FKIE_CVE-2026-22192

Vulnerability from fkie_nvd - Published: 2026-03-13 19:54 - Updated: 2026-04-22 19:17
Summary
Voltronic Power SNMP Web Pro version 1.1 contains an authentication bypass vulnerability that allows unauthenticated attackers to access privileged management functions by manipulating browser localStorage values. Attackers can modify client-side authentication state to bypass server-side access controls and gain unauthorized access to protected management functionality without valid credentials.
Impacted products
Vendor Product Version
gvectors wpdiscuz *

{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:gvectors:wpdiscuz:*:*:*:*:*:wordpress:*:*",
              "matchCriteriaId": "A81F51B9-0C21-4F7E-876B-C09A66B9AE05",
              "versionEndExcluding": "7.6.47",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "Voltronic Power SNMP Web Pro version 1.1 contains an authentication bypass vulnerability that allows unauthenticated attackers to access privileged management functions by manipulating browser localStorage values. Attackers can modify client-side authentication state to bypass server-side access controls and gain unauthorized access to protected management functionality without valid credentials."
    },
    {
      "lang": "es",
      "value": "wpDiscuz anterior a la versi\u00f3n 7.6.47 contiene una vulnerabilidad de cross-site scripting almacenada que permite a atacantes autenticados inyectar JavaScript malicioso importando un archivo de opciones manipulado con valores de campo customCss sin escapar. Los atacantes pueden proporcionar un archivo de importaci\u00f3n JSON malicioso que contiene cargas \u00fatiles de script en el par\u00e1metro customCss que se ejecutan en cada p\u00e1gina cuando se renderizan a trav\u00e9s del gestor de opciones sin una sanitizaci\u00f3n adecuada."
    }
  ],
  "id": "CVE-2026-22192",
  "lastModified": "2026-04-22T19:17:00.303",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "LOW",
          "baseScore": 9.9,
          "baseSeverity": "CRITICAL",
          "confidentialityImpact": "LOW",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "CHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:L/I:H/A:L",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 5.3,
        "source": "disclosure@vulncheck.com",
        "type": "Primary"
      },
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "NONE",
          "baseScore": 5.4,
          "baseSeverity": "MEDIUM",
          "confidentialityImpact": "LOW",
          "integrityImpact": "LOW",
          "privilegesRequired": "LOW",
          "scope": "CHANGED",
          "userInteraction": "REQUIRED",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:C/C:L/I:L/A:N",
          "version": "3.1"
        },
        "exploitabilityScore": 2.3,
        "impactScore": 2.7,
        "source": "nvd@nist.gov",
        "type": "Secondary"
      }
    ],
    "cvssMetricV40": [
      {
        "cvssData": {
          "Automatable": "NOT_DEFINED",
          "Recovery": "NOT_DEFINED",
          "Safety": "NOT_DEFINED",
          "attackComplexity": "LOW",
          "attackRequirements": "NONE",
          "attackVector": "NETWORK",
          "availabilityRequirement": "NOT_DEFINED",
          "baseScore": 8.8,
          "baseSeverity": "HIGH",
          "confidentialityRequirement": "NOT_DEFINED",
          "exploitMaturity": "NOT_DEFINED",
          "integrityRequirement": "NOT_DEFINED",
          "modifiedAttackComplexity": "NOT_DEFINED",
          "modifiedAttackRequirements": "NOT_DEFINED",
          "modifiedAttackVector": "NOT_DEFINED",
          "modifiedPrivilegesRequired": "NOT_DEFINED",
          "modifiedSubAvailabilityImpact": "NOT_DEFINED",
          "modifiedSubConfidentialityImpact": "NOT_DEFINED",
          "modifiedSubIntegrityImpact": "NOT_DEFINED",
          "modifiedUserInteraction": "NOT_DEFINED",
          "modifiedVulnAvailabilityImpact": "NOT_DEFINED",
          "modifiedVulnConfidentialityImpact": "NOT_DEFINED",
          "modifiedVulnIntegrityImpact": "NOT_DEFINED",
          "privilegesRequired": "NONE",
          "providerUrgency": "NOT_DEFINED",
          "subAvailabilityImpact": "NONE",
          "subConfidentialityImpact": "NONE",
          "subIntegrityImpact": "NONE",
          "userInteraction": "NONE",
          "valueDensity": "NOT_DEFINED",
          "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:L/VI:H/VA:L/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
          "version": "4.0",
          "vulnAvailabilityImpact": "LOW",
          "vulnConfidentialityImpact": "LOW",
          "vulnIntegrityImpact": "HIGH",
          "vulnerabilityResponseEffort": "NOT_DEFINED"
        },
        "source": "disclosure@vulncheck.com",
        "type": "Secondary"
      }
    ]
  },
  "published": "2026-03-13T19:54:09.507",
  "references": [
    {
      "source": "disclosure@vulncheck.com",
      "url": "https://github.com/kmkz/Exploits/blob/master/2026/CVE-2026-22192-22199_Voltronic-Power_Preauth_root_RCE.txt"
    },
    {
      "source": "disclosure@vulncheck.com",
      "url": "https://voltronicpower.com/"
    },
    {
      "source": "disclosure@vulncheck.com",
      "url": "https://www.boffsec-services.com/posts/sicuroweb-cve-2026-22191/"
    },
    {
      "source": "disclosure@vulncheck.com",
      "url": "https://www.vulncheck.com/advisories/voltronic-power-snmp-web-pro-authentication-bypass-via-localstorage"
    }
  ],
  "sourceIdentifier": "disclosure@vulncheck.com",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-306"
        }
      ],
      "source": "disclosure@vulncheck.com",
      "type": "Primary"
    }
  ]
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…
Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.

Sightings

Author Source Type Date Other

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.


Loading…

Detection rules are retrieved from Rulezet.

Loading…

Loading…