Buffer Copy without Checking Size of Input ('Classic Buffer Overflow') vulnerability in Mitsubishi Electric Corporation MELSEC iQ-F Series CPU modules and MELSEC iQ-R Series CPU modules allows a remote unauthenticated attacker to cause a denial of service (DoS) condition or execute malicious code on a target product by sending specially crafted packets. A system reset of the product is required for recovery from a denial of service (DoS) condition and malicious code execution.
Aliases
Aliases

{
  "GSD": {
    "alias": "CVE-2023-1424",
    "id": "GSD-2023-1424"
  },
  "gsd": {
    "metadata": {
      "exploitCode": "unknown",
      "remediation": "unknown",
      "reportConfidence": "confirmed",
      "type": "vulnerability"
    },
    "osvSchema": {
      "aliases": [
        "CVE-2023-1424"
      ],
      "details": "Buffer Copy without Checking Size of Input (\u0027Classic Buffer Overflow\u0027) vulnerability in Mitsubishi Electric Corporation MELSEC iQ-F Series CPU modules and MELSEC iQ-R Series CPU modules allows a remote unauthenticated attacker to cause a denial of service (DoS) condition or execute malicious code on a target product by sending specially crafted packets. A system reset of the product is required for recovery from a denial of service (DoS) condition and malicious code execution.",
      "id": "GSD-2023-1424",
      "modified": "2023-12-13T01:20:41.152193Z",
      "schema_version": "1.4.0"
    }
  },
  "namespaces": {
    "cve.org": {
      "CVE_data_meta": {
        "ASSIGNER": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp",
        "ID": "CVE-2023-1424",
        "STATE": "PUBLIC"
      },
      "affects": {
        "vendor": {
          "vendor_data": [
            {
              "product": {
                "product_data": [
                  {
                    "product_name": "MELSEC iQ-F Series FX5U-32MT/ES",
                    "version": {
                      "version_data": [
                        {
                          "version_affected": "=",
                          "version_value": "Serial number 17X**** or later, versions from 1.220 to 1.281"
                        }
                      ]
                    }
                  },
                  {
                    "product_name": "MELSEC iQ-F Series FX5U-64MT/ES",
                    "version": {
                      "version_data": [
                        {
                          "version_affected": "=",
                          "version_value": "Serial number 17X**** or later, versions from 1.220 to 1.281"
                        }
                      ]
                    }
                  },
                  {
                    "product_name": "MELSEC iQ-F Series FX5U-80MT/ES",
                    "version": {
                      "version_data": [
                        {
                          "version_affected": "=",
                          "version_value": "Serial number 17X**** or later, versions from 1.220 to 1.281"
                        }
                      ]
                    }
                  },
                  {
                    "product_name": "MELSEC iQ-F Series FX5U-32MR/ES",
                    "version": {
                      "version_data": [
                        {
                          "version_affected": "=",
                          "version_value": "Serial number 17X**** or later, versions from 1.220 to 1.281"
                        }
                      ]
                    }
                  },
                  {
                    "product_name": "MELSEC iQ-F Series FX5U-64MR/ES",
                    "version": {
                      "version_data": [
                        {
                          "version_affected": "=",
                          "version_value": "Serial number 17X**** or later, versions from 1.220 to 1.281"
                        }
                      ]
                    }
                  },
                  {
                    "product_name": "MELSEC iQ-F Series FX5U-80MR/ES",
                    "version": {
                      "version_data": [
                        {
                          "version_affected": "=",
                          "version_value": "Serial number 17X**** or later, versions from 1.220 to 1.281"
                        }
                      ]
                    }
                  },
                  {
                    "product_name": "MELSEC iQ-F Series FX5U-32MT/DS",
                    "version": {
                      "version_data": [
                        {
                          "version_affected": "=",
                          "version_value": "Serial number 17X**** or later, versions from 1.220 to 1.281"
                        }
                      ]
                    }
                  },
                  {
                    "product_name": "MELSEC iQ-F Series FX5U-64MT/DS",
                    "version": {
                      "version_data": [
                        {
                          "version_affected": "=",
                          "version_value": "Serial number 17X**** or later, versions from 1.220 to 1.281"
                        }
                      ]
                    }
                  },
                  {
                    "product_name": "MELSEC iQ-F Series FX5U-80MT/DS",
                    "version": {
                      "version_data": [
                        {
                          "version_affected": "=",
                          "version_value": "Serial number 17X**** or later, versions from 1.220 to 1.281"
                        }
                      ]
                    }
                  },
                  {
                    "product_name": "MELSEC iQ-F Series FX5U-32MR/DS",
                    "version": {
                      "version_data": [
                        {
                          "version_affected": "=",
                          "version_value": "Serial number 17X**** or later, versions from 1.220 to 1.281"
                        }
                      ]
                    }
                  },
                  {
                    "product_name": "MELSEC iQ-F Series FX5U-64MR/DS",
                    "version": {
                      "version_data": [
                        {
                          "version_affected": "=",
                          "version_value": "Serial number 17X**** or later, versions from 1.220 to 1.281"
                        }
                      ]
                    }
                  },
                  {
                    "product_name": "MELSEC iQ-F Series FX5U-80MR/DS",
                    "version": {
                      "version_data": [
                        {
                          "version_affected": "=",
                          "version_value": "Serial number 17X**** or later, versions from 1.220 to 1.281"
                        }
                      ]
                    }
                  },
                  {
                    "product_name": "MELSEC iQ-F Series FX5U-32MT/ESS",
                    "version": {
                      "version_data": [
                        {
                          "version_affected": "=",
                          "version_value": "Serial number 17X**** or later, versions from 1.220 to 1.281"
                        }
                      ]
                    }
                  },
                  {
                    "product_name": "MELSEC iQ-F Series FX5U-64MT/ESS",
                    "version": {
                      "version_data": [
                        {
                          "version_affected": "=",
                          "version_value": "Serial number 17X**** or later, versions from 1.220 to 1.281"
                        }
                      ]
                    }
                  },
                  {
                    "product_name": "MELSEC iQ-F Series FX5U-80MT/ESS",
                    "version": {
                      "version_data": [
                        {
                          "version_affected": "=",
                          "version_value": "Serial number 17X**** or later, versions from 1.220 to 1.281"
                        }
                      ]
                    }
                  },
                  {
                    "product_name": "MELSEC iQ-F Series FX5U-32MT/DSS",
                    "version": {
                      "version_data": [
                        {
                          "version_affected": "=",
                          "version_value": "Serial number 17X**** or later, versions from 1.220 to 1.281"
                        }
                      ]
                    }
                  },
                  {
                    "product_name": "MELSEC iQ-F Series FX5U-64MT/DSS",
                    "version": {
                      "version_data": [
                        {
                          "version_affected": "=",
                          "version_value": "Serial number 17X**** or later, versions from 1.220 to 1.281"
                        }
                      ]
                    }
                  },
                  {
                    "product_name": "MELSEC iQ-F Series FX5U-80MT/DSS",
                    "version": {
                      "version_data": [
                        {
                          "version_affected": "=",
                          "version_value": "Serial number 17X**** or later, versions from 1.220 to 1.281"
                        }
                      ]
                    }
                  },
                  {
                    "product_name": "MELSEC iQ-F Series FX5UC-32MT/D",
                    "version": {
                      "version_data": [
                        {
                          "version_affected": "=",
                          "version_value": "Serial number 17X**** or later, versions from 1.220 to 1.281"
                        }
                      ]
                    }
                  },
                  {
                    "product_name": "MELSEC iQ-F Series FX5UC-64MT/D",
                    "version": {
                      "version_data": [
                        {
                          "version_affected": "=",
                          "version_value": "Serial number 17X**** or later, versions from 1.220 to 1.281"
                        }
                      ]
                    }
                  },
                  {
                    "product_name": "MELSEC iQ-F Series FX5UC-96MT/D",
                    "version": {
                      "version_data": [
                        {
                          "version_affected": "=",
                          "version_value": "Serial number 17X**** or later, versions from 1.220 to 1.281"
                        }
                      ]
                    }
                  },
                  {
                    "product_name": "MELSEC iQ-F Series FX5UC-32MT/DSS",
                    "version": {
                      "version_data": [
                        {
                          "version_affected": "=",
                          "version_value": "Serial number 17X**** or later, versions from 1.220 to 1.281"
                        }
                      ]
                    }
                  },
                  {
                    "product_name": "MELSEC iQ-F Series FX5UC-64MT/DSS",
                    "version": {
                      "version_data": [
                        {
                          "version_affected": "=",
                          "version_value": "Serial number 17X**** or later, versions from 1.220 to 1.281"
                        }
                      ]
                    }
                  },
                  {
                    "product_name": "MELSEC iQ-F Series FX5UC-96MT/DSS",
                    "version": {
                      "version_data": [
                        {
                          "version_affected": "=",
                          "version_value": "Serial number 17X**** or later, versions from 1.220 to 1.281"
                        }
                      ]
                    }
                  },
                  {
                    "product_name": "MELSEC iQ-F Series FX5UC-32MT/DS-TS",
                    "version": {
                      "version_data": [
                        {
                          "version_affected": "=",
                          "version_value": "versions from 1.220 to 1.281"
                        }
                      ]
                    }
                  },
                  {
                    "product_name": "MELSEC iQ-F Series FX5UC-32MT/DSS-TS",
                    "version": {
                      "version_data": [
                        {
                          "version_affected": "=",
                          "version_value": "versions from 1.220 to 1.281"
                        }
                      ]
                    }
                  },
                  {
                    "product_name": "MELSEC iQ-F Series FX5UC-32MR/DS-TS",
                    "version": {
                      "version_data": [
                        {
                          "version_affected": "=",
                          "version_value": "versions from 1.220 to 1.281"
                        }
                      ]
                    }
                  },
                  {
                    "product_name": "MELSEC iQ-R Series R00CPU",
                    "version": {
                      "version_data": [
                        {
                          "version_affected": "=",
                          "version_value": "versions 35 and prior"
                        }
                      ]
                    }
                  },
                  {
                    "product_name": "MELSEC iQ-R Series R01CPU",
                    "version": {
                      "version_data": [
                        {
                          "version_affected": "=",
                          "version_value": "versions 35 and prior"
                        }
                      ]
                    }
                  },
                  {
                    "product_name": "MELSEC iQ-R Series R02CPU",
                    "version": {
                      "version_data": [
                        {
                          "version_affected": "=",
                          "version_value": "versions 35 and prior"
                        }
                      ]
                    }
                  },
                  {
                    "product_name": "MELSEC iQ-R Series R04CPU",
                    "version": {
                      "version_data": [
                        {
                          "version_affected": "=",
                          "version_value": "versions from 12 to 68"
                        }
                      ]
                    }
                  },
                  {
                    "product_name": "MELSEC iQ-R Series R08CPU",
                    "version": {
                      "version_data": [
                        {
                          "version_affected": "=",
                          "version_value": "versions from 12 to 68"
                        }
                      ]
                    }
                  },
                  {
                    "product_name": "MELSEC iQ-R Series R16CPU",
                    "version": {
                      "version_data": [
                        {
                          "version_affected": "=",
                          "version_value": "versions from 12 to 68"
                        }
                      ]
                    }
                  },
                  {
                    "product_name": "MELSEC iQ-R Series R32CPU",
                    "version": {
                      "version_data": [
                        {
                          "version_affected": "=",
                          "version_value": "versions from 12 to 68"
                        }
                      ]
                    }
                  },
                  {
                    "product_name": "MELSEC iQ-R Series R120CPU",
                    "version": {
                      "version_data": [
                        {
                          "version_affected": "=",
                          "version_value": "versions from 12 to 68"
                        }
                      ]
                    }
                  },
                  {
                    "product_name": "MELSEC iQ-R Series R04ENCPU",
                    "version": {
                      "version_data": [
                        {
                          "version_affected": "=",
                          "version_value": "versions from 12 to 68"
                        }
                      ]
                    }
                  },
                  {
                    "product_name": "MELSEC iQ-R Series R08ENCPU",
                    "version": {
                      "version_data": [
                        {
                          "version_affected": "=",
                          "version_value": "versions from 12 to 68"
                        }
                      ]
                    }
                  },
                  {
                    "product_name": "MELSEC iQ-R Series R16ENCPU",
                    "version": {
                      "version_data": [
                        {
                          "version_affected": "=",
                          "version_value": "versions from 12 to 68"
                        }
                      ]
                    }
                  },
                  {
                    "product_name": "MELSEC iQ-R Series R32ENCPU",
                    "version": {
                      "version_data": [
                        {
                          "version_affected": "=",
                          "version_value": "versions from 12 to 68"
                        }
                      ]
                    }
                  },
                  {
                    "product_name": "MELSEC iQ-R Series R120ENCPU",
                    "version": {
                      "version_data": [
                        {
                          "version_affected": "=",
                          "version_value": "versions from 12 to 68"
                        }
                      ]
                    }
                  },
                  {
                    "product_name": "MELSEC iQ-R Series R08SFCPU",
                    "version": {
                      "version_data": [
                        {
                          "version_affected": "=",
                          "version_value": "versions from 26 to 31"
                        }
                      ]
                    }
                  },
                  {
                    "product_name": "MELSEC iQ-R Series R16SFCPU",
                    "version": {
                      "version_data": [
                        {
                          "version_affected": "=",
                          "version_value": "versions from 26 to 31"
                        }
                      ]
                    }
                  },
                  {
                    "product_name": "MELSEC iQ-R Series R32SFCPU",
                    "version": {
                      "version_data": [
                        {
                          "version_affected": "=",
                          "version_value": "versions from 26 to 31"
                        }
                      ]
                    }
                  },
                  {
                    "product_name": "MELSEC iQ-R Series R120SFCPU",
                    "version": {
                      "version_data": [
                        {
                          "version_affected": "=",
                          "version_value": "versions from 26 to 31"
                        }
                      ]
                    }
                  },
                  {
                    "product_name": "MELSEC iQ-R Series R08PCPU",
                    "version": {
                      "version_data": [
                        {
                          "version_affected": "=",
                          "version_value": "versions from 3 to 37"
                        }
                      ]
                    }
                  },
                  {
                    "product_name": "MELSEC iQ-R Series R16PCPU",
                    "version": {
                      "version_data": [
                        {
                          "version_affected": "=",
                          "version_value": "versions from 3 to 37"
                        }
                      ]
                    }
                  },
                  {
                    "product_name": "MELSEC iQ-R Series R32PCPU",
                    "version": {
                      "version_data": [
                        {
                          "version_affected": "=",
                          "version_value": "versions from 3 to 37"
                        }
                      ]
                    }
                  },
                  {
                    "product_name": "MELSEC iQ-R Series R120PCPU",
                    "version": {
                      "version_data": [
                        {
                          "version_affected": "=",
                          "version_value": "versions from 3 to 37"
                        }
                      ]
                    }
                  }
                ]
              },
              "vendor_name": "Mitsubishi Electric Corporation"
            }
          ]
        }
      },
      "data_format": "MITRE",
      "data_type": "CVE",
      "data_version": "4.0",
      "description": {
        "description_data": [
          {
            "lang": "eng",
            "value": "Buffer Copy without Checking Size of Input (\u0027Classic Buffer Overflow\u0027) vulnerability in Mitsubishi Electric Corporation MELSEC iQ-F Series CPU modules and MELSEC iQ-R Series CPU modules allows a remote unauthenticated attacker to cause a denial of service (DoS) condition or execute malicious code on a target product by sending specially crafted packets. A system reset of the product is required for recovery from a denial of service (DoS) condition and malicious code execution."
          }
        ]
      },
      "generator": {
        "engine": "Vulnogram 0.1.0-dev"
      },
      "impact": {
        "cvss": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 10,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "CHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H",
            "version": "3.1"
          }
        ]
      },
      "problemtype": {
        "problemtype_data": [
          {
            "description": [
              {
                "cweId": "CWE-120",
                "lang": "eng",
                "value": "CWE-120 Buffer Copy without Checking Size of Input (\u0027Classic Buffer Overflow\u0027)"
              }
            ]
          }
        ]
      },
      "references": {
        "reference_data": [
          {
            "name": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2023-003_en.pdf",
            "refsource": "MISC",
            "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2023-003_en.pdf"
          },
          {
            "name": "https://jvn.jp/vu/JVNVU94650413",
            "refsource": "MISC",
            "url": "https://jvn.jp/vu/JVNVU94650413"
          },
          {
            "name": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-143-03",
            "refsource": "MISC",
            "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-143-03"
          }
        ]
      },
      "source": {
        "discovery": "UNKNOWN"
      }
    },
    "nvd.nist.gov": {
      "configurations": {
        "CVE_data_version": "4.0",
        "nodes": [
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:mitsubishielectric:melsec_iq-fx5u-32mr\\/ds_firmware:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:mitsubishielectric:melsec_iq-fx5u-32mr\\/ds:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:mitsubishielectric:melsec_iq-fx5u-32mr\\/dss_firmware:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:mitsubishielectric:melsec_iq-fx5u-32mr\\/dss:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:mitsubishielectric:melsec_iq-fx5u-32mr\\/es_firmware:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:mitsubishielectric:melsec_iq-fx5u-32mr\\/es:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:mitsubishielectric:melsec_iq-fx5u-32mr\\/ess_firmware:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:mitsubishielectric:melsec_iq-fx5u-32mr\\/ess:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:mitsubishielectric:melsec_iq-fx5u-32mt\\/ds_firmware:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:mitsubishielectric:melsec_iq-fx5u-32mt\\/ds:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:mitsubishielectric:melsec_iq-fx5u-32mt\\/dss_firmware:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:mitsubishielectric:melsec_iq-fx5u-32mt\\/dss:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:mitsubishielectric:melsec_iq-fx5u-32mt\\/es_firmware:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:mitsubishielectric:melsec_iq-fx5u-32mt\\/es:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:mitsubishielectric:melsec_iq-fx5u-32mt\\/ess_firmware:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:mitsubishielectric:melsec_iq-fx5u-32mt\\/ess:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:mitsubishielectric:melsec_iq-fx5u-64mr\\/ds_firmware:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:mitsubishielectric:melsec_iq-fx5u-64mr\\/ds:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:mitsubishielectric:melsec_iq-fx5u-64mr\\/dss_firmware:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:mitsubishielectric:melsec_iq-fx5u-64mr\\/dss:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:mitsubishielectric:melsec_iq-fx5u-64mr\\/es_firmware:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:mitsubishielectric:melsec_iq-fx5u-64mr\\/es:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:mitsubishielectric:melsec_iq-fx5u-64mr\\/ess_firmware:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:mitsubishielectric:melsec_iq-fx5u-64mr\\/ess:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:mitsubishielectric:melsec_iq-fx5u-64mt\\/ds_firmware:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:mitsubishielectric:melsec_iq-fx5u-64mt\\/ds:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:mitsubishielectric:melsec_iq-fx5u-64mt\\/dss_firmware:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:mitsubishielectric:melsec_iq-fx5u-64mt\\/dss:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:mitsubishielectric:melsec_iq-fx5u-64mt\\/es_firmware:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:mitsubishielectric:melsec_iq-fx5u-64mt\\/es:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:mitsubishielectric:melsec_iq-fx5u-64mt\\/ess_firmware:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:mitsubishielectric:melsec_iq-fx5u-64mt\\/ess:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:mitsubishielectric:melsec_iq-fx5u-80mr\\/ds_firmware:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:mitsubishielectric:melsec_iq-fx5u-80mr\\/ds:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:mitsubishielectric:melsec_iq-fx5u-80mr\\/dss_firmware:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:mitsubishielectric:melsec_iq-fx5u-80mr\\/dss:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:mitsubishielectric:melsec_iq-fx5u-80mr\\/es_firmware:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:mitsubishielectric:melsec_iq-fx5u-80mr\\/es:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:mitsubishielectric:melsec_iq-fx5u-80mr\\/ess_firmware:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:mitsubishielectric:melsec_iq-fx5u-80mr\\/ess:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:mitsubishielectric:melsec_iq-fx5u-80mt\\/ds_firmware:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:mitsubishielectric:melsec_iq-fx5u-80mt\\/ds:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:mitsubishielectric:melsec_iq-fx5u-80mt\\/dss_firmware:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:mitsubishielectric:melsec_iq-fx5u-80mt\\/dss:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:mitsubishielectric:melsec_iq-fx5u-80mt\\/es_firmware:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:mitsubishielectric:melsec_iq-fx5u-80mt\\/es:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:mitsubishielectric:melsec_iq-fx5u-80mt\\/ess_firmware:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:mitsubishielectric:melsec_iq-fx5u-80mt\\/ess:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:mitsubishielectric:melsec_iq-fx5uc-32mr\\/dds_firmware:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:mitsubishielectric:melsec_iq-fx5uc-32mr\\/dds:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:mitsubishielectric:melsec_iq-fx5uc-32mr\\/ds_firmware:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:mitsubishielectric:melsec_iq-fx5uc-32mr\\/ds:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:mitsubishielectric:melsec_iq-fx5uc-32mr\\/ds-ts_firmware:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:mitsubishielectric:melsec_iq-fx5uc-32mr\\/ds-ts:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:mitsubishielectric:melsec_iq-fx5uc-32mt\\/dds_firmware:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:mitsubishielectric:melsec_iq-fx5uc-32mt\\/dds:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:mitsubishielectric:melsec_iq-fx5uc-32mt\\/ds_firmware:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:mitsubishielectric:melsec_iq-fx5uc-32mt\\/ds:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:mitsubishielectric:melsec_iq-fx5uc-32mt\\/dss-ts_firmware:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:mitsubishielectric:melsec_iq-fx5uc-32mt\\/dss-ts:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:mitsubishielectric:melsec_iq-fx5uc-32mt\\/ds-ts_firmware:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:mitsubishielectric:melsec_iq-fx5uc-32mt\\/ds-ts:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:mitsubishielectric:melsec_iq-fx5uc-64mr\\/dds_firmware:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:mitsubishielectric:melsec_iq-fx5uc-64mr\\/dds:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:mitsubishielectric:melsec_iq-fx5uc-64mr\\/ds_firmware:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:mitsubishielectric:melsec_iq-fx5uc-64mr\\/ds:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:mitsubishielectric:melsec_iq-fx5uc-64mt\\/dds_firmware:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:mitsubishielectric:melsec_iq-fx5uc-64mt\\/dds:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:mitsubishielectric:melsec_iq-fx5uc-64mt\\/ds_firmware:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:mitsubishielectric:melsec_iq-fx5uc-64mt\\/ds:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:mitsubishielectric:melsec_iq-fx5uc-96mr\\/dds_firmware:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:mitsubishielectric:melsec_iq-fx5uc-96mr\\/dds:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:mitsubishielectric:melsec_iq-fx5uc-96mr\\/ds_firmware:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:mitsubishielectric:melsec_iq-fx5uc-96mr\\/ds:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:mitsubishielectric:melsec_iq-fx5uc-96mt\\/dds_firmware:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:mitsubishielectric:melsec_iq-fx5uc-96mt\\/dds:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:mitsubishielectric:melsec_iq-fx5uc-96mt\\/ds_firmware:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:mitsubishielectric:melsec_iq-fx5uc-96mt\\/ds:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          }
        ]
      },
      "cve": {
        "CVE_data_meta": {
          "ASSIGNER": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp",
          "ID": "CVE-2023-1424"
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "en",
              "value": "Buffer Copy without Checking Size of Input (\u0027Classic Buffer Overflow\u0027) vulnerability in Mitsubishi Electric Corporation MELSEC iQ-F Series CPU modules and MELSEC iQ-R Series CPU modules allows a remote unauthenticated attacker to cause a denial of service (DoS) condition or execute malicious code on a target product by sending specially crafted packets. A system reset of the product is required for recovery from a denial of service (DoS) condition and malicious code execution."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "en",
                  "value": "CWE-120"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-143-03",
              "refsource": "MISC",
              "tags": [
                "Third Party Advisory",
                "US Government Resource"
              ],
              "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-143-03"
            },
            {
              "name": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2023-003_en.pdf",
              "refsource": "MISC",
              "tags": [
                "Patch",
                "Vendor Advisory"
              ],
              "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2023-003_en.pdf"
            },
            {
              "name": "https://jvn.jp/vu/JVNVU94650413",
              "refsource": "MISC",
              "tags": [
                "Third Party Advisory"
              ],
              "url": "https://jvn.jp/vu/JVNVU94650413"
            }
          ]
        }
      },
      "impact": {
        "baseMetricV3": {
          "cvssV3": {
            "attackComplexity": "HIGH",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 8.1,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "exploitabilityScore": 2.2,
          "impactScore": 5.9
        }
      },
      "lastModifiedDate": "2023-07-07T04:15Z",
      "publishedDate": "2023-05-24T05:15Z"
    }
  }
}



Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Drag nodes to arrange them. Double-click a related vulnerability to open it, or a source to visit its link. The Physics button on the left tunes the layout and the simulation; the legend at the bottom left hides or shows nodes by kind and by sighting type.

Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.

Sightings

Author Source Type Date Other

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Vulnerability timeline

Sightings and recorded dates, grouped by day · UTC

JSON
How durations are calculated

Following the VTEM framework (Black Hat USA 2015), time to patch starts when the vendor or a coordinator was informed, total time to patch at discovery, and disclosure to patch at public disclosure; vendor response time runs from the report to its acknowledgement. Time to exploit and time unpatched start at the earliest discovery or report, falling back to public disclosure. Unpatched time ends at the first recorded patch, or the calculation time when no patch is recorded. Exploitation to patch shows the interval between those two events; a published proof of concept is a public exploit, not exploitation.

Each result shows its source dates. A negative interval means the end event came first; when date-only inputs leave the order open, the result says so. Date-only inputs are approximate. The earliest evidence wins: KEV report dates and sightings are labelled as such. Records describing another vulnerability are listed but never calculated from, and a PoC alone does not establish exploitation. Missing patch evidence does not prove that no patch exists. Filters below change the event list only.

Events included in the timeline

Loading timeline…


    Loading…

    Loading…

    Loading…

    Related by attack behaviour

    Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.