SCA-2026-0007
Vulnerability from csaf_sick - Published: 2026-04-21 13:00 - Updated: 2026-04-21 13:00Sudo before 1.9.17p1 allows local users to obtain root access because /etc/nsswitch.conf from a user-controlled directory is used with the --chroot option.
| Product | Identifier | Version | Remediation |
|---|---|---|---|
| Unresolved product id: CSAFPID-32001 | — |
| Product | Identifier | Version | Remediation |
|---|---|---|---|
| Unresolved product id: CSAFPID-31001 | — |
Vendor Fix
|
{
"document": {
"category": "csaf_security_advisory",
"csaf_version": "2.0",
"distribution": {
"tlp": {
"label": "WHITE",
"url": "https://www.first.org/tlp/"
}
},
"lang": "en-US",
"notes": [
{
"category": "summary",
"text": "The display unit of the Endress+Hauser MCS200HW is affected by a sudo chroot vulnerability.",
"title": "Summary"
},
{
"category": "description",
"text": "If exploited, this vulnerability could potentially allow an unauthenticated attacker to compromise the availability, integrity, and confidentiality of the Endress+Hauser MCS200HW.",
"title": "Impact"
},
{
"category": "description",
"text": "As general security measures, SICK recommends minimizing network exposure of the devices, restricting network access, and following recommended security practices in order to operate the devices in a protected IT environment.",
"title": "Mitigation"
},
{
"category": "description",
"text": "SICK recommends updating the display unit of the product to version 4.3.4 and ensuring that the product operates within a secure environment.",
"title": "Remediation"
},
{
"category": "general",
"text": "As general security measures, SICK recommends minimizing network exposure of the devices, restricting network access, and following recommended security practices in order to operate the devices in a protected IT environment.",
"title": "General Recommendation"
}
],
"publisher": {
"category": "coordinator",
"contact_details": "psirt@sick.de",
"issuing_authority": "SICK AG issues and issues in EHS products (when related to the Endress+Hauser SICK (EHS) joint venture).",
"name": "SICK PSIRT",
"namespace": "https://www.sick.com/psirt"
},
"references": [
{
"category": "external",
"summary": "Endress+Hauser",
"url": "https://www.endress.com"
},
{
"summary": "SICK PSIRT Security Advisories",
"url": "https://www.sick.com/psirt"
},
{
"category": "external",
"summary": "ICS-CERT recommended practices on Industrial Security",
"url": "https://www.cisa.gov/resources-tools/resources/ics-recommended-practices"
},
{
"category": "external",
"summary": "CVSS v3.1 Calculator",
"url": "https://www.first.org/cvss/calculator/3.1"
},
{
"category": "self",
"summary": "The canonical URL.",
"url": "https://www.sick.com/.well-known/csaf/white/2026/sca-2026-0007.json"
},
{
"summary": "Standalone display firmware, update procedure and further details",
"url": "https://www.phoenixcontact.com/de-de/produkte/touch-panel-wp-6121-wxps-1290802"
}
],
"title": "Sudo vulnerability affects Endress+Hauser MCS200HW",
"tracking": {
"aliases": [
"SCA-2026-0007"
],
"current_release_date": "2026-04-21T13:00:00.000Z",
"generator": {
"date": "2026-04-21T07:51:46.425Z",
"engine": {
"name": "Secvisogram",
"version": "2.5.47"
}
},
"id": "SCA-2026-0007",
"initial_release_date": "2026-04-21T13:00:00.000Z",
"revision_history": [
{
"date": "2026-04-21T13:00:00.000Z",
"number": "1.0.0",
"summary": "Initial version"
}
],
"status": "final",
"version": "1.0.0"
}
},
"product_tree": {
"branches": [
{
"branches": [
{
"branches": [
{
"branches": [
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "Endress+Hauser MCS200HW all versions",
"product_id": "CSAFPID-11001"
}
}
],
"category": "product_name",
"name": "MCS200HW"
}
],
"category": "product_family",
"name": "Extractive Analyzer"
}
],
"category": "product_family",
"name": "Hardware"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c1.11.5.6R",
"product": {
"name": "Firmware \u003c1.11.5.6R",
"product_id": "CSAFPID-21001"
}
},
{
"category": "product_version",
"name": "1.11.5.6R",
"product": {
"name": "Firmware 1.11.5.6R",
"product_id": "CSAFPID-22001"
}
}
],
"category": "product_family",
"name": "Firmware"
}
],
"category": "vendor",
"name": "Endress+Hauser"
}
],
"relationships": [
{
"category": "installed_on",
"full_product_name": {
"name": "Endress+Hauser MCS200HW with firmware \u003c1.11.5.6R",
"product_id": "CSAFPID-31001"
},
"product_reference": "CSAFPID-21001",
"relates_to_product_reference": "CSAFPID-11001"
},
{
"category": "installed_on",
"full_product_name": {
"name": "Endress+Hauser MCS200HW with firmware 1.11.5.6R",
"product_id": "CSAFPID-32001"
},
"product_reference": "CSAFPID-22001",
"relates_to_product_reference": "CSAFPID-11001"
}
]
},
"vulnerabilities": [
{
"cve": "CVE-2025-32463",
"cwe": {
"id": "CWE-829",
"name": "Inclusion of Functionality from Untrusted Control Sphere"
},
"notes": [
{
"audience": "all",
"category": "description",
"text": "Sudo before 1.9.17p1 allows local users to obtain root access because /etc/nsswitch.conf from a user-controlled directory is used with the --chroot option.",
"title": "Vulnerability Description"
}
],
"product_status": {
"fixed": [
"CSAFPID-32001"
],
"known_affected": [
"CSAFPID-31001"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "The display unit\u0027s firmware versions below 4.3.4 are affected. To address the vulnerability, customers are strongly recommended to update the display unit of their devices to firmware version 4.3.4.\n\nEndress+Hauser will include this firmware version in the MCS200HW products starting with version 1.11.5.6R.\n\nAlternatively, customers can contact Endress+Hauser directly to obtain the updated display firmware, or download the original firmware - including update instructions - from the Phoenix\u00a0Contact website referenced below.",
"product_ids": [
"CSAFPID-31001"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 9.3,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"environmentalScore": 9.4,
"environmentalSeverity": "CRITICAL",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "CHANGED",
"temporalScore": 9.3,
"temporalSeverity": "CRITICAL",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H",
"version": "3.1"
},
"products": [
"CSAFPID-31001"
]
}
],
"title": "CVE-2025-32463"
}
]
}
Drag nodes to arrange them. Double-click a related vulnerability to open it, or a source to visit its link. The Physics button on the left tunes the layout and the simulation; the legend at the bottom left hides or shows nodes by kind and by sighting type.
Sightings
| Author | Source | Type | Date | Other |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Vulnerability timeline
Sightings and recorded dates, grouped by day · UTC
How durations are calculated
Following the VTEM framework (Black Hat USA 2015), time to patch starts when the vendor or a coordinator was informed, total time to patch at discovery, and disclosure to patch at public disclosure; vendor response time runs from the report to its acknowledgement. Time to exploit and time unpatched start at the earliest discovery or report, falling back to public disclosure. Unpatched time ends at the first recorded patch, or the calculation time when no patch is recorded. Exploitation to patch shows the interval between those two events; a published proof of concept is a public exploit, not exploitation. The method is described in a publication.
Each result shows its source dates. A negative interval means the end event came first; when date-only inputs leave the order open, the result says so. Date-only inputs are approximate. The earliest evidence wins: KEV report dates and sightings are labelled as such. Records describing another vulnerability are listed but never calculated from, and a PoC alone does not establish exploitation. Missing patch evidence does not prove that no patch exists. Filters below change the event list only.
Loading timeline…
The approach is described in our paper Mapping CVEs to MITRE ATT&CK Techniques: A Curated Gold-Set Classifier and the Limits of LLM-Assisted Label Expansion.
Browse all ATT&CK techniques and the vulnerabilities related to each.
Related by attack behaviour
Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.