ICSA-18-158-01
Vulnerability from csaf_cisa - Published: 2018-06-07 00:00 - Updated: 2018-06-07 00:00| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
RSLinx Classic: Versions 3.90.01 and prior
Rockwell Automation / RSLinx Classic
|
<= 3.90.01 |
Mitigation
fix
Vendor Fix
fix
Mitigation
fix
Mitigation
Mitigation
fix
Mitigation
Mitigation
fix
|
|
|
FactoryTalk Linx Gateway: Versions 3.90.00 and prior
Rockwell Automation / FactoryTalk Linx Gateway
|
<= 3.90.00 |
Mitigation
fix
Vendor Fix
fix
Mitigation
fix
Mitigation
Mitigation
fix
Mitigation
Mitigation
fix
|
{
"document": {
"acknowledgments": [
{
"names": [
"Gjoko Krstic"
],
"organization": "Zero Science Lab",
"summary": "reporting this vulnerability to Rockwell Automation"
},
{
"organization": "Rockwell Automation",
"summary": "reporting it to the NCCIC"
}
],
"category": "csaf_security_advisory",
"csaf_version": "2.0",
"distribution": {
"text": "Disclosure is not limited",
"tlp": {
"label": "WHITE",
"url": "https://us-cert.cisa.gov/tlp/"
}
},
"lang": "en-US",
"notes": [
{
"category": "general",
"text": "This CSAF advisory was extracted from unstructured data and may contain inaccuracies. If you notice any errors, please reach out to the designated contact at CISA CSAF: central@cisa.dhs.gov",
"title": "CISA Disclaimer"
},
{
"category": "legal_disclaimer",
"text": "All information products included in https://us-cert.cisa.gov/ics are provided \"as is\" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.",
"title": "Legal Notice"
},
{
"category": "summary",
"text": "Successful exploitation of this vulnerability could allow an authorized, but non-privileged local user to execute arbitrary code and allow a threat actor to escalate user privileges on the affected workstation.",
"title": "Risk evaluation"
},
{
"category": "other",
"text": "Critical Manufacturing, Energy, Water and Wastewater Systems",
"title": "Critical infrastructure sectors"
},
{
"category": "other",
"text": "Worldwide",
"title": "Countries/areas deployed"
},
{
"category": "other",
"text": "Wisconsin, USA",
"title": "Company headquarters location"
},
{
"category": "general",
"text": "NCCIC recommends users take defensive measures to minimize the risk of exploitation of this vulnerability. Specifically, users should:",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "NCCIC reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.NCCIC also provides a section for control systems security recommended practices on the ICS-CERT web page. Several recommended practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "Additional mitigation guidance and recommended practices are publicly available on the ICS-CERT website in the Technical Information Paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.Organizations observing any suspected malicious activity should follow their established internal procedures and report their findings to NCCIC for tracking and correlation against other incidents.",
"title": "Recommended Practices"
},
{
"category": "other",
"text": "No known public exploits specifically target this vulnerability. This vulnerability is not exploitable remotely.",
"title": "Exploitability"
}
],
"publisher": {
"category": "coordinator",
"contact_details": "Email: CISAservicedesk@cisa.dhs.gov;\n Toll Free: 1-888-282-0870",
"name": "CISA",
"namespace": "https://www.cisa.gov/"
},
"references": [
{
"category": "self",
"summary": "ICS Advisory ICSA-18-158-01 JSON",
"url": "https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2018/icsa-18-158-01.json"
},
{
"category": "self",
"summary": "ICS Advisory ICSA-18-158-01 Web Version",
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-18-158-01"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/uscert/ics/alerts/ICS-ALERT-10-301-01"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/uscert/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/uscert/ics/tips/ICS-TIP-12-146-01B"
}
],
"title": "Rockwell Automation RSLinx Classic and FactoryTalk Linx Gateway",
"tracking": {
"current_release_date": "2018-06-07T00:00:00.000000Z",
"generator": {
"engine": {
"name": "CISA CSAF Generator",
"version": "1.0.0"
}
},
"id": "ICSA-18-158-01",
"initial_release_date": "2018-06-07T00:00:00.000000Z",
"revision_history": [
{
"date": "2018-06-07T00:00:00.000000Z",
"legacy_version": "Initial",
"number": "1",
"summary": "ICSA-18-158-01 Rockwell Automation RSLinx Classic and FactoryTalk Linx Gateway"
}
],
"status": "final",
"version": "1"
}
},
"product_tree": {
"branches": [
{
"branches": [
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c= 3.90.01",
"product": {
"name": "RSLinx Classic: Versions 3.90.01 and prior",
"product_id": "CSAFPID-0001"
}
}
],
"category": "product_name",
"name": "RSLinx Classic"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c= 3.90.00",
"product": {
"name": "FactoryTalk Linx Gateway: Versions 3.90.00 and prior",
"product_id": "CSAFPID-0002"
}
}
],
"category": "product_name",
"name": "FactoryTalk Linx Gateway"
}
],
"category": "vendor",
"name": "Rockwell Automation"
}
]
},
"vulnerabilities": [
{
"cve": "CVE-2018-10619",
"cwe": {
"id": "CWE-428",
"name": "Unquoted Search Path or Element"
},
"notes": [
{
"category": "summary",
"text": "An unquoted search path or element may allow an authorized, but non-privileged local user to execute arbitrary code and allow a threat actor to escalate user privileges on the affected workstation.CVE-2018-10619 has been assigned to this vulnerability. A CVSS v3 base score of 8.8 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H).",
"title": "Vulnerability Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002"
]
},
"references": [
{
"category": "external",
"summary": "web.nvd.nist.gov",
"url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2018-10619"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H"
}
],
"remediations": [
{
"category": "mitigation",
"details": "RSLinx Classic Versions 3.90.01 and prior, update to v4.00.01 or later available at:",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
],
"url": "https://compatibility.rockwellautomation.com/Pages/MultiProductDownload.aspx?crumb=112"
},
{
"category": "vendor_fix",
"details": "FactoryTalk Linx Gateway Versions 3.90.00 and prior, update to FactoryTalk Linx Gateway v6.00.00 or later available at:",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
],
"url": "https://compatibility.rockwellautomation.com/Pages/MultiProductDownload.aspx?crumb=112"
},
{
"category": "mitigation",
"details": "Visit Knowledge Base Article ID 939382, which describes how to identify whether or not the service path contains spaces (i.e., is vulnerable); how to manually address this vulnerability through a registry edit; and describes the process of implementing these edits.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
],
"url": "https://rockwellautomation.custhelp.com/app/answers/detail/a_id/939382"
},
{
"category": "mitigation",
"details": "Run all software as a user, not as an administrator, to minimize the impact of malicious code on the infected system.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
]
},
{
"category": "mitigation",
"details": "Use Microsoft AppLocker or other similar whitelisting application to help mitigate risk. Information on using AppLocker with Rockwell Automation products is available at:",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
],
"url": "https://rockwellautomation.custhelp.com/app/answers/detail/a_id/546989"
},
{
"category": "mitigation",
"details": "Ensure the least-privilege user principle is followed, and user/service account access to shared resources (such as a database) is only granted with a minimum amount of rights as needed.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
]
},
{
"category": "mitigation",
"details": "For more information, please see Rockwell Automation\u0027s knowledgebase advisory number 1073800 on this issue at the following location:",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
],
"url": "https://rockwellautomation.custhelp.com/app/answers/detail/a_id/1073800"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H",
"version": "3.0"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002"
]
}
]
}
]
}
Drag nodes to arrange them. Double-click a related vulnerability to open it, or a source to visit its link. The Physics button on the left tunes the layout and the simulation; the legend at the bottom left hides or shows nodes by kind and by sighting type.
Sightings
| Author | Source | Type | Date | Other |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Vulnerability timeline
Sightings and recorded dates, grouped by day · UTC
How durations are calculated
Following the VTEM framework (Black Hat USA 2015), time to patch starts when the vendor or a coordinator was informed, total time to patch at discovery, and disclosure to patch at public disclosure; vendor response time runs from the report to its acknowledgement. Time to exploit and time unpatched start at the earliest discovery or report, falling back to public disclosure. Unpatched time ends at the first recorded patch, or the calculation time when no patch is recorded. Exploitation to patch shows the interval between those two events; a published proof of concept is a public exploit, not exploitation.
Each result shows its source dates. A negative interval means the end event came first; when date-only inputs leave the order open, the result says so. Date-only inputs are approximate. The earliest evidence wins: KEV report dates and sightings are labelled as such. Records describing another vulnerability are listed but never calculated from, and a PoC alone does not establish exploitation. Missing patch evidence does not prove that no patch exists. Filters below change the event list only.
Loading timeline…
The approach is described in our paper Mapping CVEs to MITRE ATT&CK Techniques: A Curated Gold-Set Classifier and the Limits of LLM-Assisted Label Expansion.
Browse all ATT&CK techniques and the vulnerabilities related to each.
Related by attack behaviour
Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.