ICSA-25-044-07
Vulnerability from csaf_cisa - Published: 2025-02-11 00:00 - Updated: 2025-06-10 00:00| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
Teamcenter V14.1
Siemens / Teamcenter V14.1
|
vers:all/* |
Mitigation
Vendor Fix
|
|
|
Teamcenter V14.2
Siemens / Teamcenter V14.2
|
vers:all/* |
Mitigation
Vendor Fix
|
|
|
Teamcenter V14.3
Siemens / Teamcenter V14.3
|
vers:all/<V14.3.0.14 |
Mitigation
Vendor Fix
fix
|
|
|
Teamcenter V2312
Siemens / Teamcenter V2312
|
vers:all/<V2312.0010 |
Mitigation
Vendor Fix
fix
|
|
|
Teamcenter V2406
Siemens / Teamcenter V2406
|
vers:all/<V2406.0008 |
Mitigation
Vendor Fix
fix
|
|
|
Teamcenter V2412
Siemens / Teamcenter V2412
|
vers:all/<V2412.0004 |
Mitigation
Vendor Fix
fix
|
{
"document": {
"acknowledgments": [
{
"organization": "Siemens ProductCERT",
"summary": "reporting this vulnerability to CISA."
},
{
"names": [
"Nicolo Vinci"
],
"summary": "reporting this vulnerability to Siemens."
}
],
"category": "csaf_security_advisory",
"csaf_version": "2.0",
"distribution": {
"text": "Disclosure is not limited",
"tlp": {
"label": "WHITE",
"url": "https://us-cert.cisa.gov/tlp/"
}
},
"lang": "en",
"notes": [
{
"category": "summary",
"text": "The SSO login service in Teamcenter contains an open redirect vulnerability that could allow an attacker to redirect the legitimate user to an attacker-chosen URL to steal valid session data.\n\nSiemens has released new versions for the affected products and recommends to update to the latest versions.",
"title": "Summary"
},
{
"category": "general",
"text": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity",
"title": "General Recommendations"
},
{
"category": "general",
"text": "For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories",
"title": "Additional Resources"
},
{
"category": "legal_disclaimer",
"text": "The use of Siemens Security Advisories is subject to the terms and conditions listed on: https://www.siemens.com/productcert/terms-of-use.",
"title": "Terms of Use"
},
{
"category": "legal_disclaimer",
"text": "All information products included in https://us-cert.cisa.gov/ics are provided \"as is\" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.",
"title": "Legal Notice"
},
{
"category": "other",
"text": "This ICSA is a verbatim republication of Siemens ProductCERT SSA-656895 from a direct conversion of their vendor\u0027s Common Security Advisory Framework (CSAF) advisory. This is republished to CISA\u0027s website as a means of increasing visibility and is provided \"as-is\" for informational purposes only. CISA is not responsible for the editorial or technical accuracy of republished advisories and provides no warranties of any kind regarding any information contained within this advisory. Further, CISA does not endorse any commercial product or service. Please contact Siemens ProductCERT directly for any questions regarding this advisory.",
"title": "Advisory Conversion Disclaimer"
},
{
"category": "other",
"text": "Critical Manufacturing",
"title": "Critical infrastructure sectors"
},
{
"category": "other",
"text": "Worldwide",
"title": "Countries/areas deployed"
},
{
"category": "other",
"text": "Germany",
"title": "Company headquarters location"
},
{
"category": "general",
"text": "CISA recommends users take defensive measures to minimize the exploitation risk of these vulnerabilities.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "Locate control system networks and remote devices behind firewalls and isolate them from business networks.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.",
"title": "Recommended Practices"
}
],
"publisher": {
"category": "other",
"contact_details": "central@cisa.dhs.gov",
"name": "CISA",
"namespace": "https://www.cisa.gov/"
},
"references": [
{
"category": "self",
"summary": "SSA-656895: Open Redirect Vulnerability in Teamcenter - CSAF Version",
"url": "https://cert-portal.siemens.com/productcert/csaf/ssa-656895.json"
},
{
"category": "self",
"summary": "SSA-656895: Open Redirect Vulnerability in Teamcenter - HTML Version",
"url": "https://cert-portal.siemens.com/productcert/html/ssa-656895.html"
},
{
"category": "self",
"summary": "ICS Advisory ICSA-25-044-07 JSON",
"url": "https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2025/icsa-25-044-07.json"
},
{
"category": "self",
"summary": "ICS Advisory ICSA-25-044-07 - Web Version",
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-25-044-07"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/uscert/ics/alerts/ICS-ALERT-10-301-01"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/resources-tools/resources/ics-recommended-practices"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/topics/industrial-control-systems"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://us-cert.cisa.gov/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/sites/default/files/publications/Cybersecurity_Best_Practices_for_Industrial_Control_Systems.pdf"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/uscert/ics/tips/ICS-TIP-12-146-01B"
}
],
"title": "Siemens Teamcenter",
"tracking": {
"current_release_date": "2025-06-10T00:00:00.000000Z",
"generator": {
"date": "2025-06-12T16:06:24.160248Z",
"engine": {
"name": "CISA CSAF Generator",
"version": "1.0.0"
}
},
"id": "ICSA-25-044-07",
"initial_release_date": "2025-02-11T00:00:00.000000Z",
"revision_history": [
{
"date": "2025-02-11T00:00:00.000000Z",
"legacy_version": "1.0",
"number": "1",
"summary": "Publication Date"
},
{
"date": "2025-02-25T00:00:00.000000Z",
"legacy_version": "1.1",
"number": "2",
"summary": "Removed fix version information as the implemented fix was insufficient - final fix being worked on for future release(s)"
},
{
"date": "2025-03-20T00:00:00.000000Z",
"legacy_version": "1.2",
"number": "3",
"summary": "Added hot fixes for Teamcenter V14.1 through V2412"
},
{
"date": "2025-06-10T00:00:00.000000Z",
"legacy_version": "1.3",
"number": "4",
"summary": "Added fix releases for Teamcenter V14.3 through V2412"
}
],
"status": "final",
"version": "4"
}
},
"product_tree": {
"branches": [
{
"branches": [
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "Teamcenter V14.1",
"product_id": "CSAFPID-0001"
}
}
],
"category": "product_name",
"name": "Teamcenter V14.1"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "Teamcenter V14.2",
"product_id": "CSAFPID-0002"
}
}
],
"category": "product_name",
"name": "Teamcenter V14.2"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/\u003cV14.3.0.14",
"product": {
"name": "Teamcenter V14.3",
"product_id": "CSAFPID-0003"
}
}
],
"category": "product_name",
"name": "Teamcenter V14.3"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/\u003cV2312.0010",
"product": {
"name": "Teamcenter V2312",
"product_id": "CSAFPID-0004"
}
}
],
"category": "product_name",
"name": "Teamcenter V2312"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/\u003cV2406.0008",
"product": {
"name": "Teamcenter V2406",
"product_id": "CSAFPID-0005"
}
}
],
"category": "product_name",
"name": "Teamcenter V2406"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/\u003cV2412.0004",
"product": {
"name": "Teamcenter V2412",
"product_id": "CSAFPID-0006"
}
}
],
"category": "product_name",
"name": "Teamcenter V2412"
}
],
"category": "vendor",
"name": "Siemens"
}
]
},
"vulnerabilities": [
{
"cve": "CVE-2025-23363",
"cwe": {
"id": "CWE-601",
"name": "URL Redirection to Untrusted Site (\u0027Open Redirect\u0027)"
},
"notes": [
{
"category": "summary",
"text": "The SSO login service of affected applications accepts user-controlled input that could specify a link to an external site. This could allow an attacker to redirect the legitimate user to an attacker-chosen URL to steal valid session data. For a successful exploit, the legitimate user must actively click on an attacker-crafted link.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Do not click on links from untrusted sources",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006"
]
},
{
"category": "vendor_fix",
"details": "Update to V14.3.0.14 or later version",
"product_ids": [
"CSAFPID-0003"
],
"url": "https://support.sw.siemens.com/product/282219420/"
},
{
"category": "vendor_fix",
"details": "Update to V2312.0010 or later version",
"product_ids": [
"CSAFPID-0004"
],
"url": "https://support.sw.siemens.com/product/282219420/"
},
{
"category": "vendor_fix",
"details": "Update to V2406.0008 or later version",
"product_ids": [
"CSAFPID-0005"
],
"url": "https://support.sw.siemens.com/product/282219420/"
},
{
"category": "vendor_fix",
"details": "Update to V2412.0004 or later version",
"product_ids": [
"CSAFPID-0006"
],
"url": "https://support.sw.siemens.com/product/282219420/"
},
{
"category": "vendor_fix",
"details": "Apply the hot fix as described in Software Field Bulletin PL8837639 (\nhttps://support.sw.siemens.com/en-US/product/282219420/knowledge-base/PL8837639)",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.4,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:H/I:N/A:N",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006"
]
}
],
"title": "CVE-2025-23363"
}
]
}
Drag nodes to arrange them. Double-click a related vulnerability to open it, or a source to visit its link. The Physics button on the left tunes the layout and the simulation; the legend at the bottom left hides or shows nodes by kind and by sighting type.
Sightings
| Author | Source | Type | Date | Other |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Vulnerability timeline
Sightings and recorded dates, grouped by day · UTC
How durations are calculated
Following the VTEM framework (Black Hat USA 2015), time to patch starts when the vendor or a coordinator was informed, total time to patch at discovery, and disclosure to patch at public disclosure; vendor response time runs from the report to its acknowledgement. Time to exploit and time unpatched start at the earliest discovery or report, falling back to public disclosure. Unpatched time ends at the first recorded patch, or the calculation time when no patch is recorded. Exploitation to patch shows the interval between those two events; a published proof of concept is a public exploit, not exploitation.
Each result shows its source dates. A negative interval means the end event came first; when date-only inputs leave the order open, the result says so. Date-only inputs are approximate. The earliest evidence wins: KEV report dates and sightings are labelled as such. Records describing another vulnerability are listed but never calculated from, and a PoC alone does not establish exploitation. Missing patch evidence does not prove that no patch exists. Filters below change the event list only.
Loading timeline…
The approach is described in our paper Mapping CVEs to MITRE ATT&CK Techniques: A Curated Gold-Set Classifier and the Limits of LLM-Assisted Label Expansion.
Browse all ATT&CK techniques and the vulnerabilities related to each.
Related by attack behaviour
Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.