GHSA-6M6F-4VPP-RG9H

Vulnerability from github – Published: 2022-05-13 01:45 – Updated: 2022-05-13 01:45
VLAI?
Details

A vulnerability in the Stream Control Transmission Protocol (SCTP) decoder of the Cisco NetFlow Generation Appliance (NGA) with software before 1.1(1a) could allow an unauthenticated, remote attacker to cause the device to hang or unexpectedly reload, causing a denial of service (DoS) condition. The vulnerability is due to incomplete validation of SCTP packets being monitored on the NGA data ports. An attacker could exploit this vulnerability by sending malformed SCTP packets on a network that is monitored by an NGA data port. SCTP packets addressed to the IP address of the NGA itself will not trigger this vulnerability. An exploit could allow the attacker to cause the appliance to become unresponsive or reload, causing a DoS condition. User interaction could be needed to recover the device using the reboot command from the CLI. The following Cisco NetFlow Generation Appliances are vulnerable: NGA 3140, NGA 3240, NGA 3340. Cisco Bug IDs: CSCvc83320.

Show details on source website

{
  "affected": [],
  "aliases": [
    "CVE-2017-3826"
  ],
  "database_specific": {
    "cwe_ids": [
      "CWE-20"
    ],
    "github_reviewed": false,
    "github_reviewed_at": null,
    "nvd_published_at": "2017-03-01T21:59:00Z",
    "severity": "HIGH"
  },
  "details": "A vulnerability in the Stream Control Transmission Protocol (SCTP) decoder of the Cisco NetFlow Generation Appliance (NGA) with software before 1.1(1a) could allow an unauthenticated, remote attacker to cause the device to hang or unexpectedly reload, causing a denial of service (DoS) condition. The vulnerability is due to incomplete validation of SCTP packets being monitored on the NGA data ports. An attacker could exploit this vulnerability by sending malformed SCTP packets on a network that is monitored by an NGA data port. SCTP packets addressed to the IP address of the NGA itself will not trigger this vulnerability. An exploit could allow the attacker to cause the appliance to become unresponsive or reload, causing a DoS condition. User interaction could be needed to recover the device using the reboot command from the CLI. The following Cisco NetFlow Generation Appliances are vulnerable: NGA 3140, NGA 3240, NGA 3340. Cisco Bug IDs: CSCvc83320.",
  "id": "GHSA-6m6f-4vpp-rg9h",
  "modified": "2022-05-13T01:45:55Z",
  "published": "2022-05-13T01:45:55Z",
  "references": [
    {
      "type": "ADVISORY",
      "url": "https://nvd.nist.gov/vuln/detail/CVE-2017-3826"
    },
    {
      "type": "WEB",
      "url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-20170301-nga"
    },
    {
      "type": "WEB",
      "url": "http://www.securityfocus.com/bid/96509"
    },
    {
      "type": "WEB",
      "url": "http://www.securitytracker.com/id/1037938"
    }
  ],
  "schema_version": "1.4.0",
  "severity": [
    {
      "score": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
      "type": "CVSS_V3"
    }
  ]
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.


Loading…