SSA-514895
Vulnerability from csaf_siemens - Published: 2025-11-11 00:00 - Updated: 2025-11-11 00:00Summary
SSA-514895: Multiple Vulnerabilities in Altair Grid Engine V2025.1.0
Notes
Summary: Altair Grid Engine contain multiple vulnerabilities that could allow an attacker to escalate privileges and execute arbitrary code with superuser permissions.
Siemens has released a new version for Altair Grid Engine and recommends to update to the latest version.
General Recommendations: As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens' operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.
Additional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity
Additional Resources: For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories
Terms of Use: The use of Siemens Security Advisories is subject to the terms and conditions listed on: https://www.siemens.com/productcert/terms-of-use.
7.8 (High)
Affected products
Known affected
1 product, the same list as for
CVE-2025-40760
References
2 references
{
"document": {
"category": "csaf_security_advisory",
"csaf_version": "2.0",
"distribution": {
"text": "Disclosure is not limited. (TLPv2: TLP:CLEAR)",
"tlp": {
"label": "WHITE"
}
},
"lang": "en",
"notes": [
{
"category": "summary",
"text": "Altair Grid Engine contain multiple vulnerabilities that could allow an attacker to escalate privileges and execute arbitrary code with superuser permissions.\nSiemens has released a new version for Altair Grid Engine and recommends to update to the latest version.",
"title": "Summary"
},
{
"category": "general",
"text": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity",
"title": "General Recommendations"
},
{
"category": "general",
"text": "For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories",
"title": "Additional Resources"
},
{
"category": "legal_disclaimer",
"text": "The use of Siemens Security Advisories is subject to the terms and conditions listed on: https://www.siemens.com/productcert/terms-of-use.",
"title": "Terms of Use"
}
],
"publisher": {
"category": "vendor",
"contact_details": "productcert@siemens.com",
"name": "Siemens ProductCERT",
"namespace": "https://www.siemens.com"
},
"references": [
{
"category": "self",
"summary": "SSA-514895: Multiple Vulnerabilities in Altair Grid Engine V2025.1.0 - HTML Version",
"url": "https://cert-portal.siemens.com/productcert/html/ssa-514895.html"
},
{
"category": "self",
"summary": "SSA-514895: Multiple Vulnerabilities in Altair Grid Engine V2025.1.0 - CSAF Version",
"url": "https://cert-portal.siemens.com/productcert/csaf/ssa-514895.json"
}
],
"title": "SSA-514895: Multiple Vulnerabilities in Altair Grid Engine V2025.1.0",
"tracking": {
"current_release_date": "2025-11-11T00:00:00Z",
"generator": {
"engine": {
"name": "Siemens ProductCERT CSAF Generator",
"version": "1"
}
},
"id": "SSA-514895",
"initial_release_date": "2025-11-11T00:00:00Z",
"revision_history": [
{
"date": "2025-11-11T00:00:00Z",
"legacy_version": "1.0",
"number": "1",
"summary": "Publication Date"
}
],
"status": "interim",
"version": "1"
}
},
"product_tree": {
"branches": [
{
"branches": [
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c2026.0.0",
"product": {
"name": "Altair Grid Engine",
"product_id": "1"
}
}
],
"category": "product_name",
"name": "Altair Grid Engine"
}
],
"category": "vendor",
"name": "Siemens"
}
]
},
"vulnerabilities": [
{
"cve": "CVE-2025-40760",
"cwe": {
"id": "CWE-209",
"name": "Generation of Error Message Containing Sensitive Information"
},
"notes": [
{
"category": "summary",
"text": "Affected products do not properly handle error messages and discloses sensitive password hash information when processing user authentication requests.\r\nThis could allow a local attacker to extract password hashes for privileged accounts, which can then be subjected to offline brute-force attacks.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"1"
]
},
"remediations": [
{
"category": "mitigation",
"details": "For clusters not using the UGERest API/daemon remove the setuid-root bit from the binaries for all architectures: chmod u-s $SGE_ROOT/utilbin/\u0026lt;arch\u0026gt;/authuser.",
"product_ids": [
"1"
]
},
{
"category": "vendor_fix",
"details": "Update to V2026.0.0 or later version",
"product_ids": [
"1"
],
"url": "https://altairone.com/Marketplace"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 5.5,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
},
"products": [
"1"
]
}
],
"title": "CVE-2025-40760"
},
{
"cve": "CVE-2025-40763",
"cwe": {
"id": "CWE-427",
"name": "Uncontrolled Search Path Element"
},
"notes": [
{
"category": "summary",
"text": "Affected products do not properly validate environment variables when loading shared libraries, allowing path hijacking through malicious library substitution.\r\nThis could allow a local attacker to execute arbitrary code with superuser privileges by manipulating the environment variable and placing a malicious library in the controlled path.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"1"
]
},
"remediations": [
{
"category": "mitigation",
"details": "For non Windows clusters remove the setuid-root bit from the \"sgepasswd\" binary for all installed architectures: chmod u-s $SGE_ROOT/bin/\u0026lt;arch\u0026gt;/sgepasswd.",
"product_ids": [
"1"
]
},
{
"category": "vendor_fix",
"details": "Update to V2026.0.0 or later version",
"product_ids": [
"1"
],
"url": "https://altairone.com/Marketplace"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"products": [
"1"
]
}
],
"title": "CVE-2025-40763"
}
]
}
Loading…
Loading…
Drag nodes to arrange them. Double-click a related vulnerability to open it, or a source to visit its link. The Physics button on the left tunes the layout and the simulation; the legend at the bottom left hides or shows nodes by kind and by sighting type.
Experimental. This forecast is provided for visualization only and may change without notice. Do not use it for operational decisions.
Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.
Sightings
| Author | Source | Type | Date | Other |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Vulnerability timeline
Sightings and recorded dates, grouped by day · UTC
Loading timeline…
Loading…
Loading…
The MITRE ATT&CK techniques below are AI-generated suggestions, inferred from the description of the
vulnerability by the CIRCL/vulnerability-attack-technique-classification-roberta-base
model, served locally by ML-Gateway.
They have not been verified by an analyst and are provided for guidance only.
The approach is described in our paper Mapping CVEs to MITRE ATT&CK Techniques: A Curated Gold-Set Classifier and the Limits of LLM-Assisted Label Expansion.
Browse all ATT&CK techniques and the vulnerabilities related to each.
The approach is described in our paper Mapping CVEs to MITRE ATT&CK Techniques: A Curated Gold-Set Classifier and the Limits of LLM-Assisted Label Expansion.
Browse all ATT&CK techniques and the vulnerabilities related to each.
Loading…
Related by attack behaviour
Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.