SSA-250085
Vulnerability from csaf_siemens - Published: 2022-03-08 00:00 - Updated: 2023-10-10 00:00| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
SINEC NMS
Siemens / SINEC NMS
|
<V1.0.3 |
Mitigation
Vendor Fix
fix
|
|
|
SINEMA Server V14
Siemens / SINEMA Server V14
|
vers:all/* |
Mitigation
No Fix Planned
|
{
"document": {
"category": "csaf_security_advisory",
"csaf_version": "2.0",
"distribution": {
"text": "Disclosure is not limited. (TLPv2: TLP:CLEAR)",
"tlp": {
"label": "WHITE"
}
},
"lang": "en",
"notes": [
{
"category": "summary",
"text": "SINEC NMS and SINEMA Server V14 contain multiple vulnerabilities that could allow an attacker to execute arbitrary code on the system, arbitrary commands on the local database or achieve privilege escalation. \n\nSiemens has released several updates for SINEC NMS and recommends to update to the latest version. Siemens recommends specific countermeasures for products where updates are not, or not yet available.",
"title": "Summary"
},
{
"category": "general",
"text": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity",
"title": "General Recommendations"
},
{
"category": "general",
"text": "For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories",
"title": "Additional Resources"
},
{
"category": "legal_disclaimer",
"text": "Siemens Security Advisories are subject to the terms and conditions contained in Siemens\u0027 underlying license terms or other applicable agreements previously agreed to with Siemens (hereinafter \"License Terms\"). To the extent applicable to information, software or documentation made available in or through a Siemens Security Advisory, the Terms of Use of Siemens\u0027 Global Website (https://www.siemens.com/terms_of_use, hereinafter \"Terms of Use\"), in particular Sections 8-10 of the Terms of Use, shall apply additionally. In case of conflicts, the License Terms shall prevail over the Terms of Use.",
"title": "Terms of Use"
}
],
"publisher": {
"category": "vendor",
"contact_details": "productcert@siemens.com",
"name": "Siemens ProductCERT",
"namespace": "https://www.siemens.com"
},
"references": [
{
"category": "self",
"summary": "SSA-250085: Multiple Vulnerabilities in SINEC NMS and SINEMA Server - HTML Version",
"url": "https://cert-portal.siemens.com/productcert/html/ssa-250085.html"
},
{
"category": "self",
"summary": "SSA-250085: Multiple Vulnerabilities in SINEC NMS and SINEMA Server - CSAF Version",
"url": "https://cert-portal.siemens.com/productcert/csaf/ssa-250085.json"
},
{
"category": "self",
"summary": "SSA-250085: Multiple Vulnerabilities in SINEC NMS and SINEMA Server - PDF Version",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-250085.pdf"
},
{
"category": "self",
"summary": "SSA-250085: Multiple Vulnerabilities in SINEC NMS and SINEMA Server - TXT Version",
"url": "https://cert-portal.siemens.com/productcert/txt/ssa-250085.txt"
}
],
"title": "SSA-250085: Multiple Vulnerabilities in SINEC NMS and SINEMA Server",
"tracking": {
"current_release_date": "2023-10-10T00:00:00Z",
"generator": {
"engine": {
"name": "Siemens ProductCERT CSAF Generator",
"version": "1"
}
},
"id": "SSA-250085",
"initial_release_date": "2022-03-08T00:00:00Z",
"revision_history": [
{
"date": "2022-03-08T00:00:00Z",
"legacy_version": "1.0",
"number": "1",
"summary": "Publication Date"
},
{
"date": "2022-10-11T00:00:00Z",
"legacy_version": "1.1",
"number": "2",
"summary": "Added fix for CVE-2022-24281 in SINEC NMS V1.0.3"
},
{
"date": "2023-03-14T00:00:00Z",
"legacy_version": "1.2",
"number": "3",
"summary": "Added SINEMA Server V14 to the list of affected products"
},
{
"date": "2023-10-10T00:00:00Z",
"legacy_version": "1.3",
"number": "4",
"summary": "Added fix for remaining vulnerabilities in SINEC NMS V2.0"
}
],
"status": "interim",
"version": "4"
}
},
"product_tree": {
"branches": [
{
"branches": [
{
"branches": [
{
"category": "product_version_range",
"name": "\u003cV1.0.3",
"product": {
"name": "SINEC NMS",
"product_id": "1"
}
},
{
"category": "product_version_range",
"name": "\u003e=V1.0.3\u003cV2.0",
"product": {
"name": "SINEC NMS",
"product_id": "2"
}
}
],
"category": "product_name",
"name": "SINEC NMS"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SINEMA Server V14",
"product_id": "3"
}
}
],
"category": "product_name",
"name": "SINEMA Server V14"
}
],
"category": "vendor",
"name": "Siemens"
}
]
},
"vulnerabilities": [
{
"cve": "CVE-2022-24281",
"cwe": {
"id": "CWE-89",
"name": "Improper Neutralization of Special Elements used in an SQL Command (\u0027SQL Injection\u0027)"
},
"notes": [
{
"category": "summary",
"text": "A privileged authenticated attacker could execute arbitrary commands in the local database by sending specially crafted requests to the webserver of the affected application.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"1",
"3"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Restrict access to the affected systems, especially to port 443/tcp, to trusted IP addresses only",
"product_ids": [
"1",
"3"
]
},
{
"category": "no_fix_planned",
"details": "Currently no fix is planned",
"product_ids": [
"3"
]
},
{
"category": "vendor_fix",
"details": "Update to V1.0.3 or later version",
"product_ids": [
"1"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109813788/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.2,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"1",
"3"
]
}
],
"title": "CVE-2022-24281"
},
{
"cve": "CVE-2022-24282",
"cwe": {
"id": "CWE-502",
"name": "Deserialization of Untrusted Data"
},
"notes": [
{
"category": "summary",
"text": "The affected system allows to upload JSON objects that are deserialized to Java objects. Due to insecure deserialization of user-supplied content by the affected software, a privileged attacker could exploit this vulnerability by sending a maliciously crafted serialized Java object. This could allow the attacker to execute arbitrary code on the device with root privileges.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"2",
"1",
"3"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Restrict access to the affected systems, especially to port 443/tcp, to trusted IP addresses only",
"product_ids": [
"2",
"1",
"3"
]
},
{
"category": "no_fix_planned",
"details": "Currently no fix is planned",
"product_ids": [
"3"
]
},
{
"category": "vendor_fix",
"details": "Update to V1.0.3 or later version",
"product_ids": [
"1"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109813788/"
},
{
"category": "vendor_fix",
"details": "Update to V2.0 or later version",
"product_ids": [
"2"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109824030/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.2,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H/E:P/RL:T/RC:C",
"version": "3.1"
},
"products": [
"2",
"1",
"3"
]
}
],
"title": "CVE-2022-24282"
},
{
"cve": "CVE-2022-25311",
"cwe": {
"id": "CWE-269",
"name": "Improper Privilege Management"
},
"notes": [
{
"category": "summary",
"text": "The affected software do not properly check privileges between users during the same web browser session, creating an unintended sphere of control. This could allow an authenticated low privileged user to achieve privilege escalation.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"2",
"1",
"3"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Restrict access to the affected systems, especially to port 443/tcp, to trusted IP addresses only",
"product_ids": [
"2",
"1",
"3"
]
},
{
"category": "no_fix_planned",
"details": "Currently no fix is planned",
"product_ids": [
"3"
]
},
{
"category": "vendor_fix",
"details": "Update to V1.0.3 or later version",
"product_ids": [
"1"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109813788/"
},
{
"category": "vendor_fix",
"details": "Update to V2.0 or later version",
"product_ids": [
"2"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109824030/"
},
{
"category": "workaround",
"details": "CVE-2022-25311: If SSO was established and user is authenticated in both Control and Operation, it is recommended to logout explicitly in both Control and Operation to avoid privilege escalation",
"product_ids": [
"2",
"1",
"3"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.3,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:H/E:P/RL:T/RC:C",
"version": "3.1"
},
"products": [
"2",
"1",
"3"
]
}
],
"title": "CVE-2022-25311"
}
]
}
Drag nodes to arrange them. Double-click a related vulnerability to open it, or a source to visit its link. The Physics button on the left tunes the layout and the simulation; the legend at the bottom left hides or shows nodes by kind and by sighting type.
Sightings
| Author | Source | Type | Date | Other |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Vulnerability timeline
Sightings and recorded dates, grouped by day · UTC
How durations are calculated
Following the VTEM framework (Black Hat USA 2015), time to patch starts when the vendor or a coordinator was informed, total time to patch at discovery, and disclosure to patch at public disclosure; vendor response time runs from the report to its acknowledgement. Time to exploit and time unpatched start at the earliest discovery or report, falling back to public disclosure. Unpatched time ends at the first recorded patch, or the calculation time when no patch is recorded. Exploitation to patch shows the interval between those two events; a published proof of concept is a public exploit, not exploitation.
Each result shows its source dates. A negative interval means the end event came first; when date-only inputs leave the order open, the result says so. Date-only inputs are approximate. The earliest evidence wins: KEV report dates and sightings are labelled as such. Records describing another vulnerability are listed but never calculated from, and a PoC alone does not establish exploitation. Missing patch evidence does not prove that no patch exists. Filters below change the event list only.
Loading timeline…
The approach is described in our paper Mapping CVEs to MITRE ATT&CK Techniques: A Curated Gold-Set Classifier and the Limits of LLM-Assisted Label Expansion.
Browse all ATT&CK techniques and the vulnerabilities related to each.
Related by attack behaviour
Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.