FKIE_CVE-2026-27758

Vulnerability from fkie_nvd - Published: 2026-02-27 19:16 - Updated: 2026-03-03 19:08
Summary
SODOLA SL902-SWTGW124AS firmware versions through 200.1.20 contain a cross-site request forgery vulnerability in its management interface that allows attackers to induce authenticated users into submitting forged requests. Attackers can craft malicious requests that execute unauthorized configuration or administrative actions with the victim's privileges when the authenticated user visits a malicious webpage.
Impacted products

{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:sodola-network:sl902-swtgw124as_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "18BBB9A4-A6EC-45DD-955C-2070C0098E91",
              "versionEndIncluding": "200.1.20",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:sodola-network:sl902-swtgw124as:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "542ED775-5070-40DA-88A5-6FA98075BAD5",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "SODOLA SL902-SWTGW124AS firmware versions through 200.1.20 contain a cross-site request forgery vulnerability in its management interface that allows attackers to induce authenticated users into submitting forged requests. Attackers can craft malicious requests that execute unauthorized configuration or administrative actions with the victim\u0027s privileges when the authenticated user visits a malicious webpage."
    },
    {
      "lang": "es",
      "value": "Las versiones de firmware de SODOLA SL902-SWTGW124AS hasta la 200.1.20 contienen una vulnerabilidad de falsificaci\u00f3n de petici\u00f3n en sitios cruzados en su interfaz de gesti\u00f3n que permite a los atacantes inducir a usuarios autenticados a enviar peticiones falsificadas. Los atacantes pueden elaborar peticiones maliciosas que ejecutan acciones de configuraci\u00f3n o administraci\u00f3n no autorizadas con los privilegios de la v\u00edctima cuando el usuario autenticado visita una p\u00e1gina web maliciosa."
    }
  ],
  "id": "CVE-2026-27758",
  "lastModified": "2026-03-03T19:08:51.550",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "NONE",
          "baseScore": 4.3,
          "baseSeverity": "MEDIUM",
          "confidentialityImpact": "NONE",
          "integrityImpact": "LOW",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "REQUIRED",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:L/A:N",
          "version": "3.1"
        },
        "exploitabilityScore": 2.8,
        "impactScore": 1.4,
        "source": "disclosure@vulncheck.com",
        "type": "Secondary"
      },
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "NONE",
          "baseScore": 6.5,
          "baseSeverity": "MEDIUM",
          "confidentialityImpact": "NONE",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "REQUIRED",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:H/A:N",
          "version": "3.1"
        },
        "exploitabilityScore": 2.8,
        "impactScore": 3.6,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ],
    "cvssMetricV40": [
      {
        "cvssData": {
          "Automatable": "NOT_DEFINED",
          "Recovery": "NOT_DEFINED",
          "Safety": "NOT_DEFINED",
          "attackComplexity": "LOW",
          "attackRequirements": "NONE",
          "attackVector": "NETWORK",
          "availabilityRequirement": "NOT_DEFINED",
          "baseScore": 5.1,
          "baseSeverity": "MEDIUM",
          "confidentialityRequirement": "NOT_DEFINED",
          "exploitMaturity": "NOT_DEFINED",
          "integrityRequirement": "NOT_DEFINED",
          "modifiedAttackComplexity": "NOT_DEFINED",
          "modifiedAttackRequirements": "NOT_DEFINED",
          "modifiedAttackVector": "NOT_DEFINED",
          "modifiedPrivilegesRequired": "NOT_DEFINED",
          "modifiedSubAvailabilityImpact": "NOT_DEFINED",
          "modifiedSubConfidentialityImpact": "NOT_DEFINED",
          "modifiedSubIntegrityImpact": "NOT_DEFINED",
          "modifiedUserInteraction": "NOT_DEFINED",
          "modifiedVulnAvailabilityImpact": "NOT_DEFINED",
          "modifiedVulnConfidentialityImpact": "NOT_DEFINED",
          "modifiedVulnIntegrityImpact": "NOT_DEFINED",
          "privilegesRequired": "NONE",
          "providerUrgency": "NOT_DEFINED",
          "subAvailabilityImpact": "NONE",
          "subConfidentialityImpact": "NONE",
          "subIntegrityImpact": "NONE",
          "userInteraction": "ACTIVE",
          "valueDensity": "NOT_DEFINED",
          "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:A/VC:N/VI:L/VA:N/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
          "version": "4.0",
          "vulnAvailabilityImpact": "NONE",
          "vulnConfidentialityImpact": "NONE",
          "vulnIntegrityImpact": "LOW",
          "vulnerabilityResponseEffort": "NOT_DEFINED"
        },
        "source": "disclosure@vulncheck.com",
        "type": "Secondary"
      }
    ]
  },
  "published": "2026-02-27T19:16:10.183",
  "references": [
    {
      "source": "disclosure@vulncheck.com",
      "tags": [
        "Product"
      ],
      "url": "https://www.sodola-network.com/products/sodola-6-port-2-5g-easy-web-managed-switch-4-x-2-5g-base-t-ports-2-x-10g-sfp-static-aggregation-qos-vlan-igmp-2-5gb-network-home-lab-switch"
    },
    {
      "source": "disclosure@vulncheck.com",
      "tags": [
        "Third Party Advisory"
      ],
      "url": "https://www.vulncheck.com/advisories/sodola-sl902-swtgw124as-missing-csrf-protections"
    }
  ],
  "sourceIdentifier": "disclosure@vulncheck.com",
  "vulnStatus": "Analyzed",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-352"
        }
      ],
      "source": "disclosure@vulncheck.com",
      "type": "Primary"
    }
  ]
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.


Loading…

Detection rules are retrieved from Rulezet.

Loading…

Loading…