FKIE_CVE-2026-22268
Vulnerability from fkie_nvd - Published: 2026-02-19 10:16 - Updated: 2026-02-20 16:12
Severity ?
6.3 (Medium) - CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:U/C:N/I:L/A:H
6.5 (Medium) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H
6.5 (Medium) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H
Summary
Dell PowerProtect Data Manager, version(s) prior to 19.22, contain(s) an Incorrect Privilege Assignment vulnerability. A low privileged attacker with remote access could potentially exploit this vulnerability, leading to denial of service of a Dell Enterprise Support connection.
References
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| dell | powerprotect_data_manager | * |
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:dell:powerprotect_data_manager:*:*:*:*:*:*:*:*",
"matchCriteriaId": "17D7AA01-F2D1-4DCF-BF83-0550AA9CC59A",
"versionEndExcluding": "19.22",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "Dell PowerProtect Data Manager, version(s) prior to 19.22, contain(s) an Incorrect Privilege Assignment vulnerability. A low privileged attacker with remote access could potentially exploit this vulnerability, leading to denial of service of a Dell Enterprise Support connection."
}
],
"id": "CVE-2026-22268",
"lastModified": "2026-02-20T16:12:18.710",
"metrics": {
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 6.3,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "LOW",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:U/C:N/I:L/A:H",
"version": "3.1"
},
"exploitabilityScore": 2.1,
"impactScore": 4.2,
"source": "security_alert@emc.com",
"type": "Secondary"
},
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"exploitabilityScore": 2.8,
"impactScore": 3.6,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2026-02-19T10:16:11.963",
"references": [
{
"source": "security_alert@emc.com",
"tags": [
"Vendor Advisory"
],
"url": "https://www.dell.com/support/kbdoc/en-us/000429778/dsa-2026-046-security-update-for-dell-powerprotect-data-manager-multiple-vulnerabilities"
}
],
"sourceIdentifier": "security_alert@emc.com",
"vulnStatus": "Analyzed",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-266"
}
],
"source": "security_alert@emc.com",
"type": "Primary"
}
]
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…
Loading…