SSA-547714

Vulnerability from csaf_siemens - Published: 2022-12-13 00:00 - Updated: 2023-01-10 00:00
Summary
SSA-547714: Argument Injection Vulnerability in SIMATIC WinCC OA Ultralight Client
Notes
Summary: SIMATIC WinCC OA contains an argument injection vulnerability that could allow an authenticated remote attacker to inject arbitrary parameters, when starting the Ultralight Client via the web interface (e.g., open attacker chosen panels with the attacker's credentials or start a Ctrl script). Siemens has released updates for several affected products and recommends to update to the latest versions. Siemens is preparing further updates and recommends specific countermeasures for products where updates are not, or not yet available.
General Recommendations: As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens' operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals. Additional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity
Additional Resources: For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories
Terms of Use: Siemens Security Advisories are subject to the terms and conditions contained in Siemens' underlying license terms or other applicable agreements previously agreed to with Siemens (hereinafter "License Terms"). To the extent applicable to information, software or documentation made available in or through a Siemens Security Advisory, the Terms of Use of Siemens' Global Website (https://www.siemens.com/terms_of_use, hereinafter "Terms of Use"), in particular Sections 8-10 of the Terms of Use, shall apply additionally. In case of conflicts, the License Terms shall prevail over the Terms of Use.
CWE-88 - Improper Neutralization of Argument Delimiters in a Command ('Argument Injection')
Affected products
Product Identifier Version Remediation
SIMATIC WinCC OA V3.15
Siemens / SIMATIC WinCC OA V3.15
< V3.15 P038
Mitigation
Vendor Fix fix
SIMATIC WinCC OA V3.16
Siemens / SIMATIC WinCC OA V3.16
< V3.16 P035
Mitigation
Vendor Fix fix
SIMATIC WinCC OA V3.17
Siemens / SIMATIC WinCC OA V3.17
< V3.17 P024
Mitigation
Vendor Fix fix
SIMATIC WinCC OA V3.18
Siemens / SIMATIC WinCC OA V3.18
< V3.18 P014
Mitigation
Vendor Fix fix

{
  "document": {
    "category": "csaf_security_advisory",
    "csaf_version": "2.0",
    "distribution": {
      "text": "Disclosure is not limited. (TLPv2: TLP:CLEAR)",
      "tlp": {
        "label": "WHITE"
      }
    },
    "notes": [
      {
        "category": "summary",
        "text": "SIMATIC WinCC OA contains an argument injection vulnerability that could allow an authenticated remote attacker to inject arbitrary parameters, when starting the Ultralight Client via the web interface (e.g., open attacker chosen panels with the attacker\u0027s credentials or start a Ctrl script).\n\nSiemens has released updates for several affected products and recommends to update to the latest versions. Siemens is preparing further updates and recommends specific countermeasures for products where updates are not, or not yet available.",
        "title": "Summary"
      },
      {
        "category": "general",
        "text": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity",
        "title": "General Recommendations"
      },
      {
        "category": "general",
        "text": "For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories",
        "title": "Additional Resources"
      },
      {
        "category": "legal_disclaimer",
        "text": "Siemens Security Advisories are subject to the terms and conditions contained in Siemens\u0027 underlying license terms or other applicable agreements previously agreed to with Siemens (hereinafter \"License Terms\"). To the extent applicable to information, software or documentation made available in or through a Siemens Security Advisory, the Terms of Use of Siemens\u0027 Global Website (https://www.siemens.com/terms_of_use, hereinafter \"Terms of Use\"), in particular Sections 8-10 of the Terms of Use, shall apply additionally. In case of conflicts, the License Terms shall prevail over the Terms of Use.",
        "title": "Terms of Use"
      }
    ],
    "publisher": {
      "category": "vendor",
      "contact_details": "productcert@siemens.com",
      "name": "Siemens ProductCERT",
      "namespace": "https://www.siemens.com"
    },
    "references": [
      {
        "category": "self",
        "summary": "SSA-547714: Argument Injection Vulnerability in SIMATIC WinCC OA Ultralight Client - PDF Version",
        "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-547714.pdf"
      },
      {
        "category": "self",
        "summary": "SSA-547714: Argument Injection Vulnerability in SIMATIC WinCC OA Ultralight Client - TXT Version",
        "url": "https://cert-portal.siemens.com/productcert/txt/ssa-547714.txt"
      },
      {
        "category": "self",
        "summary": "SSA-547714: Argument Injection Vulnerability in SIMATIC WinCC OA Ultralight Client - CSAF Version",
        "url": "https://cert-portal.siemens.com/productcert/csaf/ssa-547714.json"
      }
    ],
    "title": "SSA-547714: Argument Injection Vulnerability in SIMATIC WinCC OA Ultralight Client",
    "tracking": {
      "current_release_date": "2023-01-10T00:00:00Z",
      "generator": {
        "engine": {
          "name": "Siemens ProductCERT CSAF Generator",
          "version": "1"
        }
      },
      "id": "SSA-547714",
      "initial_release_date": "2022-12-13T00:00:00Z",
      "revision_history": [
        {
          "date": "2022-12-13T00:00:00Z",
          "legacy_version": "1.0",
          "number": "1",
          "summary": "Publication Date"
        },
        {
          "date": "2023-01-10T00:00:00Z",
          "legacy_version": "1.1",
          "number": "2",
          "summary": "Added fix for SIMATIC WinCC OA V3.15"
        }
      ],
      "status": "final",
      "version": "2"
    }
  },
  "product_tree": {
    "branches": [
      {
        "branches": [
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "\u003c V3.15 P038",
                "product": {
                  "name": "SIMATIC WinCC OA V3.15",
                  "product_id": "1"
                }
              }
            ],
            "category": "product_name",
            "name": "SIMATIC WinCC OA V3.15"
          },
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "\u003c V3.16 P035",
                "product": {
                  "name": "SIMATIC WinCC OA V3.16",
                  "product_id": "2"
                }
              }
            ],
            "category": "product_name",
            "name": "SIMATIC WinCC OA V3.16"
          },
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "\u003c V3.17 P024",
                "product": {
                  "name": "SIMATIC WinCC OA V3.17",
                  "product_id": "3"
                }
              }
            ],
            "category": "product_name",
            "name": "SIMATIC WinCC OA V3.17"
          },
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "\u003c V3.18 P014",
                "product": {
                  "name": "SIMATIC WinCC OA V3.18",
                  "product_id": "4"
                }
              }
            ],
            "category": "product_name",
            "name": "SIMATIC WinCC OA V3.18"
          }
        ],
        "category": "vendor",
        "name": "Siemens"
      }
    ]
  },
  "vulnerabilities": [
    {
      "cve": "CVE-2022-44731",
      "cwe": {
        "id": "CWE-88",
        "name": "Improper Neutralization of Argument Delimiters in a Command (\u0027Argument Injection\u0027)"
      },
      "notes": [
        {
          "category": "summary",
          "text": "The affected component allows to inject custom arguments to the Ultralight Client backend application under certain circumstances.\r\n\r\nThis could allow an authenticated remote attacker to inject arbitrary parameters when starting the client via the web interface (e.g., open attacker chosen panels with the attacker\u0027s credentials or start a Ctrl script).",
          "title": "Summary"
        }
      ],
      "product_status": {
        "known_affected": [
          "1",
          "2",
          "3",
          "4"
        ]
      },
      "remediations": [
        {
          "category": "mitigation",
          "details": "Configure user permissions and access management according to the WinCC OA Security Guideline: \nhttps://www.winccoa.com/documentation/WinCCOA/3.18/en_US/UserAdmin/security.html",
          "product_ids": [
            "1",
            "2",
            "3",
            "4"
          ]
        },
        {
          "category": "vendor_fix",
          "details": "Update to V3.15 P038 or later version",
          "product_ids": [
            "1"
          ],
          "url": "https://www.winccoa.com/downloads/category/versions-patches.html"
        },
        {
          "category": "vendor_fix",
          "details": "Update to V3.16 P035 or later version",
          "product_ids": [
            "2"
          ],
          "url": "https://www.winccoa.com/downloads/category/versions-patches.html"
        },
        {
          "category": "vendor_fix",
          "details": "Update to V3.17 P024 or later version",
          "product_ids": [
            "3"
          ],
          "url": "https://www.winccoa.com/downloads/category/versions-patches.html"
        },
        {
          "category": "vendor_fix",
          "details": "Update to V3.18 P014 or later version",
          "product_ids": [
            "4"
          ],
          "url": "https://www.winccoa.com/downloads/category/versions-patches.html"
        }
      ],
      "scores": [
        {
          "cvss_v3": {
            "baseScore": 5.4,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:N/E:P/RL:O/RC:C",
            "version": "3.1"
          },
          "products": [
            "1",
            "2",
            "3",
            "4"
          ]
        }
      ],
      "title": "CVE-2022-44731"
    }
  ]
}



Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Drag nodes to arrange them. Double-click a related vulnerability to open it, or a source to visit its link. The Physics button on the left tunes the layout and the simulation; the legend at the bottom left hides or shows nodes by kind and by sighting type.

Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.

Sightings

Author Source Type Date Other

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Vulnerability timeline

Sightings and recorded dates, grouped by day · UTC

JSON
How durations are calculated

Following the VTEM framework (Black Hat USA 2015), time to patch starts when the vendor or a coordinator was informed, total time to patch at discovery, and disclosure to patch at public disclosure; vendor response time runs from the report to its acknowledgement. Time to exploit and time unpatched start at the earliest discovery or report, falling back to public disclosure. Unpatched time ends at the first recorded patch, or the calculation time when no patch is recorded. Exploitation to patch shows the interval between those two events; a published proof of concept is a public exploit, not exploitation.

Each result shows its source dates. A negative interval means the end event came first; when date-only inputs leave the order open, the result says so. Date-only inputs are approximate. The earliest evidence wins: KEV report dates and sightings are labelled as such. Records describing another vulnerability are listed but never calculated from, and a PoC alone does not establish exploitation. Missing patch evidence does not prove that no patch exists. Filters below change the event list only.

Events included in the timeline

Loading timeline…


    Loading…

    Loading…

    Loading…

    Related by attack behaviour

    Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.