ICSA-19-225-03

Vulnerability from csaf_cisa - Published: 2019-08-13 00:00 - Updated: 2022-02-10 00:00
Summary
ICSA-19-225-03_Siemens SCALANCE X Switches (Update D)
Notes
CISA Disclaimer: This CSAF advisory was extracted from unstructured data and may contain inaccuracies. If you notice any errors, please reach out to the designated contact at CISA CSAF: central@cisa.dhs.gov
Summary: Younes Dragoni and Alessandro Di Pinto from Nozomi Networks and Artem Zinenko from Kaspersky reported these vulnerability details to Siemens.
Exploitability: No known public exploits specifically target this vulnerability.
CWE-410 - Insufficient Resource Pool
Affected products
Product Identifier Version Remediation
SCALANCE X-200RNA: All versions
Siemens / SCALANCE X-200RNA
vers:all/*
Mitigation fix

{
  "document": {
    "acknowledgments": [
      {
        "names": [
          "Younes Dragoni",
          "Alessandro Di Pinto"
        ],
        "organization": "Nozomi Networks",
        "summary": "reporting these vulnerability details to Siemens"
      },
      {
        "names": [
          "Artem Zinenko"
        ],
        "organization": "Kaspersky",
        "summary": "reporting these vulnerability details to Siemens"
      }
    ],
    "category": "csaf_security_advisory",
    "csaf_version": "2.0",
    "distribution": {
      "text": "Disclosure is not limited",
      "tlp": {
        "label": "WHITE"
      }
    },
    "lang": "en-US",
    "notes": [
      {
        "category": "general",
        "text": "This CSAF advisory was extracted from unstructured data and may contain inaccuracies. If you notice any errors, please reach out to the designated contact at CISA CSAF: central@cisa.dhs.gov",
        "title": "CISA Disclaimer"
      },
      {
        "category": "summary",
        "text": "Younes Dragoni and Alessandro Di Pinto from Nozomi Networks and Artem Zinenko from Kaspersky reported these vulnerability details to Siemens.",
        "title": "Summary"
      },
      {
        "category": "other",
        "text": "No known public exploits specifically target this vulnerability.",
        "title": "Exploitability"
      }
    ],
    "publisher": {
      "category": "coordinator",
      "contact_details": "CISAservicedesk@cisa.dhs.gov",
      "name": "CISA",
      "namespace": "https://www.cisa.gov/"
    },
    "references": [
      {
        "category": "self",
        "summary": "ICS Advisory ICSA-19-225-03 JSON",
        "url": "https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2019/icsa-19-225-03.json"
      },
      {
        "category": "self",
        "summary": "ICS Advisory ICSA-19-225-03 Web Version",
        "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-19-225-03"
      }
    ],
    "title": "ICSA-19-225-03_Siemens SCALANCE X Switches (Update D)",
    "tracking": {
      "current_release_date": "2022-02-10T00:00:00.000000Z",
      "generator": {
        "engine": {
          "name": "CISA USCert CSAF Generator",
          "version": "1"
        }
      },
      "id": "ICSA-19-225-03",
      "initial_release_date": "2019-08-13T00:00:00.000000Z",
      "revision_history": [
        {
          "date": "2019-08-13T00:00:00.000000Z",
          "legacy_version": "Initial",
          "number": "1",
          "summary": "ICSA-19-225-03 Siemens SCALANCE X Switches"
        },
        {
          "date": "2019-08-20T00:00:00.000000Z",
          "legacy_version": "A",
          "number": "2",
          "summary": "ICSA-19-225-03 Siemens SCALANCE X Switches (Update A)"
        },
        {
          "date": "2021-02-09T00:00:00.000000Z",
          "legacy_version": "B",
          "number": "3",
          "summary": "ICSA-19-225-03 Siemens SCALANCE X Switches (Update B)"
        },
        {
          "date": "2021-09-14T00:00:00.000000Z",
          "legacy_version": "C",
          "number": "4",
          "summary": "ICSA-19-225-03 Siemens SCALANCE X Switches (Update C)"
        },
        {
          "date": "2022-02-10T00:00:00.000000Z",
          "legacy_version": "D",
          "number": "5",
          "summary": "ICSA-19-225-03 Siemens SCALANCE X Switches (Update D)"
        }
      ],
      "status": "final",
      "version": "5"
    }
  },
  "product_tree": {
    "branches": [
      {
        "branches": [
          {
            "branches": [
              {
                "category": "product_version",
                "name": "vers:all/*",
                "product": {
                  "name": "SCALANCE X-200RNA: All versions",
                  "product_id": "CSAFPID-0001"
                }
              }
            ],
            "category": "product_name",
            "name": "SCALANCE X-200RNA"
          },
          {
            "branches": [
              {
                "category": "product_version",
                "name": "vers:all/*",
                "product": {
                  "name": "SCALANCE X204RNA EEC (PRP) (6GK5204-0BS00-3LA3): All versions",
                  "product_id": "CSAFPID-0002"
                }
              }
            ],
            "category": "product_name",
            "name": "SCALANCE X204RNA EEC (PRP) (6GK5204-0BS00-3LA3)"
          },
          {
            "branches": [
              {
                "category": "product_version",
                "name": "vers:all/*",
                "product": {
                  "name": "SCALANCE X204RNA (PRP) (6GK5204-0BA00-2KB2): All versions",
                  "product_id": "CSAFPID-0003"
                }
              }
            ],
            "category": "product_name",
            "name": "SCALANCE X204RNA (PRP) (6GK5204-0BA00-2KB2)"
          },
          {
            "branches": [
              {
                "category": "product_version",
                "name": "vers:all/*",
                "product": {
                  "name": "SCALANCE X204RNA (HSR) (6GK5204-0BA00-2MB2): All versions",
                  "product_id": "CSAFPID-0004"
                }
              }
            ],
            "category": "product_name",
            "name": "SCALANCE X204RNA (HSR) (6GK5204-0BA00-2MB2)"
          },
          {
            "branches": [
              {
                "category": "product_version",
                "name": "vers:all/*",
                "product": {
                  "name": "SCALANCE X204RNA EEC (PRP/HSR) (6GK5204-0BS00-3PA3): All versions",
                  "product_id": "CSAFPID-0005"
                }
              }
            ],
            "category": "product_name",
            "name": "SCALANCE X204RNA EEC (PRP/HSR) (6GK5204-0BS00-3PA3)"
          },
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "\u003c 5.5.0",
                "product": {
                  "name": "SCALANCE X-200IRT switch family (incl. SIPLUS NET variants): All versions prior to 5.5.0",
                  "product_id": "CSAFPID-0006"
                }
              }
            ],
            "category": "product_name",
            "name": "SCALANCE X-200IRT switch family (incl. SIPLUS NET variants)"
          },
          {
            "branches": [
              {
                "category": "product_version",
                "name": "vers:all/*",
                "product": {
                  "name": "SCALANCE X204RNA EEC (HSR) (6GK5204-0BS00-2NA3): All versions",
                  "product_id": "CSAFPID-0007"
                }
              }
            ],
            "category": "product_name",
            "name": "SCALANCE X204RNA EEC (HSR) (6GK5204-0BS00-2NA3)"
          }
        ],
        "category": "vendor",
        "name": "Siemens"
      }
    ]
  },
  "vulnerabilities": [
    {
      "cve": "CVE-2019-10942",
      "cwe": {
        "id": "CWE-410",
        "name": "Insufficient Resource Pool"
      },
      "notes": [
        {
          "category": "summary",
          "text": "An attacker may send large message packages repeatedly to the telnet service, which may allow a denial-of-service condition.CVE-2019-10942 has been assigned to this vulnerability. A CVSS v3 base score of 8.6 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:C/C:N/I:N/A:H).",
          "title": "Summary"
        }
      ],
      "product_status": {
        "known_affected": [
          "CSAFPID-0001"
        ]
      },
      "references": [
        {
          "summary": "www.first.org",
          "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:C/C:N/I:N/A:H"
        }
      ],
      "remediations": [
        {
          "category": "mitigation",
          "details": "Siemens recommends users configure their environment according to Siemens \u0027 operational guidelines for industrial security and follow the recommendations in the product manuals.",
          "product_ids": [
            "CSAFPID-0001",
            "CSAFPID-0002",
            "CSAFPID-0003",
            "CSAFPID-0004",
            "CSAFPID-0005",
            "CSAFPID-0006",
            "CSAFPID-0007"
          ],
          "url": "https://cert-portal.siemens.com/operational-guidelines-industrial-security.pdf"
        }
      ],
      "scores": [
        {
          "cvss_v3": {
            "baseScore": 8.6,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:C/C:N/I:N/A:H",
            "version": "3.0"
          },
          "products": [
            "CSAFPID-0001",
            "CSAFPID-0002",
            "CSAFPID-0003",
            "CSAFPID-0004",
            "CSAFPID-0005",
            "CSAFPID-0006",
            "CSAFPID-0007"
          ]
        }
      ],
      "title": "CVE-2019-10942"
    }
  ]
}



Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Drag nodes to arrange them. Double-click a related vulnerability to open it, or a source to visit its link. The Physics button on the left tunes the layout and the simulation; the legend at the bottom left hides or shows nodes by kind and by sighting type.

Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.

Sightings

Author Source Type Date Other

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Vulnerability timeline

Sightings and recorded dates, grouped by day · UTC

JSON
How durations are calculated

Following the VTEM framework (Black Hat USA 2015), time to patch starts when the vendor or a coordinator was informed, total time to patch at discovery, and disclosure to patch at public disclosure; vendor response time runs from the report to its acknowledgement. Time to exploit and time unpatched start at the earliest discovery or report, falling back to public disclosure. Unpatched time ends at the first recorded patch, or the calculation time when no patch is recorded. Exploitation to patch shows the interval between those two events; a published proof of concept is a public exploit, not exploitation.

Each result shows its source dates. A negative interval means the end event came first; when date-only inputs leave the order open, the result says so. Date-only inputs are approximate. The earliest evidence wins: KEV report dates and sightings are labelled as such. Records describing another vulnerability are listed but never calculated from, and a PoC alone does not establish exploitation. Missing patch evidence does not prove that no patch exists. Filters below change the event list only.

Events included in the timeline

Loading timeline…


    Loading…

    Loading…

    Loading…

    Related by attack behaviour

    Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.