FKIE_CVE-2026-23755
Vulnerability from fkie_nvd - Published: 2026-01-21 18:16 - Updated: 2026-01-30 21:33
Severity ?
Summary
D-Link D-View 8 versions 2.0.1.107 and below contain an uncontrolled search path vulnerability in the installer. When executed with elevated privileges via UAC, the installer attempts to load version.dll from its execution directory, allowing DLL preloading. An attacker can supply a malicious version.dll alongside the legitimate installer so that, when a victim runs the installer and approves the UAC prompt, attacker-controlled code executes with administrator privileges. This can lead to full system compromise.
References
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:dlink:d-view_8:*:*:*:*:*:*:*:*",
"matchCriteriaId": "E503B0B7-ED8A-42E4-8519-732D4AE9C796",
"versionEndIncluding": "2.0.1.107",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "D-Link D-View 8 versions 2.0.1.107 and below contain an uncontrolled search path vulnerability in the installer. When executed with elevated privileges via UAC, the installer attempts to load version.dll from its execution directory, allowing DLL preloading. An attacker can supply a malicious version.dll alongside the legitimate installer so that, when a victim runs the installer and approves the UAC prompt, attacker-controlled code executes with administrator privileges. This can lead to full system compromise."
},
{
"lang": "es",
"value": "Versiones 2.0.1.107 y anteriores de D-Link D-View 8 contienen una vulnerabilidad de ruta de b\u00fasqueda no controlada en el instalador. Cuando se ejecuta con privilegios elevados a trav\u00e9s de UAC, el instalador intenta cargar version.dll desde su directorio de ejecuci\u00f3n, permitiendo la precarga de DLL. Un atacante puede suministrar un version.dll malicioso junto con el instalador leg\u00edtimo de modo que, cuando una v\u00edctima ejecuta el instalador y aprueba la solicitud de UAC, el c\u00f3digo controlado por el atacante se ejecuta con privilegios de administrador. Esto puede conducir a un compromiso total del sistema."
}
],
"id": "CVE-2026-23755",
"lastModified": "2026-01-30T21:33:18.047",
"metrics": {
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.3,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 1.3,
"impactScore": 5.9,
"source": "nvd@nist.gov",
"type": "Primary"
}
],
"cvssMetricV40": [
{
"cvssData": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "LOCAL",
"availabilityRequirement": "NOT_DEFINED",
"baseScore": 8.4,
"baseSeverity": "HIGH",
"confidentialityRequirement": "NOT_DEFINED",
"exploitMaturity": "NOT_DEFINED",
"integrityRequirement": "NOT_DEFINED",
"modifiedAttackComplexity": "NOT_DEFINED",
"modifiedAttackRequirements": "NOT_DEFINED",
"modifiedAttackVector": "NOT_DEFINED",
"modifiedPrivilegesRequired": "NOT_DEFINED",
"modifiedSubAvailabilityImpact": "NOT_DEFINED",
"modifiedSubConfidentialityImpact": "NOT_DEFINED",
"modifiedSubIntegrityImpact": "NOT_DEFINED",
"modifiedUserInteraction": "NOT_DEFINED",
"modifiedVulnAvailabilityImpact": "NOT_DEFINED",
"modifiedVulnConfidentialityImpact": "NOT_DEFINED",
"modifiedVulnIntegrityImpact": "NOT_DEFINED",
"privilegesRequired": "NONE",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "ACTIVE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:A/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"source": "disclosure@vulncheck.com",
"type": "Secondary"
}
]
},
"published": "2026-01-21T18:16:26.117",
"references": [
{
"source": "disclosure@vulncheck.com",
"tags": [
"Vendor Advisory",
"Patch"
],
"url": "https://supportannouncement.us.dlink.com/security/publication.aspx?name=SAP10471"
},
{
"source": "disclosure@vulncheck.com",
"tags": [
"Third Party Advisory"
],
"url": "https://www.vulncheck.com/advisories/dlink-dview-8-installer-dll-preloading-via-uncontrolled-search-path"
}
],
"sourceIdentifier": "disclosure@vulncheck.com",
"vulnStatus": "Analyzed",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-427"
}
],
"source": "disclosure@vulncheck.com",
"type": "Primary"
}
]
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…
Loading…