FKIE_CVE-2026-24440
Vulnerability from fkie_nvd - Published: 2026-01-26 18:16 - Updated: 2026-01-28 19:20
Severity ?
Summary
Shenzhen Tenda W30E V2 firmware versions up to and including V16.01.0.19(5037) allow account passwords to be changed through the maintenance interface without requiring verification of the existing password. This enables unauthorized password changes when access to the affected endpoint is obtained.
References
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| tenda | w30e_firmware | * | |
| tenda | w30e | 2.0 |
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:tenda:w30e_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "4DB07B19-71FC-4936-98BD-36A8B3B7CBF0",
"versionEndIncluding": "16.01.0.19\\(5037\\)",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:tenda:w30e:2.0:*:*:*:*:*:*:*",
"matchCriteriaId": "56B9C2BB-D36E-40F8-83FF-FC919337F6BD",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "Shenzhen Tenda W30E V2 firmware versions up to and including V16.01.0.19(5037) allow account passwords to be changed through the maintenance interface without requiring verification of the existing password. This enables unauthorized password changes when access to the affected endpoint is obtained."
},
{
"lang": "es",
"value": "Las versiones de firmware de Shenzhen Tenda W30E V2 hasta e incluyendo V16.01.0.19(5037) permiten cambiar las contrase\u00f1as de cuenta a trav\u00e9s de la interfaz de mantenimiento sin requerir verificaci\u00f3n de la contrase\u00f1a existente. Esto posibilita cambios de contrase\u00f1a no autorizados cuando se obtiene acceso al endpoint afectado."
}
],
"id": "CVE-2026-24440",
"lastModified": "2026-01-28T19:20:05.660",
"metrics": {
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 2.8,
"impactScore": 5.9,
"source": "nvd@nist.gov",
"type": "Primary"
}
],
"cvssMetricV40": [
{
"cvssData": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "NETWORK",
"availabilityRequirement": "NOT_DEFINED",
"baseScore": 8.7,
"baseSeverity": "HIGH",
"confidentialityRequirement": "NOT_DEFINED",
"exploitMaturity": "NOT_DEFINED",
"integrityRequirement": "NOT_DEFINED",
"modifiedAttackComplexity": "NOT_DEFINED",
"modifiedAttackRequirements": "NOT_DEFINED",
"modifiedAttackVector": "NOT_DEFINED",
"modifiedPrivilegesRequired": "NOT_DEFINED",
"modifiedSubAvailabilityImpact": "NOT_DEFINED",
"modifiedSubConfidentialityImpact": "NOT_DEFINED",
"modifiedSubIntegrityImpact": "NOT_DEFINED",
"modifiedUserInteraction": "NOT_DEFINED",
"modifiedVulnAvailabilityImpact": "NOT_DEFINED",
"modifiedVulnConfidentialityImpact": "NOT_DEFINED",
"modifiedVulnIntegrityImpact": "NOT_DEFINED",
"privilegesRequired": "LOW",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"source": "disclosure@vulncheck.com",
"type": "Secondary"
}
]
},
"published": "2026-01-26T18:16:41.637",
"references": [
{
"source": "disclosure@vulncheck.com",
"tags": [
"Product"
],
"url": "https://www.tendacn.com/product/W30E"
},
{
"source": "disclosure@vulncheck.com",
"tags": [
"Third Party Advisory"
],
"url": "https://www.vulncheck.com/advisories/tenda-w30e-v2-allows-password-change-without-verifying-current-password"
}
],
"sourceIdentifier": "disclosure@vulncheck.com",
"vulnStatus": "Analyzed",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-620"
}
],
"source": "disclosure@vulncheck.com",
"type": "Primary"
}
]
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…
Loading…