GCVE-1988-2026-0528

Vulnerability from gna-1988 – Published: 2026-11-02 09:47 – Updated: 2026-11-02 09:47
VLAI
Title
[Bugtraq] Johnson Controls - DSC TL280 - home alarm system - Use of a Broken or Risky Cryptographic Algorithm
Summary
CVE-ID: CVE-2026-27871 Vendor of Product: Johnson Controls (formerly Tyco / DSC) Affected Product Code Base: TL280, 5.62.04.003 (latest) Affected Component: Communication with the Integration server Suggested description: The DSC Neo alarm system can interface with “integration servers” to notify about alarm events. These “integration servers” can also send arm/disarm events to the alarm system. The “Type 2” (ITv2) communication between the TL280 and “integration servers” uses AES in ECB mode. ECB mode is a weak, broken cryptography mode. It does not provide forward secrecy; there is no mutual authentication, and a single shared key is used to secure the communication. Only weak integrity protection (CRC) is provided in the protocol. Additional Information: During the initial setup, the fixed key 12345678123456781234567812345678 is used for the communication. Attack Type: Network CVSS 3.1 Base Score: 9.0 Critical Vector: CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:C/C:H/I:H/A:H Contributing Weakness: AES-ECB Mode (CWE-327) - this advisory Contributing Weakness: Default Cryptographic Key (CWE-1394) - 12345678123456781234567812345678 Combined Impact: An attacker who can observe the initial TL280 handshake (which uses a default key) can decrypt the negotiated AES session key. All subsequent panel<->cloud communications are then readable, including user disarm codes and installer access codes. The use of AES-ECB mode with no proper replay protection allows the attacker to replay previously captured disarm commands, silently changing the alarm state from armed to disarmed. The panel logs a sequence mismatch error but executes the command. Affected data includes: - User arm/disarm PIN codes - Installer programming codes - Motion sensor activation events (enabling occupancy profiling) - System configuration and zone status Physical security impact: Complete silent defeat of intrusion detection for homes and businesses protected by this system. Has the vendor confirmed or acknowledged the vulnerability? Yes. Reported via VulnCheck (CNA coordinator) on 2026-02-16. The Johnson Controls PSIRT confirmed receipt on 2026-02-27, assigned CVE-2026-27871 on 2026-03-24 with the title "DSC TL280 Internal Security Alarm - Use of Broken or Risky Cryptographic Algorithm", reproduced the issue, and committed to a patch by 2026-08-01. Vendor contact point: https://www.johnsoncontrols.com/trust-center/cybersecurity/resources#Contact... Vulnerability Type: Other CWE-327: Use of a Broken or Risky Cryptographic Algorithm Discoverer: z Reference: https://github.com/D-S-C-O-M-G-N-E-O/D-S-C-O-M-G-N-E-O/CVE-2026-27871.mdhttp... Disclosure timeline: Coordinated through VulnCheck (disclosure@vulncheck.com), with Johnson Controls PSIRT as the supplier CNA. Reporter credited as "z". - 2026-02-16 — Vulnerability reported to VulnCheck. - 2026-02-18 — VulnCheck confirms receipt; engages Johnson Controls (supplier CNA) for determination and CVE assignment. 120-day disclosure deadline set to 2026-06-18. Reporter shares the Wireshark dissector (decrypts panel↔cloud traffic given the static key and a captured session start) and notes the documented default setup key 12345678123456781234567812345678 plus a suspected key-exchange that would expose all future session keys. - 2026-02-19 — Reporter sends supporting references (OWASP WSTG, NIST SP 800-131A, Schneier) on why ECB is disallowed. - 2026-02-27 — Johnson Controls confirms receipt of the report. - 2026-03-24 — Johnson Controls PSIRT assigns CVE-2026-27871, title "DSC TL280 Internal Security Alarm - Use of Broken or Risky Cryptographic Algorithm"; CISA coordination draft in progress. - 2026-03-25 — Reporter shares PoC: (1) screenshot (tl280_AES_ECB.png) of the dissector decrypting initial TL280→cloud setup traffic, highlighting the server's 0x0632 (Change_Static_Keys) command — passive capture of the first session allows decryption of all future traffic, including user/installer codes; (2) screen recording demonstrating that a replayed disarm packet disarms the panel even without knowing any keys/codes, and despite the panel returning a sequence-number error. - 2026-04-23 — VulnCheck follows up with Johnson Controls (no update). - 2026-05-06 — Johnson Controls reports it is reproducing the issue; final fix tracking to ~September/October 2026; requests deadline extension. - 2026-05-14 — Johnson Controls provisionally allocates CVE-2026-27871 in its Trust Center case platform and proposes a 2026-08-31 deadline. - 2026-05-21 — Reporter agrees to an extension only to 2026-08-01. - 2026-06-02 — Johnson Controls PSIRT agrees to the 2026-08-01 deadline; states a patch is expected by 2026-08-01. - 2026-06-06 — Reporter acknowledges. - 2026-08-01 - This advisory published, no information on any patches from the vendor. - 2026-08-03 - 5.63 is allegedly published to fix these, could not download it, could not test it. Johnson Controls is silent, no communication from their side even though August 1 was an agreed date for disclosure. Bad CNA. PS: you might find some other goodies in the repo
Severity
No CVSS data available.
Assigner
VULNARCHIVE GNA GNA-1988
GNA scorecard E 38/100 over 581 records in the last 180 days details
Impacted products
Vendor Product Version CPE status
unknown Johnson Controls Affected: unknown
guessed Create a notification for this product.
Credits
z
Relationships
analysis GCVE-1988-2026-0528 (this record)

{
  "containers": {
    "cna": {
      "affected": [
        {
          "product": "Johnson Controls",
          "vendor": "unknown",
          "versions": [
            {
              "status": "affected",
              "version": "unknown"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "z"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "CVE-ID:\nCVE-2026-27871\nVendor of Product:\nJohnson Controls (formerly Tyco / DSC)\nAffected Product Code Base:\nTL280, 5.62.04.003 (latest)\nAffected Component:\nCommunication with the Integration server\nSuggested description:\nThe DSC Neo alarm system can interface with \u201cintegration servers\u201d to notify about alarm events. These \u201cintegration servers\u201d can also send arm/disarm events to the alarm system. The \u201cType 2\u201d (ITv2) communication between the TL280 and \u201cintegration servers\u201d uses AES in ECB mode.  ECB mode is a weak, broken cryptography mode. It does not provide forward secrecy; there is no mutual authentication, and a single shared key is used to secure the communication. Only weak integrity protection (CRC) is provided in the protocol.\nAdditional Information:\nDuring the initial setup, the fixed key 12345678123456781234567812345678 is used for the communication.\nAttack Type:\nNetwork\nCVSS 3.1 Base Score: 9.0 Critical\nVector: CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:C/C:H/I:H/A:H\nContributing Weakness: AES-ECB Mode (CWE-327) - this advisory\nContributing Weakness: Default Cryptographic Key (CWE-1394) - 12345678123456781234567812345678\nCombined Impact: An attacker who can observe the initial TL280\nhandshake (which uses a default key) can decrypt the negotiated\nAES session key. All subsequent panel\u003c-\u003ecloud communications are\nthen readable, including user disarm codes and installer access\ncodes. The use of AES-ECB mode with no proper replay protection allows\nthe attacker to replay previously captured disarm commands,\nsilently changing the alarm state from armed to disarmed. The\npanel logs a sequence mismatch error but executes the command.\nAffected data includes:\n- User arm/disarm PIN codes\n- Installer programming codes\n- Motion sensor activation events (enabling occupancy profiling)\n- System configuration and zone status\nPhysical security impact: Complete silent defeat of intrusion\ndetection for homes and businesses protected by this system.\nHas the vendor confirmed or acknowledged the vulnerability?\nYes. Reported via VulnCheck (CNA coordinator) on 2026-02-16. The Johnson Controls PSIRT confirmed receipt on 2026-02-27, assigned CVE-2026-27871 on 2026-03-24 with the title \"DSC TL280 Internal Security Alarm - Use of Broken or Risky Cryptographic Algorithm\", reproduced the issue, and committed to a patch by 2026-08-01.\nVendor contact point: https://www.johnsoncontrols.com/trust-center/cybersecurity/resources#Contact...\nVulnerability Type:\nOther\nCWE-327: Use of a Broken or Risky Cryptographic Algorithm\nDiscoverer:\nz\nReference:\nhttps://github.com/D-S-C-O-M-G-N-E-O/D-S-C-O-M-G-N-E-O/CVE-2026-27871.mdhttp...\nDisclosure timeline:\nCoordinated through VulnCheck (disclosure@vulncheck.com), with Johnson Controls PSIRT as the supplier CNA. Reporter credited as \"z\".\n- 2026-02-16 \u2014 Vulnerability reported to VulnCheck.\n- 2026-02-18 \u2014 VulnCheck confirms receipt; engages Johnson Controls (supplier CNA) for determination and CVE assignment. 120-day disclosure deadline set to 2026-06-18. Reporter shares the Wireshark dissector (decrypts panel\u2194cloud traffic given the static key and a captured session start) and notes the documented default setup key 12345678123456781234567812345678 plus a suspected key-exchange that would expose all future session keys.\n- 2026-02-19 \u2014 Reporter sends supporting references (OWASP WSTG, NIST SP 800-131A, Schneier) on why ECB is disallowed.\n- 2026-02-27 \u2014 Johnson Controls confirms receipt of the report.\n- 2026-03-24 \u2014 Johnson Controls PSIRT assigns CVE-2026-27871, title \"DSC TL280 Internal Security Alarm - Use of Broken or Risky Cryptographic Algorithm\"; CISA coordination draft in progress.\n- 2026-03-25 \u2014 Reporter shares PoC: (1) screenshot (tl280_AES_ECB.png) of the dissector decrypting initial TL280\u2192cloud setup traffic, highlighting the server\u0027s 0x0632 (Change_Static_Keys) command \u2014 passive capture of the first session allows decryption of all future traffic, including user/installer codes; (2) screen recording demonstrating that a replayed disarm packet disarms the panel even without knowing any keys/codes, and despite the panel returning a sequence-number error.\n- 2026-04-23 \u2014 VulnCheck follows up with Johnson Controls (no update).\n- 2026-05-06 \u2014 Johnson Controls reports it is reproducing the issue; final fix tracking to ~September/October 2026; requests deadline extension.\n- 2026-05-14 \u2014 Johnson Controls provisionally allocates CVE-2026-27871 in its Trust Center case platform and proposes a 2026-08-31 deadline.\n- 2026-05-21 \u2014 Reporter agrees to an extension only to 2026-08-01.\n- 2026-06-02 \u2014 Johnson Controls PSIRT agrees to the 2026-08-01 deadline; states a patch is expected by 2026-08-01.\n- 2026-06-06 \u2014 Reporter acknowledges.\n- 2026-08-01 - This advisory published, no information on any patches from the vendor.\n- 2026-08-03 - 5.63 is allegedly published to fix these, could not download it, could not test it. Johnson Controls is silent, no communication from their side even though August 1 was an agreed date for disclosure. Bad CNA.\nPS: you might find some other goodies in the repo"
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-1394",
              "description": "CWE-1394",
              "lang": "en",
              "type": "CWE"
            },
            {
              "cweId": "CWE-327",
              "description": "CWE-327",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-11-02T09:47:22Z",
        "orgId": "4e2abfbf-4a2a-4b76-a4e0-d77c18ba156c",
        "shortName": "VULNARCHIVE"
      },
      "references": [
        {
          "tags": [
            "technical-description",
            "exploit"
          ],
          "url": "https://vuln.freearchive.org/archive/item/8956114097a68fb12b88e89a439aa37c04dfccc16feb40d9e456fc161e360705"
        },
        {
          "tags": [
            "technical-description"
          ],
          "url": "https://lists.securityfocus.com/hyperkitty/list/bugtraq@securityfocus.com/message/3AA4HBZRWRD3D237X7FFSUM4LUCWPMOM/"
        },
        {
          "url": "https://github.com/D-S-C-O-M-G-N-E-O/D-S-C-O-M-G-N-E-O/CVE-2026-27871.mdhttp://dsc.com"
        },
        {
          "url": "https://www.johnsoncontrols.com/trust-center/cybersecurity/resources#ContactUs"
        }
      ],
      "source": {
        "defect": [
          "OzGxtx_--F-9%40tutanota.com"
        ],
        "discovery": "EXTERNAL"
      },
      "title": "[Bugtraq] Johnson Controls - DSC TL280 - home alarm system - Use of a Broken or Risky Cryptographic Algorithm",
      "x_gcve": [
        {
          "recordType": "analysis",
          "relationships": [
            {
              "destId": "CVE-2026-27871",
              "type": "related"
            }
          ],
          "vulnId": "GCVE-1988-2026-0528",
          "x_vulnarchive": {
            "archiveUrl": "https://vuln.freearchive.org/archive/item/8956114097a68fb12b88e89a439aa37c04dfccc16feb40d9e456fc161e360705",
            "automated": true,
            "contentSha256": "8956114097a68fb12b88e89a439aa37c04dfccc16feb40d9e456fc161e360705",
            "evidenceScore": 11,
            "messageId": "OzGxtx_--F-9%40tutanota.com",
            "originalUrl": "https://lists.securityfocus.com/hyperkitty/list/bugtraq@securityfocus.com/message/3AA4HBZRWRD3D237X7FFSUM4LUCWPMOM/",
            "policy": "vulnarchive-1",
            "sourceFormat": "text/html",
            "sourcePublishedAt": "2026-11-02T09:47:22Z"
          }
        },
        {
          "recordType": "advisory",
          "vulnId": "gcve-1988-2026-0528"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "4e2abfbf-4a2a-4b76-a4e0-d77c18ba156c",
    "assignerShortName": "VULNARCHIVE",
    "datePublished": "2026-11-02T09:47:22Z",
    "dateUpdated": "2026-11-02T09:47:22Z",
    "state": "PUBLISHED",
    "vulnId": "GCVE-1988-2026-0528"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}



Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Drag nodes to arrange them. Double-click a related vulnerability to open it, or a source to visit its link. The Physics button on the left tunes the layout and the simulation; the legend at the bottom left hides or shows nodes by kind and by sighting type.

Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.

Sightings

Author Source Type Date Other

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Vulnerability timeline

Sightings and recorded dates, grouped by day · UTC

JSON
How durations are calculated

Following the VTEM framework (Black Hat USA 2015), time to patch starts when the vendor or a coordinator was informed, total time to patch at discovery, and disclosure to patch at public disclosure; vendor response time runs from the report to its acknowledgement. Time to exploit and time unpatched start at the earliest discovery or report, falling back to public disclosure. Unpatched time ends at the first recorded patch, or the calculation time when no patch is recorded. Exploitation to patch shows the interval between those two events; a published proof of concept is a public exploit, not exploitation.

Each result shows its source dates. A negative interval means the end event came first; when date-only inputs leave the order open, the result says so. Date-only inputs are approximate. The earliest evidence wins: KEV report dates and sightings are labelled as such. Records describing another vulnerability are listed but never calculated from, and a PoC alone does not establish exploitation. Missing patch evidence does not prove that no patch exists. Filters below change the event list only.

Events included in the timeline

Loading timeline…


    Loading…

    Loading…

    Loading…

    Related by attack behaviour