SCA-2021-0001

Vulnerability from csaf_sick - Published: 2021-06-26 10:00 - Updated: 2026-11-13 15:18
Summary
Inadequate SSH configuration in SICK Visionary-S CX
Notes
SICK received a report that informed SICK about an Inadequate Encryption Strength vulnerability in the SICK product “SICK Visionary-S CX” concerning the internal SSH interface solely used by SICK for recovering returned devices. Currently SICK is not aware of any public exploits specifically targeting this vulnerability.
The vulnerability is not visible in any supported customer functionality. Thus customers can only identify products by firmware version. Accessing the device via SSH now shows OpenSSH instead of dropbear.
General Security Measures: As general security measures, SICK recommends to minimize network exposure of the devices, restrict network access and follow recommended security practices in order to run the devices in a protected IT environment.
Vulnerability Classification: SICK performs vulnerability classification by using the CVSS scoring system (*CVSS v3.1*). The environmental score is dependent on the customer’s environment and can affect the overall CVSS score. SICK recommends that customers individually evaluate the environmental score to achieve final scoring.

The use of weak algorithms makes it easier for an attacker to break the security that protects information transmitted from the client to the SSH server, assuming the attacker has access to the network on which the device is connected. This can increase the risk that encryption will be compromised, leading to the exposure of sensitive user information and man-in-the-middle attacks. SICK has developed a hotfix. In released firmware versions greater than 5.21.2.29154 the SSH server will no longer offer these weak ciphers.

CWE-326 - Inadequate Encryption Strength
Affected products
Product Identifier Version Remediation
Unresolved product id: CSAFPID-0005 —
Product Identifier Version Remediation
Unresolved product id: CSAFPID-0004 —
Vendor Fix

{
  "document": {
    "category": "csaf_security_advisory",
    "csaf_version": "2.0",
    "distribution": {
      "tlp": {
        "label": "WHITE",
        "url": "https://www.first.org/tlp/"
      }
    },
    "lang": "en-US",
    "notes": [
      {
        "audience": "all",
        "category": "summary",
        "text": "SICK received a report that informed SICK about an Inadequate Encryption Strength vulnerability in the SICK product \u201cSICK Visionary-S CX\u201d concerning the internal SSH interface solely used by SICK for recovering returned devices.\n\nCurrently SICK is not aware of any public exploits specifically targeting this vulnerability."
      },
      {
        "audience": "all",
        "category": "details",
        "text": "The vulnerability is not visible in any supported customer functionality. Thus customers can only\nidentify products by firmware version. Accessing the device via SSH now shows OpenSSH instead of\ndropbear."
      },
      {
        "category": "general",
        "text": "As general security measures, SICK recommends to minimize network exposure of the devices, restrict network access and follow recommended security practices in order to run the devices in a protected IT environment.",
        "title": "General Security Measures"
      },
      {
        "category": "general",
        "text": "SICK performs vulnerability classification by using the CVSS scoring system (*CVSS v3.1*). The environmental score is dependent on the customer\u2019s environment and can affect the overall CVSS score. SICK recommends that customers individually evaluate the environmental score to achieve final scoring.",
        "title": "Vulnerability Classification"
      }
    ],
    "publisher": {
      "category": "vendor",
      "contact_details": "psirt@sick.de",
      "issuing_authority": "SICK AG issues and issues in EHS products (when related to the Endress+Hauser SICK (EHS) joint venture).",
      "name": "SICK PSIRT",
      "namespace": "https://www.sick.com/psirt"
    },
    "references": [
      {
        "summary": "SICK PSIRT Security Advisories",
        "url": "https://sick.com/psirt"
      },
      {
        "summary": "SICK Operating Guidelines",
        "url": "https://www.sick.com/media/docs/9/19/719/special_information_sick_operating_guidelines_cybersecurity_by_sick_en_im0106719.pdf"
      },
      {
        "summary": "ICS-CERT recommended practices on Industrial Security",
        "url": "http://ics-cert.us-cert.gov/content/recommended-practices"
      },
      {
        "summary": "CVSS v3.1 Calculator",
        "url": "https://www.first.org/cvss/calculator/3.1"
      },
      {
        "summary": "BSI Technical Guideline for the use of the cryptographic protocol Secure Shell (SSH)",
        "url": "https://www.bsi.bund.de/SharedDocs/Downloads/EN/BSI/Publications/TechGuidelines/TG02102/BSI-TR-02102-4.pdf"
      },
      {
        "category": "self",
        "summary": "The canonical URL.",
        "url": "https://www.sick.com/.well-known/csaf/white/2021/sca-2021-0001.json"
      }
    ],
    "title": "Inadequate SSH configuration in SICK Visionary-S CX",
    "tracking": {
      "current_release_date": "2026-11-13T15:18:31.000Z",
      "generator": {
        "date": "2023-02-09T15:17:22.721Z",
        "engine": {
          "name": "Secvisogram",
          "version": "2.0.0"
        }
      },
      "id": "SCA-2021-0001",
      "initial_release_date": "2021-06-26T10:00:00.000Z",
      "revision_history": [
        {
          "date": "2021-06-26T10:00:00.000Z",
          "number": "1",
          "summary": "Initial Release"
        },
        {
          "date": "2023-02-09T11:00:00.000Z",
          "number": "2",
          "summary": "Updated Advisory (only visual changes)"
        },
        {
          "date": "2025-07-30T07:27:50.000Z",
          "number": "3",
          "summary": "Updated Advisory: URL for SICK Operating Guidelines has been updated"
        },
        {
          "date": "2026-11-13T15:18:31.000Z",
          "number": "4",
          "summary": "Corrected initial_release_date to match the date of the initial revision (revision 1). No changes to vulnerability, product, or remediation information."
        }
      ],
      "status": "final",
      "version": "4"
    }
  },
  "product_tree": {
    "branches": [
      {
        "branches": [
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "vers:all/*",
                "product": {
                  "name": "SICK Visionary-S CX all versions",
                  "product_id": "CSAFPID-0001"
                }
              }
            ],
            "category": "product_name",
            "name": "Visionary-S CX"
          },
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "\u003c5.21.2.29154R",
                "product": {
                  "name": "SICK Visionary-S CX Firmware \u003c5.21.2.29154R",
                  "product_id": "CSAFPID-0002"
                }
              },
              {
                "category": "product_version",
                "name": "5.21.2.29154R",
                "product": {
                  "name": "SICK Visionary-S CX Firmware 5.21.2.29154R",
                  "product_id": "CSAFPID-0003"
                }
              }
            ],
            "category": "product_name",
            "name": "Visionary-S CX Firmware"
          }
        ],
        "category": "vendor",
        "name": "SICK AG"
      }
    ],
    "relationships": [
      {
        "category": "installed_on",
        "full_product_name": {
          "name": "SICK Visionary-S CX with Firmware \u003c5.21.2.29154R",
          "product_id": "CSAFPID-0004"
        },
        "product_reference": "CSAFPID-0002",
        "relates_to_product_reference": "CSAFPID-0001"
      },
      {
        "category": "installed_on",
        "full_product_name": {
          "name": "SICK Visionary-S CX with Firmware 5.21.2.29154R",
          "product_id": "CSAFPID-0005"
        },
        "product_reference": "CSAFPID-0003",
        "relates_to_product_reference": "CSAFPID-0001"
      }
    ]
  },
  "vulnerabilities": [
    {
      "cve": "CVE-2021-32496",
      "cwe": {
        "id": "CWE-326",
        "name": "Inadequate Encryption Strength"
      },
      "notes": [
        {
          "category": "description",
          "text": "The use of weak algorithms makes it easier for an attacker to break the security that protects information transmitted from the client to the SSH server, assuming the attacker has access to the network on which the device is connected. This can increase the risk that encryption will be compromised, leading to the exposure of sensitive user information and man-in-the-middle attacks.\nSICK has developed a hotfix. In released firmware versions greater than 5.21.2.29154 the SSH server will no longer offer these weak ciphers."
        }
      ],
      "product_status": {
        "fixed": [
          "CSAFPID-0005"
        ],
        "known_affected": [
          "CSAFPID-0004"
        ]
      },
      "remediations": [
        {
          "category": "vendor_fix",
          "details": "Update to version 5.21.2.29154R or higher",
          "product_ids": [
            "CSAFPID-0004"
          ]
        }
      ],
      "scores": [
        {
          "cvss_v3": {
            "attackComplexity": "HIGH",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 3.7,
            "baseSeverity": "LOW",
            "confidentialityImpact": "LOW",
            "integrityImpact": "LOW",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:N/AC:H/PR:L/UI:R/S:U/C:L/I:L/A:N",
            "version": "3.1"
          },
          "products": [
            "CSAFPID-0004"
          ]
        }
      ]
    }
  ]
}



Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Drag nodes to arrange them. Double-click a related vulnerability to open it, or a source to visit its link. The Physics button on the left tunes the layout and the simulation; the legend at the bottom left hides or shows nodes by kind and by sighting type.

Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.

Sightings

Author Source Type Date Other

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Vulnerability timeline

Sightings and recorded dates, grouped by day · UTC

JSON
How durations are calculated

Following the VTEM framework (Black Hat USA 2015), time to patch starts when the vendor or a coordinator was informed, total time to patch at discovery, and disclosure to patch at public disclosure; vendor response time runs from the report to its acknowledgement. Time to exploit and time unpatched start at the earliest discovery or report, falling back to public disclosure. Unpatched time ends at the first recorded patch, or the calculation time when no patch is recorded. Exploitation to patch shows the interval between those two events; a published proof of concept is a public exploit, not exploitation. The method is described in a publication.

Each result shows its source dates. A negative interval means the end event came first; when date-only inputs leave the order open, the result says so. Date-only inputs are approximate. The earliest evidence wins: KEV report dates and sightings are labelled as such. Records describing another vulnerability are listed but never calculated from, and a PoC alone does not establish exploitation. Missing patch evidence does not prove that no patch exists. Filters below change the event list only.

Events included in the timeline

Loading timeline…


    Loading…

    Loading…

    Loading…

    Related by attack behaviour

    Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.