An issue was discovered on Sigma Design Z-Wave S0 through S2 devices. An attacker first prepares a Z-Wave frame-transmission program (e.g., Z-Wave PC Controller, OpenZWave, CC1110, etc.). Next, the attacker conducts a DoS attack against the Z-Wave S0 Security version product by continuously sending divided "Nonce Get (0x98 0x81)" frames. The reason for dividing the "Nonce Get" frame is that, in security version S0, when a node receives a "Nonce Get" frame, the node produces a random new nonce and sends it to the Src node of the received "Nonce Get" frame. After the nonce value is generated and transmitted, the node transitions to wait mode. At this time, when "Nonce Get" is received again, the node discards the previous nonce value and generates a random nonce again. Therefore, because the frame is encrypted with previous nonce value, the received normal frame cannot be decrypted.
Aliases
Aliases
{
"GSD": {
"alias": "CVE-2018-19983",
"description": "An issue was discovered on Sigma Design Z-Wave S0 through S2 devices. An attacker first prepares a Z-Wave frame-transmission program (e.g., Z-Wave PC Controller, OpenZWave, CC1110, etc.). Next, the attacker conducts a DoS attack against the Z-Wave S0 Security version product by continuously sending divided \"Nonce Get (0x98 0x81)\" frames. The reason for dividing the \"Nonce Get\" frame is that, in security version S0, when a node receives a \"Nonce Get\" frame, the node produces a random new nonce and sends it to the Src node of the received \"Nonce Get\" frame. After the nonce value is generated and transmitted, the node transitions to wait mode. At this time, when \"Nonce Get\" is received again, the node discards the previous nonce value and generates a random nonce again. Therefore, because the frame is encrypted with previous nonce value, the received normal frame cannot be decrypted.",
"id": "GSD-2018-19983"
},
"gsd": {
"metadata": {
"exploitCode": "unknown",
"remediation": "unknown",
"reportConfidence": "confirmed",
"type": "vulnerability"
},
"osvSchema": {
"aliases": [
"CVE-2018-19983"
],
"details": "An issue was discovered on Sigma Design Z-Wave S0 through S2 devices. An attacker first prepares a Z-Wave frame-transmission program (e.g., Z-Wave PC Controller, OpenZWave, CC1110, etc.). Next, the attacker conducts a DoS attack against the Z-Wave S0 Security version product by continuously sending divided \"Nonce Get (0x98 0x81)\" frames. The reason for dividing the \"Nonce Get\" frame is that, in security version S0, when a node receives a \"Nonce Get\" frame, the node produces a random new nonce and sends it to the Src node of the received \"Nonce Get\" frame. After the nonce value is generated and transmitted, the node transitions to wait mode. At this time, when \"Nonce Get\" is received again, the node discards the previous nonce value and generates a random nonce again. Therefore, because the frame is encrypted with previous nonce value, the received normal frame cannot be decrypted.",
"id": "GSD-2018-19983",
"modified": "2023-12-13T01:22:38.946111Z",
"schema_version": "1.4.0"
}
},
"namespaces": {
"cve.org": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2018-19983",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "An issue was discovered on Sigma Design Z-Wave S0 through S2 devices. An attacker first prepares a Z-Wave frame-transmission program (e.g., Z-Wave PC Controller, OpenZWave, CC1110, etc.). Next, the attacker conducts a DoS attack against the Z-Wave S0 Security version product by continuously sending divided \"Nonce Get (0x98 0x81)\" frames. The reason for dividing the \"Nonce Get\" frame is that, in security version S0, when a node receives a \"Nonce Get\" frame, the node produces a random new nonce and sends it to the Src node of the received \"Nonce Get\" frame. After the nonce value is generated and transmitted, the node transitions to wait mode. At this time, when \"Nonce Get\" is received again, the node discards the previous nonce value and generates a random nonce again. Therefore, because the frame is encrypted with previous nonce value, the received normal frame cannot be decrypted."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://github.com/min1233/CVE/blob/master/2",
"refsource": "MISC",
"url": "https://github.com/min1233/CVE/blob/master/2"
}
]
}
},
"nvd.nist.gov": {
"configurations": {
"CVE_data_version": "4.0",
"nodes": [
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:silabs:z-wave_s0_firmware:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:silabs:z-wave_s0:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:silabs:z-wave_s2_firmware:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:silabs:z-wave_s2:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
}
]
},
"cve": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2018-19983"
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "en",
"value": "An issue was discovered on Sigma Design Z-Wave S0 through S2 devices. An attacker first prepares a Z-Wave frame-transmission program (e.g., Z-Wave PC Controller, OpenZWave, CC1110, etc.). Next, the attacker conducts a DoS attack against the Z-Wave S0 Security version product by continuously sending divided \"Nonce Get (0x98 0x81)\" frames. The reason for dividing the \"Nonce Get\" frame is that, in security version S0, when a node receives a \"Nonce Get\" frame, the node produces a random new nonce and sends it to the Src node of the received \"Nonce Get\" frame. After the nonce value is generated and transmitted, the node transitions to wait mode. At this time, when \"Nonce Get\" is received again, the node discards the previous nonce value and generates a random nonce again. Therefore, because the frame is encrypted with previous nonce value, the received normal frame cannot be decrypted."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "en",
"value": "CWE-330"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://github.com/min1233/CVE/blob/master/2",
"refsource": "MISC",
"tags": [
"Third Party Advisory"
],
"url": "https://github.com/min1233/CVE/blob/master/2"
}
]
}
},
"impact": {
"baseMetricV2": {
"acInsufInfo": false,
"cvssV2": {
"accessComplexity": "LOW",
"accessVector": "ADJACENT_NETWORK",
"authentication": "NONE",
"availabilityImpact": "COMPLETE",
"baseScore": 6.1,
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"vectorString": "AV:A/AC:L/Au:N/C:N/I:N/A:C",
"version": "2.0"
},
"exploitabilityScore": 6.5,
"impactScore": 6.9,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"severity": "MEDIUM",
"userInteractionRequired": false
},
"baseMetricV3": {
"cvssV3": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.0"
},
"exploitabilityScore": 2.8,
"impactScore": 3.6
}
},
"lastModifiedDate": "2019-10-03T00:03Z",
"publishedDate": "2018-12-09T19:29Z"
}
}
}
Loading…
Loading…
Experimental. This forecast is provided for visualization only and may change without notice. Do not use it for operational decisions.
Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.
Sightings
| Author | Source | Type | Date | Other |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…
Loading…