GSD-2020-5675

Vulnerability from gsd - Updated: 2023-12-13 01:22
Details
Out-of-bounds read vulnerability in GT21 model of GOT2000 series (GT2107-WTBD V01.39.000 and earlier, GT2107-WTSD V01.39.000 and earlier, GT2104-RTBD V01.39.000 and earlier, GT2104-PMBD V01.39.000 and earlier, and GT2103-PMBD V01.39.000 and earlier), GS21 model of GOT series (GS2110-WTBD V01.39.000 and earlier, GS2107-WTBD V01.39.000 and earlier, GS2110-WTBD-N V01.39.000 and earlier, and GS2107-WTBD-N V01.39.000 and earlier), and Tension Controller LE7-40GU-L series (LE7-40GU-L Screen package data for CC-Link IEF Basic V1.00, LE7-40GU-L Screen package data for MODBUS/TCP V1.00, and LE7-40GU-L Screen package data for SLMP V1.00) allows a remote attacker to cause a denial-of-service (DoS) condition by sending a specially crafted packet. As a result, deterioration of communication performance or a denial-of-service (DoS) condition of the TCP communication functions of the products may occur.
Aliases
Aliases

{
  "GSD": {
    "alias": "CVE-2020-5675",
    "description": "Out-of-bounds read issue in GT21 model of GOT2000 series (GT2107-WTBD all versions, GT2107-WTSD all versions, GT2104-RTBD all versions, GT2104-PMBD all versions, and GT2103-PMBD all versions), GS21 model of GOT series (GS2110-WTBD all versions and GS2107-WTBD all versions), and Tension Controller LE7-40GU-L all versions allows a remote attacker to cause a denial-of-service (DoS) condition by sending a specially crafted packet. As a result, deterioration of communication performance or a denial-of-service (DoS) condition of the TCP communication functions of the products may occur.",
    "id": "GSD-2020-5675"
  },
  "gsd": {
    "metadata": {
      "exploitCode": "unknown",
      "remediation": "unknown",
      "reportConfidence": "confirmed",
      "type": "vulnerability"
    },
    "osvSchema": {
      "aliases": [
        "CVE-2020-5675"
      ],
      "details": "Out-of-bounds read vulnerability in GT21 model of GOT2000 series (GT2107-WTBD V01.39.000 and earlier, GT2107-WTSD V01.39.000 and earlier, GT2104-RTBD V01.39.000 and earlier, GT2104-PMBD V01.39.000 and earlier, and GT2103-PMBD V01.39.000 and earlier), GS21 model of GOT series (GS2110-WTBD V01.39.000 and earlier, GS2107-WTBD V01.39.000 and earlier, GS2110-WTBD-N V01.39.000 and earlier, and GS2107-WTBD-N V01.39.000 and earlier), and Tension Controller LE7-40GU-L series (LE7-40GU-L Screen package data for CC-Link IEF Basic V1.00, LE7-40GU-L Screen package data for MODBUS/TCP V1.00, and LE7-40GU-L Screen package data for SLMP V1.00) allows a remote attacker to cause a denial-of-service (DoS) condition by sending a specially crafted packet. As a result, deterioration of communication performance or a denial-of-service (DoS) condition of the TCP communication functions of the products may occur.",
      "id": "GSD-2020-5675",
      "modified": "2023-12-13T01:22:03.238522Z",
      "schema_version": "1.4.0"
    }
  },
  "namespaces": {
    "cve.org": {
      "CVE_data_meta": {
        "ASSIGNER": "vultures@jpcert.or.jp",
        "ID": "CVE-2020-5675",
        "STATE": "PUBLIC"
      },
      "affects": {
        "vendor": {
          "vendor_data": [
            {
              "product": {
                "product_data": [
                  {
                    "product_name": "GT21 model of GOT2000 series, GS21 model of GOT SIMPLE series, and Tension Controller LE7-40GU-L series",
                    "version": {
                      "version_data": [
                        {
                          "version_value": "GT21 model of GOT2000 series (GT2107-WTBD V01.39.000 and earlier, GT2107-WTSD V01.39.000 and earlier, GT2104-RTBD V01.39.000 and earlier, GT2104-PMBD V01.39.000 and earlier, and GT2103-PMBD V01.39.000 and earlier), GS21 model of GOT series (GS2110-WTBD V01.39.000 and earlier, GS2107-WTBD V01.39.000 and earlier, GS2110-WTBD-N V01.39.000 and earlier, and GS2107-WTBD-N V01.39.000 and earlier), and Tension Controller LE7-40GU-L series (LE7-40GU-L Screen package data for CC-Link IEF Basic V1.00, LE7-40GU-L Screen package data for MODBUS/TCP V1.00, and LE7-40GU-L Screen package data for SLMP V1.00)"
                        }
                      ]
                    }
                  }
                ]
              },
              "vendor_name": "Mitsubishi Electric Corporation"
            }
          ]
        }
      },
      "data_format": "MITRE",
      "data_type": "CVE",
      "data_version": "4.0",
      "description": {
        "description_data": [
          {
            "lang": "eng",
            "value": "Out-of-bounds read vulnerability in GT21 model of GOT2000 series (GT2107-WTBD V01.39.000 and earlier, GT2107-WTSD V01.39.000 and earlier, GT2104-RTBD V01.39.000 and earlier, GT2104-PMBD V01.39.000 and earlier, and GT2103-PMBD V01.39.000 and earlier), GS21 model of GOT series (GS2110-WTBD V01.39.000 and earlier, GS2107-WTBD V01.39.000 and earlier, GS2110-WTBD-N V01.39.000 and earlier, and GS2107-WTBD-N V01.39.000 and earlier), and Tension Controller LE7-40GU-L series (LE7-40GU-L Screen package data for CC-Link IEF Basic V1.00, LE7-40GU-L Screen package data for MODBUS/TCP V1.00, and LE7-40GU-L Screen package data for SLMP V1.00) allows a remote attacker to cause a denial-of-service (DoS) condition by sending a specially crafted packet. As a result, deterioration of communication performance or a denial-of-service (DoS) condition of the TCP communication functions of the products may occur."
          }
        ]
      },
      "problemtype": {
        "problemtype_data": [
          {
            "description": [
              {
                "lang": "eng",
                "value": "Denial-of-service (DoS)"
              }
            ]
          }
        ]
      },
      "references": {
        "reference_data": [
          {
            "name": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2020-017_en.pdf",
            "refsource": "MISC",
            "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2020-017_en.pdf"
          },
          {
            "name": "https://www.mitsubishielectric.co.jp/psirt/vulnerability/pdf/2020-017.pdf",
            "refsource": "MISC",
            "url": "https://www.mitsubishielectric.co.jp/psirt/vulnerability/pdf/2020-017.pdf"
          },
          {
            "name": "https://jvn.jp/vu/JVNVU99277775/index.html",
            "refsource": "MISC",
            "url": "https://jvn.jp/vu/JVNVU99277775/index.html"
          }
        ]
      }
    },
    "nvd.nist.gov": {
      "configurations": {
        "CVE_data_version": "4.0",
        "nodes": [
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:mitsubishielectric:gt2107-wtbd_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndIncluding": "01.39.000",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:mitsubishielectric:gt2107-wtbd:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:mitsubishielectric:gt2107-wtsd_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndIncluding": "01.39.000",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:mitsubishielectric:gt2107-wtsd:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:mitsubishielectric:gt2104-rtbd_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndIncluding": "01.39.000",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:mitsubishielectric:gt2104-rtbd:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:mitsubishielectric:gt2104-pmbd_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndIncluding": "01.39.000",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:mitsubishielectric:gt2104-pmbd:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:mitsubishielectric:gt2103-pmbd_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndIncluding": "01.39.000",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:mitsubishielectric:gt2103-pmbd:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:mitsubishielectric:gs2110-wtbd_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndIncluding": "01.39.000",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:mitsubishielectric:gs2110-wtbd:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:mitsubishielectric:gs2107-wtbd_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndIncluding": "01.39.000",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:mitsubishielectric:gs2107-wtbd:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:mitsubishielectric:le7-40gu-l_firmware:1.00:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:mitsubishielectric:le7-40gu-l:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:mitsubishielectric:gs2110-wtbd-n_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndIncluding": "01.39.000",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:mitsubishielectric:gs2110-wtbd-n:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:mitsubishielectric:gs2107-wtbd-n_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndIncluding": "01.39.000",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:mitsubishielectric:gs2107-wtbd-n:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          }
        ]
      },
      "cve": {
        "CVE_data_meta": {
          "ASSIGNER": "vultures@jpcert.or.jp",
          "ID": "CVE-2020-5675"
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "en",
              "value": "Out-of-bounds read vulnerability in GT21 model of GOT2000 series (GT2107-WTBD V01.39.000 and earlier, GT2107-WTSD V01.39.000 and earlier, GT2104-RTBD V01.39.000 and earlier, GT2104-PMBD V01.39.000 and earlier, and GT2103-PMBD V01.39.000 and earlier), GS21 model of GOT series (GS2110-WTBD V01.39.000 and earlier, GS2107-WTBD V01.39.000 and earlier, GS2110-WTBD-N V01.39.000 and earlier, and GS2107-WTBD-N V01.39.000 and earlier), and Tension Controller LE7-40GU-L series (LE7-40GU-L Screen package data for CC-Link IEF Basic V1.00, LE7-40GU-L Screen package data for MODBUS/TCP V1.00, and LE7-40GU-L Screen package data for SLMP V1.00) allows a remote attacker to cause a denial-of-service (DoS) condition by sending a specially crafted packet. As a result, deterioration of communication performance or a denial-of-service (DoS) condition of the TCP communication functions of the products may occur."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "en",
                  "value": "CWE-125"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.mitsubishielectric.co.jp/psirt/vulnerability/pdf/2020-017.pdf",
              "refsource": "MISC",
              "tags": [
                "Vendor Advisory"
              ],
              "url": "https://www.mitsubishielectric.co.jp/psirt/vulnerability/pdf/2020-017.pdf"
            },
            {
              "name": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2020-017_en.pdf",
              "refsource": "MISC",
              "tags": [
                "Vendor Advisory"
              ],
              "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2020-017_en.pdf"
            },
            {
              "name": "https://jvn.jp/vu/JVNVU99277775/index.html",
              "refsource": "MISC",
              "tags": [
                "Third Party Advisory"
              ],
              "url": "https://jvn.jp/vu/JVNVU99277775/index.html"
            }
          ]
        }
      },
      "impact": {
        "baseMetricV2": {
          "acInsufInfo": false,
          "cvssV2": {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "availabilityImpact": "PARTIAL",
            "baseScore": 5.0,
            "confidentialityImpact": "NONE",
            "integrityImpact": "NONE",
            "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:P",
            "version": "2.0"
          },
          "exploitabilityScore": 10.0,
          "impactScore": 2.9,
          "obtainAllPrivilege": false,
          "obtainOtherPrivilege": false,
          "obtainUserPrivilege": false,
          "severity": "MEDIUM",
          "userInteractionRequired": false
        },
        "baseMetricV3": {
          "cvssV3": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 7.5,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "NONE",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
            "version": "3.1"
          },
          "exploitabilityScore": 3.9,
          "impactScore": 3.6
        }
      },
      "lastModifiedDate": "2022-02-10T07:38Z",
      "publishedDate": "2020-12-04T08:15Z"
    }
  }
}



Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.

Sightings

Author Source Type Date Other

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.

Loading…

Loading…

Loading…

Related by attack behaviour

Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.


Loading…