GSD-2021-20999

Vulnerability from gsd - Updated: 2023-12-13 01:23
Details
In Weidmüller u-controls and IoT-Gateways in versions up to 1.12.1 a network port intended only for device-internal usage is accidentally accessible via external network interfaces. By exploiting this vulnerability the device may be manipulated or the operation may be stopped.
Aliases
Aliases

{
  "GSD": {
    "alias": "CVE-2021-20999",
    "description": "In Weidm\u00fcller u-controls and IoT-Gateways in versions up to 1.12.1 a network port intended only for device-internal usage is accidentally accessible via external network interfaces. By exploiting this vulnerability the device may be manipulated or the operation may be stopped.",
    "id": "GSD-2021-20999"
  },
  "gsd": {
    "metadata": {
      "exploitCode": "unknown",
      "remediation": "unknown",
      "reportConfidence": "confirmed",
      "type": "vulnerability"
    },
    "osvSchema": {
      "aliases": [
        "CVE-2021-20999"
      ],
      "details": "In Weidm\u00fcller u-controls and IoT-Gateways in versions up to 1.12.1 a network port intended only for device-internal usage is accidentally accessible via external network interfaces. By exploiting this vulnerability the device may be manipulated or the operation may be stopped.",
      "id": "GSD-2021-20999",
      "modified": "2023-12-13T01:23:12.293967Z",
      "schema_version": "1.4.0"
    }
  },
  "namespaces": {
    "cve.org": {
      "CVE_data_meta": {
        "ASSIGNER": "info@cert.vde.com",
        "DATE_PUBLIC": "2021-05-04T10:00:00.000Z",
        "ID": "CVE-2021-20999",
        "STATE": "PUBLIC",
        "TITLE": "WEIDMUELLER: Accidentally open network port in u-controls and IoT-Gateways"
      },
      "affects": {
        "vendor": {
          "vendor_data": [
            {
              "product": {
                "product_data": [
                  {
                    "product_name": "UC20-WL2000-AC (No. 1334950000)",
                    "version": {
                      "version_data": [
                        {
                          "version_affected": "\u003c=",
                          "version_name": "1.3.0",
                          "version_value": "1.9.0"
                        },
                        {
                          "version_affected": "\u003c=",
                          "version_name": "1.10.0",
                          "version_value": "1.10.2"
                        },
                        {
                          "version_affected": "\u003c=",
                          "version_name": "1.11.0",
                          "version_value": "1.12.1"
                        }
                      ]
                    }
                  },
                  {
                    "product_name": "UC20-WL2000-IOT (No. 1334990000)",
                    "version": {
                      "version_data": [
                        {
                          "version_affected": "\u003c=",
                          "version_name": "1.3.0",
                          "version_value": "1.9.0"
                        },
                        {
                          "version_affected": "\u003c=",
                          "version_name": "1.10.0",
                          "version_value": "1.10.2"
                        },
                        {
                          "version_affected": "\u003c=",
                          "version_name": "1.11.0",
                          "version_value": "1.12.1"
                        }
                      ]
                    }
                  },
                  {
                    "product_name": "IOT-GW30 (No. 2682620000)",
                    "version": {
                      "version_data": [
                        {
                          "version_affected": "\u003c=",
                          "version_name": "1.3.0",
                          "version_value": "1.9.0"
                        },
                        {
                          "version_affected": "\u003c=",
                          "version_name": "1.10.0",
                          "version_value": "1.10.2"
                        },
                        {
                          "version_affected": "\u003c=",
                          "version_name": "1.11.0",
                          "version_value": "1.12.1"
                        }
                      ]
                    }
                  },
                  {
                    "product_name": "IOT-GW30-4G-EU (No. 2682630000)",
                    "version": {
                      "version_data": [
                        {
                          "version_affected": "\u003c=",
                          "version_name": "1.3.0",
                          "version_value": "1.9.0"
                        },
                        {
                          "version_affected": "\u003c=",
                          "version_name": "1.10.0",
                          "version_value": "1.10.2"
                        },
                        {
                          "version_affected": "\u003c=",
                          "version_name": "1.11.0",
                          "version_value": "1.12.1"
                        }
                      ]
                    }
                  }
                ]
              },
              "vendor_name": "Weidm\u00fcller"
            }
          ]
        }
      },
      "credit": [
        {
          "lang": "eng",
          "value": "Reported by Weidm\u00fcller."
        }
      ],
      "data_format": "MITRE",
      "data_type": "CVE",
      "data_version": "4.0",
      "description": {
        "description_data": [
          {
            "lang": "eng",
            "value": "In Weidm\u00fcller u-controls and IoT-Gateways in versions up to 1.12.1 a network port intended only for device-internal usage is accidentally accessible via external network interfaces. By exploiting this vulnerability the device may be manipulated or the operation may be stopped."
          }
        ]
      },
      "generator": {
        "engine": "Vulnogram 0.0.9"
      },
      "impact": {
        "cvss": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 9.4,
          "baseSeverity": "CRITICAL",
          "confidentialityImpact": "LOW",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:H/A:H",
          "version": "3.1"
        }
      },
      "problemtype": {
        "problemtype_data": [
          {
            "description": [
              {
                "lang": "eng",
                "value": "CWE-668 Exposure of Resource to Wrong Sphere"
              }
            ]
          }
        ]
      },
      "references": {
        "reference_data": [
          {
            "name": "https://cert.vde.com/en-us/advisories/vde-2021-016",
            "refsource": "CONFIRM",
            "url": "https://cert.vde.com/en-us/advisories/vde-2021-016"
          }
        ]
      },
      "solution": [
        {
          "lang": "eng",
          "value": "Weidm\u00fcller recommends upgrading affected devices to the current firmware version 1.12.3 or higher which fixes this vulnerability."
        }
      ],
      "source": {
        "advisory": "VDE-2021-016",
        "defect": [
          "VDE-2021-016"
        ],
        "discovery": "INTERNAL"
      },
      "work_around": [
        {
          "lang": "eng",
          "value": "Restrict access to the network the device is connected to.\nDo not directly connect the device to the internet."
        }
      ]
    },
    "nvd.nist.gov": {
      "configurations": {
        "CVE_data_version": "4.0",
        "nodes": [
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:weidmueller:uc20-wl2000-ac_firmware:1.11.0:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  },
                  {
                    "cpe23Uri": "cpe:2.3:o:weidmueller:uc20-wl2000-ac_firmware:1.12.1:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  },
                  {
                    "cpe23Uri": "cpe:2.3:o:weidmueller:uc20-wl2000-ac_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "1.10.3",
                    "versionStartIncluding": "1.10.0",
                    "vulnerable": true
                  },
                  {
                    "cpe23Uri": "cpe:2.3:o:weidmueller:uc20-wl2000-ac_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "1.9.1",
                    "versionStartIncluding": "1.3.0",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:weidmueller:uc20-wl2000-ac:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:weidmueller:uc20-wl2000-iot_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "1.9.1",
                    "versionStartIncluding": "1.3.0",
                    "vulnerable": true
                  },
                  {
                    "cpe23Uri": "cpe:2.3:o:weidmueller:uc20-wl2000-iot_firmware:1.12.1:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  },
                  {
                    "cpe23Uri": "cpe:2.3:o:weidmueller:uc20-wl2000-iot_firmware:1.11.0:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  },
                  {
                    "cpe23Uri": "cpe:2.3:o:weidmueller:uc20-wl2000-iot_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "1.10.3",
                    "versionStartIncluding": "1.10.0",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:weidmueller:uc20-wl2000-iot:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:weidmueller:iot-gw30_firmware:1.11.0:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  },
                  {
                    "cpe23Uri": "cpe:2.3:o:weidmueller:iot-gw30_firmware:1.12.1:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  },
                  {
                    "cpe23Uri": "cpe:2.3:o:weidmueller:iot-gw30_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "1.10.3",
                    "versionStartIncluding": "1.10.0",
                    "vulnerable": true
                  },
                  {
                    "cpe23Uri": "cpe:2.3:o:weidmueller:iot-gw30_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "1.9.1",
                    "versionStartIncluding": "1.3.0",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:weidmueller:iot-gw30:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:weidmueller:iot-gw30-4g-eu_firmware:1.11.0:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  },
                  {
                    "cpe23Uri": "cpe:2.3:o:weidmueller:iot-gw30-4g-eu_firmware:1.12.1:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  },
                  {
                    "cpe23Uri": "cpe:2.3:o:weidmueller:iot-gw30-4g-eu_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "1.10.3",
                    "versionStartIncluding": "1.10.0",
                    "vulnerable": true
                  },
                  {
                    "cpe23Uri": "cpe:2.3:o:weidmueller:iot-gw30-4g-eu_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "1.9.1",
                    "versionStartIncluding": "1.3.0",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:weidmueller:iot-gw30-4g-eu:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          }
        ]
      },
      "cve": {
        "CVE_data_meta": {
          "ASSIGNER": "info@cert.vde.com",
          "ID": "CVE-2021-20999"
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "en",
              "value": "In Weidm\u00c3\u00bcller u-controls and IoT-Gateways in versions up to 1.12.1 a network port intended only for device-internal usage is accidentally accessible via external network interfaces. By exploiting this vulnerability the device may be manipulated or the operation may be stopped."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "en",
                  "value": "NVD-CWE-Other"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://cert.vde.com/en-us/advisories/vde-2021-016",
              "refsource": "CONFIRM",
              "tags": [
                "Third Party Advisory"
              ],
              "url": "https://cert.vde.com/en-us/advisories/vde-2021-016"
            }
          ]
        }
      },
      "impact": {
        "baseMetricV2": {
          "acInsufInfo": false,
          "cvssV2": {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "availabilityImpact": "PARTIAL",
            "baseScore": 7.5,
            "confidentialityImpact": "PARTIAL",
            "integrityImpact": "PARTIAL",
            "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
            "version": "2.0"
          },
          "exploitabilityScore": 10.0,
          "impactScore": 6.4,
          "obtainAllPrivilege": false,
          "obtainOtherPrivilege": false,
          "obtainUserPrivilege": false,
          "severity": "HIGH",
          "userInteractionRequired": false
        },
        "baseMetricV3": {
          "cvssV3": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "exploitabilityScore": 3.9,
          "impactScore": 5.9
        }
      },
      "lastModifiedDate": "2022-10-21T20:02Z",
      "publishedDate": "2021-05-13T14:15Z"
    }
  }
}



Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.

Sightings

Author Source Type Date Other

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.

Loading…

Loading…

Loading…

Related by attack behaviour

Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.


Loading…