-1AA0) \u003c V1.3.1",
                  "product_id": "1",
                  "product_identification_helper": {
                    "model_numbers": [
                      "6ES7823-0FE30-1AA0"
                    ]
                  }
                }
              }
            ],
            "category": "product_name",
            "name": "SIMATIC Technology Package TPCamGen (6ES7823-0FE30-1AA0)"
          },
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "vers:all/*",
                "product": {
                  "name": "SIMOTION OA MIIF (6AU1820-3DA20-0AB0)",
                  "product_id": "2",
                  "product_identification_helper": {
                    "model_numbers": [
                      "6AU1820-3DA20-0AB0"
                    ]
                  }
                }
              }
            ],
            "category": "product_name",
            "name": "SIMOTION OA MIIF (6AU1820-3DA20-0AB0)"
          },
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "vers:all/*",
                "product": {
                  "name": "SIMOTION OACAMGEN (6AU1820-3EA20-0AB0)",
                  "product_id": "3",
                  "product_identification_helper": {
                    "model_numbers": [
                      "6AU1820-3EA20-0AB0"
                    ]
                  }
                }
              }
            ],
            "category": "product_name",
            "name": "SIMOTION OACAMGEN (6AU1820-3EA20-0AB0)"
          },
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "vers:all/*",
                "product": {
                  "name": "SIMOTION OALECO (6AU1820-3HA20-0AB0)",
                  "product_id": "4",
                  "product_identification_helper": {
                    "model_numbers": [
                      "6AU1820-3HA20-0AB0"
                    ]
                  }
                }
              }
            ],
            "category": "product_name",
            "name": "SIMOTION OALECO (6AU1820-3HA20-0AB0)"
          },
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "vers:all/*",
                "product": {
                  "name": "SIMOTION OAVIBX (6AU1820-3CA20-0AB0)",
                  "product_id": "5",
                  "product_identification_helper": {
                    "model_numbers": [
                      "6AU1820-3CA20-0AB0"
                    ]
                  }
                }
              }
            ],
            "category": "product_name",
            "name": "SIMOTION OAVIBX (6AU1820-3CA20-0AB0)"
          }
        ],
        "category": "vendor",
        "name": "Siemens"
      }
    ]
  },
  "vulnerabilities": [
    {
      "cve": "CVE-2025-43715",
      "cwe": {
        "id": "CWE-754",
        "name": "Improper Check for Unusual or Exceptional Conditions"
      },
      "notes": [
        {
          "category": "description",
          "text": "Nullsoft Scriptable Install System (NSIS) before 3.11 on Windows allows local users to escalate privileges to SYSTEM during an installation, because the temporary plugins directory is created under %WINDIR%\\temp and unprivileged users can place a crafted executable file by winning a race condition. This occurs because EW_CREATEDIR does not always set the CreateRestrictedDirectory error flag.",
          "title": "CVE Description"
        }
      ],
      "product_status": {
        "known_affected": [
          "1",
          "2",
          "3",
          "4",
          "5"
        ]
      },
      "remediations": [
        {
          "category": "mitigation",
          "details": "Ensure that no other users are logged in and that no unknown programs are running before starting the installation of the affected products",
          "product_ids": [
            "1",
            "2",
            "3",
            "4",
            "5"
          ]
        },
        {
          "category": "no_fix_planned",
          "details": "Currently no fix is planned",
          "product_ids": [
            "2",
            "3",
            "4",
            "5"
          ]
        },
        {
          "category": "vendor_fix",
          "details": "Update to V1.3.1 or later version\nTo obtain the patch and update information, please contact your regular Siemens contact person.",
          "product_ids": [
            "1"
          ]
        }
      ],
      "scores": [
        {
          "cvss_v3": {
            "baseScore": 8.1,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:L/AC:H/PR:N/UI:N/S:C/C:H/I:H/A:H",
            "version": "3.1"
          },
          "products": [
            "1",
            "2",
            "3",
            "4",
            "5"
          ]
        }
      ],
      "title": "CVE-2025-43715"
    }
  ]
}



Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Drag nodes to arrange them. Double-click a related vulnerability to open it, or a source to visit its link. The Physics button on the left tunes the layout and the simulation; the legend at the bottom left hides or shows nodes by kind and by sighting type.

Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.

Sightings

Author Source Type Date Other

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Vulnerability timeline

Sightings and recorded dates, grouped by day · UTC

JSON
Events included in the timeline

Loading timeline…


    Loading…

    Loading…

    Loading…

    Related by attack behaviour

    Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.