ICSMA-22-263-01
Vulnerability from csaf_cisa - Published: 2022-09-20 00:00 - Updated: 2022-09-20 00:00| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
MiniMed 620G: MMT-1710
Medtronic / MiniMed 620G
|
MMT-1710 |
Vendor Fix
Vendor Fix
Vendor Fix
|
|
|
MiniMed 630G: MMT-1715 MMT-1754 MMT-1755
Medtronic / MiniMed 630G
|
MMT-1715 | MMT-1754 | MMT-1755 |
Vendor Fix
Vendor Fix
Vendor Fix
|
|
|
MiniMed 640G: MMT-1711 MMT-1712 MMT-1751 MMT-1752
Medtronic / MiniMed 640G
|
MMT-1711 | MMT-1712 | MMT-1751 | MMT-1752 |
Vendor Fix
Vendor Fix
Vendor Fix
|
|
|
MiniMed 670G: MMT-1740 MMT-1741 MMT-1742 MMT-1760 MMT-1762 MMT-1762 MMT-1780 MMT-1781 MMT-1782
Medtronic / MiniMed 670G
|
MMT-1740 | MMT-1741 | MMT-1742 | MMT-1760 | MMT-1762 | MMT-1762 | MMT-1780 | MMT-1781 | MMT-1782 |
Vendor Fix
Vendor Fix
Vendor Fix
|
{
"document": {
"acknowledgments": [
{
"organization": "Medtronic",
"summary": "identifying and reporting this vulnerability to CISA"
}
],
"category": "csaf_security_advisory",
"csaf_version": "2.0",
"distribution": {
"text": "Disclosure is not limited",
"tlp": {
"label": "WHITE",
"url": "https://us-cert.cisa.gov/tlp/"
}
},
"lang": "en-US",
"notes": [
{
"category": "general",
"text": "This CSAF advisory was extracted from unstructured data and may contain inaccuracies. If you notice any errors, please reach out to the designated contact at CISA CSAF: central@cisa.dhs.gov",
"title": "CISA Disclaimer"
},
{
"category": "legal_disclaimer",
"text": "All information products included in https://us-cert.cisa.gov/ics are provided \"as is\" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.",
"title": "Legal Notice"
},
{
"category": "summary",
"text": "Successful exploitation of this vulnerability could allow an unauthorized user to deliver too much or too little insulin through delivery of an unintended insulin bolus or because insulin delivery is slowed or stopped.",
"title": "Risk evaluation"
},
{
"category": "other",
"text": "Healthcare and Public Health",
"title": "Critical infrastructure sectors"
},
{
"category": "other",
"text": "Worldwide",
"title": "Countries/areas deployed"
},
{
"category": "other",
"text": "Ireland",
"title": "Company headquarters location"
},
{
"category": "general",
"text": "CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "CISA also provides a section for control systems security recommended practices on the ICS webpage at cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.",
"title": "Recommended Practices"
},
{
"category": "other",
"text": "No known public exploits specifically target this vulnerability. This vulnerability has a high attack complexity.",
"title": "Exploitability"
}
],
"publisher": {
"category": "coordinator",
"contact_details": "Email: CISAservicedesk@cisa.dhs.gov;\n Toll Free: 1-888-282-0870",
"name": "CISA",
"namespace": "https://www.cisa.gov/"
},
"references": [
{
"category": "self",
"summary": "ICS Advisory ICSMA-22-263-01 JSON",
"url": "https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2022/icsma-22-263-01.json"
},
{
"category": "self",
"summary": "ICS Advisory ICSMA-22-263-01 Web Version",
"url": "https://www.cisa.gov/news-events/ics-medical-advisories/icsma-22-263-01"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/news-events/ics-medical-advisories/icsma-22-263-01"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://us-cert.cisa.gov/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf"
}
],
"title": "Medtronic NGP 600 Series Insulin Pumps",
"tracking": {
"current_release_date": "2022-09-20T00:00:00.000000Z",
"generator": {
"engine": {
"name": "CISA CSAF Generator",
"version": "1.0.0"
}
},
"id": "ICSMA-22-263-01",
"initial_release_date": "2022-09-20T00:00:00.000000Z",
"revision_history": [
{
"date": "2022-09-20T00:00:00.000000Z",
"legacy_version": "Initial",
"number": "1",
"summary": "Publication Date"
}
],
"status": "final",
"version": "1"
}
},
"product_tree": {
"branches": [
{
"branches": [
{
"branches": [
{
"category": "product_version",
"name": "MMT-1710",
"product": {
"name": "MiniMed 620G: MMT-1710",
"product_id": "CSAFPID-0001"
}
}
],
"category": "product_name",
"name": "MiniMed 620G"
},
{
"branches": [
{
"category": "product_version",
"name": "MMT-1715 | MMT-1754 | MMT-1755",
"product": {
"name": "MiniMed 630G: MMT-1715 MMT-1754 MMT-1755",
"product_id": "CSAFPID-0002"
}
}
],
"category": "product_name",
"name": "MiniMed 630G"
},
{
"branches": [
{
"category": "product_version",
"name": "MMT-1711 | MMT-1712 | MMT-1751 | MMT-1752",
"product": {
"name": "MiniMed 640G: MMT-1711 MMT-1712 MMT-1751 MMT-1752",
"product_id": "CSAFPID-0003"
}
}
],
"category": "product_name",
"name": "MiniMed 640G"
},
{
"branches": [
{
"category": "product_version",
"name": "MMT-1740 | MMT-1741 | MMT-1742 | MMT-1760 | MMT-1762 | MMT-1762 | MMT-1780 | MMT-1781 | MMT-1782",
"product": {
"name": "MiniMed 670G: MMT-1740 MMT-1741 MMT-1742 MMT-1760 MMT-1762 MMT-1762 MMT-1780 MMT-1781 MMT-1782",
"product_id": "CSAFPID-0004"
}
}
],
"category": "product_name",
"name": "MiniMed 670G"
}
],
"category": "vendor",
"name": "Medtronic"
}
]
},
"vulnerabilities": [
{
"cve": "CVE-2022-32537",
"cwe": {
"id": "CWE-693",
"name": "Protection Mechanism Failure"
},
"notes": [
{
"category": "summary",
"text": "A vulnerability exists which could allow an unauthorized user to learn aspects of the communication protocol used to pair system components while the pump is being paired with other system components. Exploitation requires nearby wireless signal proximity with the patient and the device; advanced technical knowledge is required for exploitation.CVE-2022-32537 has been assigned to this vulnerability. A CVSS v3 base score of 4.8 has been calculated; the CVSS vector string is (AV:A/AC:H/PR:L/UI:N/S:U/C:N/I:H/A:N).",
"title": "Vulnerability Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004"
]
},
"references": [
{
"category": "external",
"summary": "web.nvd.nist.gov",
"url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2022-32537"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:A/AC:H/PR:L/UI:N/S:U/C:N/I:H/A:N"
}
],
"remediations": [
{
"category": "vendor_fix",
"details": "Medtronic recommends users to take the following actions:",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004"
]
},
{
"category": "vendor_fix",
"details": "Note: Turning off the remote bolus feature will ensure no remote bolus is possible.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004"
]
},
{
"category": "vendor_fix",
"details": "Medtronic has identified the following precautions to assist users:",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 4.8,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.0/AV:A/AC:H/PR:L/UI:N/S:U/C:N/I:H/A:N",
"version": "3.0"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004"
]
}
]
}
]
}
Drag nodes to arrange them. Double-click a related vulnerability to open it, or a source to visit its link. The Physics button on the left tunes the layout and the simulation; the legend at the bottom left hides or shows nodes by kind and by sighting type.
Sightings
| Author | Source | Type | Date | Other |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Vulnerability timeline
Sightings and recorded dates, grouped by day · UTC
How durations are calculated
Following the VTEM framework (Black Hat USA 2015), time to patch starts when the vendor or a coordinator was informed, total time to patch at discovery, and disclosure to patch at public disclosure; vendor response time runs from the report to its acknowledgement. Time to exploit and time unpatched start at the earliest discovery or report, falling back to public disclosure. Unpatched time ends at the first recorded patch, or the calculation time when no patch is recorded. Exploitation to patch shows the interval between those two events; a published proof of concept is a public exploit, not exploitation.
Each result shows its source dates. A negative interval means the end event came first; when date-only inputs leave the order open, the result says so. Date-only inputs are approximate. The earliest evidence wins: KEV report dates and sightings are labelled as such. Records describing another vulnerability are listed but never calculated from, and a PoC alone does not establish exploitation. Missing patch evidence does not prove that no patch exists. Filters below change the event list only.
Loading timeline…
The approach is described in our paper Mapping CVEs to MITRE ATT&CK Techniques: A Curated Gold-Set Classifier and the Limits of LLM-Assisted Label Expansion.
Browse all ATT&CK techniques and the vulnerabilities related to each.
Related by attack behaviour
Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.