GSD-2022-2967
Vulnerability from gsd - Updated: 2023-12-13 01:19Details
Prosys OPC UA Simulation Server version prior to v5.3.0-64 and UA Modbus Server versions 1.4.18-5 and prior do not sufficiently protect credentials, which could allow an attacker to obtain user credentials and gain access to system data.
Aliases
Aliases
{
"GSD": {
"alias": "CVE-2022-2967",
"description": "Prosys OPC UA Simulation Server version prior to v5.3.0-64 and UA Modbus Server versions 1.4.18-5 and prior do not sufficiently protect credentials, which could allow an attacker to obtain user credentials and gain access to system data.",
"id": "GSD-2022-2967"
},
"gsd": {
"metadata": {
"exploitCode": "unknown",
"remediation": "unknown",
"reportConfidence": "confirmed",
"type": "vulnerability"
},
"osvSchema": {
"aliases": [
"CVE-2022-2967"
],
"details": "Prosys OPC UA Simulation Server version prior to v5.3.0-64 and UA Modbus Server versions 1.4.18-5 and prior do not sufficiently protect credentials, which could allow an attacker to obtain user credentials and gain access to system data.",
"id": "GSD-2022-2967",
"modified": "2023-12-13T01:19:20.362506Z",
"schema_version": "1.4.0"
}
},
"namespaces": {
"cve.org": {
"CVE_data_meta": {
"ASSIGNER": "ics-cert@hq.dhs.gov",
"ID": "CVE-2022-2967",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "UA Simulation Server",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "0"
}
]
}
},
{
"product_name": "UA Modbus Server",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "0"
}
]
}
}
]
},
"vendor_name": "Prosys OPC"
}
]
}
},
"credits": [
{
"lang": "en",
"value": "Parvin Kumar, Dr. Sriharsha Etigowni, and Prof. Dongyan Xu of Purdue University West Lafayette reported this vulnerability to CISA."
}
],
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Prosys OPC UA Simulation Server version prior to v5.3.0-64 and UA Modbus Server versions 1.4.18-5 and prior do not sufficiently protect credentials, which could allow an attacker to obtain user credentials and gain access to system data."
}
]
},
"generator": {
"engine": "Vulnogram 0.1.0-dev"
},
"impact": {
"cvss": [
{
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"cweId": "CWE-522",
"lang": "eng",
"value": "CWE-522 Insufficiently Protected Credentials"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-349-01",
"refsource": "MISC",
"url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-349-01"
},
{
"name": "https://www.prosysopc.com/blog/#Security",
"refsource": "MISC",
"url": "https://www.prosysopc.com/blog/#Security"
}
]
},
"solution": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Prosys has released updates for the following products:\u003cbr\u003e\u2022 UA Simulation Server: Update to v5.4.0\u003cbr\u003e\u2022 UA Modbus Server: Update to 1.4.20\u003cbr\u003e\u003cbr\u003e"
}
],
"value": "Prosys has released updates for the following products:\n\u2022 UA Simulation Server: Update to v5.4.0\n\u2022 UA Modbus Server: Update to 1.4.20\n\n"
}
],
"source": {
"advisory": "ICSA-22-349-01",
"discovery": "EXTERNAL"
},
"work_around": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\n\u003cp\u003eProsys also recommends additional workarounds to mitigate exploitation of this vulnerability:\u003c/p\u003e\n\n\u003cul\u003e\u003cli\u003eRestart the application after modifying user passwords.\u003c/li\u003e\n\u003c/ul\u003e\u003cp\u003eFor more information, users can refer to the Prosys OPC \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://www.prosysopc.com/blog/#Security\"\u003esecurity blog\u003c/a\u003e\u003cspan style=\"background-color: var(--wht);\"\u003e.\u003c/span\u003e\u003c/p\u003e"
}
],
"value": "Prosys also recommends additional workarounds to mitigate exploitation of this vulnerability:\n\n\n\n * Restart the application after modifying user passwords.\n\n\n\nFor more information, users can refer to the Prosys OPC security blog https://www.prosysopc.com/blog/#Security .\n\n"
}
]
},
"nvd.nist.gov": {
"configurations": {
"CVE_data_version": "4.0",
"nodes": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:a:prosysopc:ua_modbus_server:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "1.4.20",
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:prosysopc:ua_simulation_server:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "5.4.0",
"vulnerable": true
}
],
"operator": "OR"
}
]
},
"cve": {
"CVE_data_meta": {
"ASSIGNER": "ics-cert@hq.dhs.gov",
"ID": "CVE-2022-2967"
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "en",
"value": "Prosys OPC UA Simulation Server version prior to v5.3.0-64 and UA Modbus Server versions 1.4.18-5 and prior do not sufficiently protect credentials, which could allow an attacker to obtain user credentials and gain access to system data."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "en",
"value": "CWE-522"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.prosysopc.com/blog/#Security",
"refsource": "MISC",
"tags": [
"Vendor Advisory"
],
"url": "https://www.prosysopc.com/blog/#Security"
},
{
"name": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-349-01",
"refsource": "MISC",
"tags": [
"Patch",
"Third Party Advisory",
"US Government Resource"
],
"url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-349-01"
}
]
}
},
"impact": {
"baseMetricV3": {
"cvssV3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 3.6
}
},
"lastModifiedDate": "2023-01-10T16:38Z",
"publishedDate": "2023-01-03T22:15Z"
}
}
}
Loading…
Loading…
Drag nodes to arrange them. Double-click a related vulnerability to open it, or a source to visit its link. The Physics button on the left tunes the layout and the simulation; the legend at the bottom left hides or shows nodes by kind and by sighting type.
Experimental. This forecast is provided for visualization only and may change without notice. Do not use it for operational decisions.
Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.
Sightings
| Author | Source | Type | Date | Other |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Vulnerability timeline
Sightings and recorded dates, grouped by day · UTC
Loading timeline…
Loading…
Loading…
The MITRE ATT&CK techniques below are AI-generated suggestions, inferred from the description of the
vulnerability by the CIRCL/vulnerability-attack-technique-classification-roberta-base
model, served locally by ML-Gateway.
They have not been verified by an analyst and are provided for guidance only.
The approach is described in our paper Mapping CVEs to MITRE ATT&CK Techniques: A Curated Gold-Set Classifier and the Limits of LLM-Assisted Label Expansion.
Browse all ATT&CK techniques and the vulnerabilities related to each.
The approach is described in our paper Mapping CVEs to MITRE ATT&CK Techniques: A Curated Gold-Set Classifier and the Limits of LLM-Assisted Label Expansion.
Browse all ATT&CK techniques and the vulnerabilities related to each.
Loading…
Related by attack behaviour
Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.