ICSA-25-317-12
Vulnerability from csaf_cisa - Published: 2025-11-13 07:00 - Updated: 2025-11-13 07:00{
"document": {
"acknowledgments": [
{
"names": [
"Felix Eberstaller",
"Sixtus Leonhardsberger"
],
"organization": "Limes Security",
"summary": "reporting these vulnerabilities to Siemens"
}
],
"category": "csaf_security_advisory",
"csaf_version": "2.0",
"distribution": {
"text": "Disclosure is not limited",
"tlp": {
"label": "WHITE",
"url": "https://www.cisa.gov/news-events/news/traffic-light-protocol-tlp-definitions-and-usage"
}
},
"lang": "en-US",
"notes": [
{
"category": "legal_disclaimer",
"text": "This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy \u0026 Use policy (https://www.cisa.gov/privacy-policy).",
"title": "Legal Notice and Terms of Use"
},
{
"category": "summary",
"text": "Successful exploitation of these vulnerabilities could allow an attacker to remotely execute code as application administrator or locally execute code as operating system administrator.",
"title": "Risk evaluation"
},
{
"category": "other",
"text": "Energy",
"title": "Critical infrastructure sectors"
},
{
"category": "other",
"text": "Worldwide",
"title": "Countries/areas deployed"
},
{
"category": "other",
"text": "Germany",
"title": "Company headquarters location"
},
{
"category": "general",
"text": "CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities, such as:",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "Locate control system networks and remote devices behind firewalls and isolating them from business networks.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs). Recognize VPNs may have vulnerabilities, should be updated to the most recent version available, and are only as secure as the connected devices.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "CISA also recommends users take the following measures to protect themselves from social engineering attacks:",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "Do not click web links or open attachments in unsolicited email messages.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "Refer to Recognizing and Avoiding Email Scams for more information on avoiding email scams.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "Refer to Avoiding Social Engineering and Phishing Attacks for more information on social engineering attacks.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "No known public exploitation specifically targeting these vulnerabilities has been reported to CISA at this time.",
"title": "Recommended Practices"
}
],
"publisher": {
"category": "coordinator",
"contact_details": "central@cisa.dhs.gov",
"name": "CISA",
"namespace": "https://www.cisa.gov/"
},
"references": [
{
"category": "self",
"summary": "ICS Advisory ICSA-25-317-12 JSON",
"url": "https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2025/icsa-25-317-12.json"
},
{
"category": "self",
"summary": "ICSA Advisory ICSA-25-317-12 - Web Version",
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-25-317-12"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/uscert/ics/alerts/ICS-ALERT-10-301-01"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/resources-tools/resources/ics-recommended-practices"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/sites/default/files/publications/Cybersecurity_Best_Practices_for_Industrial_Control_Systems.pdf"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/topics/industrial-control-systems"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/uscert/sites/default/files/publications/emailscams0905.pdf"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/uscert/ncas/tips/ST04-014"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/news-events/ics-alerts/ics-alert-10-301-01"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/news-events/news/targeted-cyber-intrusion-detection-and-mitigation-strategies-update-b"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/secure-our-world/teach-employees-avoid-phishing"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/news-events/news/avoiding-social-engineering-and-phishing-attacks"
}
],
"title": "Siemens Spectrum Power 4",
"tracking": {
"current_release_date": "2025-11-13T07:00:00.000000Z",
"generator": {
"date": "2025-11-13T16:43:41.186998Z",
"engine": {
"name": "CISA CSAF Generator",
"version": "1.0.0"
}
},
"id": "ICSA-25-317-12",
"initial_release_date": "2025-11-13T07:00:00.000000Z",
"revision_history": [
{
"date": "2025-11-13T07:00:00.000000Z",
"legacy_version": "Initial",
"number": "1",
"summary": "Initial Publication"
}
],
"status": "final",
"version": "1"
}
},
"product_tree": {
"branches": [
{
"branches": [
{
"branches": [
{
"category": "product_version_range",
"name": "\u003cV4.70_SP12_Update_2",
"product": {
"name": "Siemens Spectrum Power 4: \u003cV4.70_SP12_Update_2",
"product_id": "CSAFPID-0001"
}
}
],
"category": "product_name",
"name": "Spectrum Power 4"
}
],
"category": "vendor",
"name": "Siemens"
}
]
},
"vulnerabilities": [
{
"cve": "CVE-2024-32008",
"cwe": {
"id": "CWE-648",
"name": "Incorrect Use of Privileged APIs"
},
"notes": [
{
"category": "summary",
"text": "The affected application is vulnerable to a local privilege escalation due to an exposed debug interface on the localhost. This allows any local user to gain code execution as administrative application user.",
"title": "Vulnerability Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001"
]
},
"references": [
{
"category": "external",
"summary": "www.cve.org",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-32008"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/4.0#CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N"
}
],
"remediations": [
{
"category": "mitigation",
"details": "Siemens has identified the following specific workarounds and mitigations users can apply to reduce risk:",
"product_ids": [
"CSAFPID-0001"
]
},
{
"category": "vendor_fix",
"details": "Spectrum Power 4: Update to V4.70 SP12 Update 2 or later version",
"product_ids": [
"CSAFPID-0001"
]
},
{
"category": "mitigation",
"details": "As a general security measure, Siemens recommends protecting network access to devices with appropriate mechanisms. To operate the devices in a protected IT environment, Siemens recommends configuring the environment according to Siemens\u0027 operational guidelines for industrial security and following recommendations in the product manuals.",
"product_ids": [
"CSAFPID-0001"
],
"url": "https://www.siemens.com/cert/operational-guidelines-industrial-security"
},
{
"category": "mitigation",
"details": "Additional information on industrial security by Siemens can be found on the Siemens industrial security webpage",
"product_ids": [
"CSAFPID-0001"
],
"url": "https://www.siemens.com/industrialsecurity"
},
{
"category": "mitigation",
"details": "For more information see the associated Siemens security advisory SSA-339694 in HTML and CSAF.",
"product_ids": [
"CSAFPID-0001"
],
"url": "https://cert-portal.siemens.com/productcert/html/ssa-339694.html"
},
{
"category": "mitigation",
"details": "For more information see the associated Siemens security advisory SSA-339694 in HTML and CSAF.",
"product_ids": [
"CSAFPID-0001"
],
"url": "https://cert-portal.siemens.com/productcert/csaf/ssa-339694.json"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"products": [
"CSAFPID-0001"
]
}
]
},
{
"cve": "CVE-2024-32009",
"cwe": {
"id": "CWE-266",
"name": "Incorrect Privilege Assignment"
},
"notes": [
{
"category": "summary",
"text": "The affected application is vulnerable to a local privilege escalation due to wrongly set permissions to a binary which allows any local attacker to gain administrative privileges.",
"title": "Vulnerability Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001"
]
},
"references": [
{
"category": "external",
"summary": "www.cve.org",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-32009"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/4.0#CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N"
}
],
"remediations": [
{
"category": "mitigation",
"details": "Siemens has identified the following specific workarounds and mitigations users can apply to reduce risk:",
"product_ids": [
"CSAFPID-0001"
]
},
{
"category": "vendor_fix",
"details": "Spectrum Power 4: Update to V4.70 SP12 Update 2 or later version",
"product_ids": [
"CSAFPID-0001"
]
},
{
"category": "mitigation",
"details": "As a general security measure, Siemens recommends protecting network access to devices with appropriate mechanisms. To operate the devices in a protected IT environment, Siemens recommends configuring the environment according to Siemens\u0027 operational guidelines for industrial security and following recommendations in the product manuals.",
"product_ids": [
"CSAFPID-0001"
],
"url": "https://www.siemens.com/cert/operational-guidelines-industrial-security"
},
{
"category": "mitigation",
"details": "Additional information on industrial security by Siemens can be found on the Siemens industrial security webpage",
"product_ids": [
"CSAFPID-0001"
],
"url": "https://www.siemens.com/industrialsecurity"
},
{
"category": "mitigation",
"details": "For more information see the associated Siemens security advisory SSA-339694 in HTML and CSAF.",
"product_ids": [
"CSAFPID-0001"
],
"url": "https://cert-portal.siemens.com/productcert/html/ssa-339694.html"
},
{
"category": "mitigation",
"details": "For more information see the associated Siemens security advisory SSA-339694 in HTML and CSAF.",
"product_ids": [
"CSAFPID-0001"
],
"url": "https://cert-portal.siemens.com/productcert/csaf/ssa-339694.json"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"products": [
"CSAFPID-0001"
]
}
]
},
{
"cve": "CVE-2024-32010",
"cwe": {
"id": "CWE-732",
"name": "Incorrect Permission Assignment for Critical Resource"
},
"notes": [
{
"category": "summary",
"text": "The affected application is vulnerable to extraction of database credentials via a world-readable credential file. This allows an attacker to connect to the database as privileged application user and to run system commands via the database.",
"title": "Vulnerability Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001"
]
},
"references": [
{
"category": "external",
"summary": "www.cve.org",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-32010"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/4.0#CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N"
}
],
"remediations": [
{
"category": "mitigation",
"details": "Siemens has identified the following specific workarounds and mitigations users can apply to reduce risk:",
"product_ids": [
"CSAFPID-0001"
]
},
{
"category": "vendor_fix",
"details": "Spectrum Power 4: Update to V4.70 SP12 Update 2 or later version",
"product_ids": [
"CSAFPID-0001"
]
},
{
"category": "mitigation",
"details": "As a general security measure, Siemens recommends protecting network access to devices with appropriate mechanisms. To operate the devices in a protected IT environment, Siemens recommends configuring the environment according to Siemens\u0027 operational guidelines for industrial security and following recommendations in the product manuals.",
"product_ids": [
"CSAFPID-0001"
],
"url": "https://www.siemens.com/cert/operational-guidelines-industrial-security"
},
{
"category": "mitigation",
"details": "Additional information on industrial security by Siemens can be found on the Siemens industrial security webpage",
"product_ids": [
"CSAFPID-0001"
],
"url": "https://www.siemens.com/industrialsecurity"
},
{
"category": "mitigation",
"details": "For more information see the associated Siemens security advisory SSA-339694 in HTML and CSAF.",
"product_ids": [
"CSAFPID-0001"
],
"url": "https://cert-portal.siemens.com/productcert/html/ssa-339694.html"
},
{
"category": "mitigation",
"details": "For more information see the associated Siemens security advisory SSA-339694 in HTML and CSAF.",
"product_ids": [
"CSAFPID-0001"
],
"url": "https://cert-portal.siemens.com/productcert/csaf/ssa-339694.json"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"products": [
"CSAFPID-0001"
]
}
]
},
{
"cve": "CVE-2024-32011",
"cwe": {
"id": "CWE-829",
"name": "Inclusion of Functionality from Untrusted Control Sphere"
},
"notes": [
{
"category": "summary",
"text": "The affected application is vulnerable to run arbitrary commands via the user interface. This user interface can be used via the network and allows the execution of commands as administrative application user.",
"title": "Vulnerability Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001"
]
},
"references": [
{
"category": "external",
"summary": "www.cve.org",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-32011"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/4.0#CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N"
}
],
"remediations": [
{
"category": "mitigation",
"details": "Siemens has identified the following specific workarounds and mitigations users can apply to reduce risk:",
"product_ids": [
"CSAFPID-0001"
]
},
{
"category": "vendor_fix",
"details": "Spectrum Power 4: Update to V4.70 SP12 Update 2 or later version",
"product_ids": [
"CSAFPID-0001"
]
},
{
"category": "mitigation",
"details": "As a general security measure, Siemens recommends protecting network access to devices with appropriate mechanisms. To operate the devices in a protected IT environment, Siemens recommends configuring the environment according to Siemens\u0027 operational guidelines for industrial security and following recommendations in the product manuals.",
"product_ids": [
"CSAFPID-0001"
],
"url": "https://www.siemens.com/cert/operational-guidelines-industrial-security"
},
{
"category": "mitigation",
"details": "Additional information on industrial security by Siemens can be found on the Siemens industrial security webpage",
"product_ids": [
"CSAFPID-0001"
],
"url": "https://www.siemens.com/industrialsecurity"
},
{
"category": "mitigation",
"details": "For more information see the associated Siemens security advisory SSA-339694 in HTML and CSAF.",
"product_ids": [
"CSAFPID-0001"
],
"url": "https://cert-portal.siemens.com/productcert/html/ssa-339694.html"
},
{
"category": "mitigation",
"details": "For more information see the associated Siemens security advisory SSA-339694 in HTML and CSAF.",
"product_ids": [
"CSAFPID-0001"
],
"url": "https://cert-portal.siemens.com/productcert/csaf/ssa-339694.json"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"products": [
"CSAFPID-0001"
]
}
]
},
{
"cve": "CVE-2024-32014",
"cwe": {
"id": "CWE-732",
"name": "Incorrect Permission Assignment for Critical Resource"
},
"notes": [
{
"category": "summary",
"text": "The affected application is vulnerable to alter the local database which contains the application credentials. This allows an attacker to gain administrative application privileges.",
"title": "Vulnerability Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001"
]
},
"references": [
{
"category": "external",
"summary": "www.cve.org",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-32014"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:L/AC:H/PR:N/UI:R/S:U/C:H/I:N/A:N"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/4.0#CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:A/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N"
}
],
"remediations": [
{
"category": "mitigation",
"details": "Siemens has identified the following specific workarounds and mitigations users can apply to reduce risk:",
"product_ids": [
"CSAFPID-0001"
]
},
{
"category": "vendor_fix",
"details": "Spectrum Power 4: Update to V4.70 SP12 Update 2 or later version",
"product_ids": [
"CSAFPID-0001"
]
},
{
"category": "mitigation",
"details": "As a general security measure, Siemens recommends protecting network access to devices with appropriate mechanisms. To operate the devices in a protected IT environment, Siemens recommends configuring the environment according to Siemens\u0027 operational guidelines for industrial security and following recommendations in the product manuals.",
"product_ids": [
"CSAFPID-0001"
],
"url": "https://www.siemens.com/cert/operational-guidelines-industrial-security"
},
{
"category": "mitigation",
"details": "Additional information on industrial security by Siemens can be found on the Siemens industrial security webpage",
"product_ids": [
"CSAFPID-0001"
],
"url": "https://www.siemens.com/industrialsecurity"
},
{
"category": "mitigation",
"details": "For more information see the associated Siemens security advisory SSA-339694 in HTML and CSAF.",
"product_ids": [
"CSAFPID-0001"
],
"url": "https://cert-portal.siemens.com/productcert/html/ssa-339694.html"
},
{
"category": "mitigation",
"details": "For more information see the associated Siemens security advisory SSA-339694 in HTML and CSAF.",
"product_ids": [
"CSAFPID-0001"
],
"url": "https://cert-portal.siemens.com/productcert/csaf/ssa-339694.json"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 4.7,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:L/AC:H/PR:N/UI:R/S:U/C:H/I:N/A:N",
"version": "3.1"
},
"products": [
"CSAFPID-0001"
]
}
]
}
]
}
Drag nodes to arrange them. Double-click a related vulnerability to open it, or a source to visit its link. The Physics button on the left tunes the layout and the simulation; the legend at the bottom left hides or shows nodes by kind and by sighting type.
Sightings
| Author | Source | Type | Date | Other |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Vulnerability timeline
Sightings and recorded dates, grouped by day · UTC
How durations are calculated
Following the VTEM framework (Black Hat USA 2015), time to patch starts when the vendor or a coordinator was informed, total time to patch at discovery, and disclosure to patch at public disclosure; vendor response time runs from the report to its acknowledgement. Time to exploit and time unpatched start at the earliest discovery or report, falling back to public disclosure. Unpatched time ends at the first recorded patch, or the calculation time when no patch is recorded. Exploitation to patch shows the interval between those two events; a published proof of concept is a public exploit, not exploitation.
Each result shows its source dates. A negative interval means the end event came first; when date-only inputs leave the order open, the result says so. Date-only inputs are approximate. The earliest evidence wins: KEV report dates and sightings are labelled as such. Records describing another vulnerability are listed but never calculated from, and a PoC alone does not establish exploitation. Missing patch evidence does not prove that no patch exists. Filters below change the event list only.
Loading timeline…
The approach is described in our paper Mapping CVEs to MITRE ATT&CK Techniques: A Curated Gold-Set Classifier and the Limits of LLM-Assisted Label Expansion.
Browse all ATT&CK techniques and the vulnerabilities related to each.
Related by attack behaviour
Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.