FKIE_CVE-2026-19683
Vulnerability from fkie_nvd - Published: 2026-08-20 19:16 - Updated: 2026-10-26 10:10{
"affected": [
{
"affectedData": [
{
"defaultStatus": "unaffected",
"product": "ER7212PC v2",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "2.4.3 Build 20260722 Rel.40250",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "ER605 v2",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "2.4.4 Build 20260630 Rel.14398",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "ER7206 v2",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "2.3.5 Build 20260625 Rel.43136",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "ER7406 v1",
"vendor": "TP-Link Systems Inc",
"versions": [
{
"lessThan": "1.3.4 Build 20260625 Rel.43136",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "ER707-M2 v1",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "1.4.4 Build 20260625 Rel.43063",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "ER7412-M2 v1",
"vendor": "TP-Link Systems Inc",
"versions": [
{
"lessThan": "1.2.0 Build 20260630 Rel.82947",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "ER8411 v1",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "1.4.1 Build 20260708 Rel.64832",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "ER706W v1",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "1.2.11 Build 20260723 Rel.41567",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "v1",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "1.2.6 Build 20260723 Rel.41321",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "ER706W-4G v2",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "2.1.11 Build 20260723 Rel.41624",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "ER706WP-4G v1",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "1.1.11 Build 20260723 Rel.41624",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "ER703WP-4G-Outdoor v1",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "1.1.7 Build 20260723 Rel.41712",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "DR3220v-4G v1",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "1.2.0 Build 20260630 Rel.82652",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "DR3650v v1",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "1.2.0 Build 20260630 Rel.83311",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "DR3650v-4G v1",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "1.2.0 Build 20260630 Rel.83347",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "ER603WP-4G-Outdoor v1",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "1.0.2 Build 20260723 Rel.43271",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "DR3150 v1",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "1.0.1 Build 20260722 Rel.16854",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "ER701-5G-Outdoor v1",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "1.0.3 Build 20260723 Rel.40931",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "ER605W v2",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "2.0.4 Build 20260723 Rel.43763",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"source": "f23511db-6c3e-4e32-a477-6aa17d310630"
}
],
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:tp-link:er7212pc_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "7D4F7E2D-BC8F-473D-938B-8E907538FB84",
"versionEndExcluding": "2.4.3",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:tp-link:er7212pc:2.0:*:*:*:*:*:*:*",
"matchCriteriaId": "939EE8A4-1CA6-495C-83B0-369B4367A402",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:tp-link:er605_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "D7DE29DB-20CA-4C32-A050-22C0C208683D",
"versionEndExcluding": "2.4.4",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:tp-link:er605:2.0:*:*:*:*:*:*:*",
"matchCriteriaId": "11B180B7-7FE9-4971-9F1A-9FD2A73FA9C3",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:tp-link:er7206_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "9FEBEB59-E7F4-45CE-A4FF-01169FB6D7A4",
"versionEndExcluding": "2.3.5",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:tp-link:er7206:2.0:*:*:*:*:*:*:*",
"matchCriteriaId": "4B8866B3-837C-47E0-94DD-CE771083CCD6",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:tp-link:er7406_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "36C3A9CA-B374-4B30-8647-867DCBDA888F",
"versionEndExcluding": "1.3.4",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:tp-link:er7406:-:*:*:*:*:*:*:*",
"matchCriteriaId": "3064CDE7-9329-4D22-8853-B4EE6D050D4B",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:tp-link:er707-m2_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "5C8E5FC5-FB02-4884-8561-16462A7FB015",
"versionEndExcluding": "1.4.4",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:tp-link:er707-m2:-:*:*:*:*:*:*:*",
"matchCriteriaId": "E45AF81F-1346-4FD8-9E38-CAB330D79AB6",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:tp-link:er7412-m2_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "52DFB291-70BB-49C1-B50F-E084CDCE56D6",
"versionEndExcluding": "1.2.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:tp-link:er7412-m2:-:*:*:*:*:*:*:*",
"matchCriteriaId": "FBB89DAE-6264-4F26-B34A-E1B84FB927D4",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:tp-link:er8411_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "14F8B834-3A2F-4B8B-BF3C-4C915F9C91B2",
"versionEndExcluding": "1.4.1",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:tp-link:er8411:-:*:*:*:*:*:*:*",
"matchCriteriaId": "4F2F16D8-5D7B-4E01-8BB3-F324B6011F72",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:tp-link:er706w_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "1DC2E6EB-47E1-4B3F-AE07-6E9C1120885E",
"versionEndExcluding": "1.2.11",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:tp-link:er706w:-:*:*:*:*:*:*:*",
"matchCriteriaId": "7D599C4B-4A58-45EC-BA17-332FBF6E9805",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:tp-link:er706w-4g_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "41F765B0-E24B-4EED-AC37-B54638DFBD3F",
"versionEndExcluding": "1.2.6",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:tp-link:er706w-4g:-:*:*:*:*:*:*:*",
"matchCriteriaId": "559FA8D2-3055-41CB-81A4-A7996D93588D",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:tp-link:er706w-4g_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "2C596A89-C9E9-4F8E-BD9F-6B807E3D568E",
"versionEndExcluding": "2.1.11",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:tp-link:er706w-4g:2.0:*:*:*:*:*:*:*",
"matchCriteriaId": "DE1504A8-4FDC-44E0-9C97-2AC838DC4FBF",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:tp-link:er706wp-4g_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "8886DEC9-65FE-4D88-B829-7082B7F27B8E",
"versionEndExcluding": "1.1.11",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:tp-link:er706wp-4g:-:*:*:*:*:*:*:*",
"matchCriteriaId": "CDF76B4C-3657-4C55-AC76-A31FC5A988A8",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:tp-link:er703wp-4g-outdoor_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "FFB8FCED-5F12-4631-857F-6F713558CA67",
"versionEndExcluding": "1.1.7",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:tp-link:er703wp-4g-outdoor:-:*:*:*:*:*:*:*",
"matchCriteriaId": "9984C375-4F11-4C3A-AB3D-9A23C4B9EE77",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:tp-link:dr3220v-4g_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "8F715148-236F-4EA0-9389-39AC93E3217C",
"versionEndExcluding": "1.2.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:tp-link:dr3220v-4g:-:*:*:*:*:*:*:*",
"matchCriteriaId": "CAA74D58-481A-40B3-BEC7-AD1782802C51",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:tp-link:dr3650v_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "16677C43-4338-4444-BBA6-C3A05AF167E5",
"versionEndExcluding": "1.2.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:tp-link:dr3650v:-:*:*:*:*:*:*:*",
"matchCriteriaId": "CD34FB5F-D4EA-41E3-B625-78A8045AC916",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:tp-link:dr3650v-4g_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "178A4ACF-15AB-4BAD-8EE9-1AB660220489",
"versionEndExcluding": "1.2.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:tp-link:dr3650v-4g:-:*:*:*:*:*:*:*",
"matchCriteriaId": "121CBA17-EB12-4611-B05B-A39C8DE06410",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:tp-link:er603wp-4g-outdoor_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "C516C8C6-29EB-4614-B8B3-C1D15AED69E8",
"versionEndExcluding": "1.0.2",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:tp-link:er603wp-4g-outdoor:-:*:*:*:*:*:*:*",
"matchCriteriaId": "EE399BF3-D90E-4B4C-80B5-819715DC366F",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:tp-link:dr3150_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "36033FDC-3905-4958-9B0E-2A834A4CDF80",
"versionEndExcluding": "1.0.1",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:tp-link:dr3150:-:*:*:*:*:*:*:*",
"matchCriteriaId": "E4B44058-8C05-4A29-81A7-113B0B6BCAE2",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:tp-link:er701-5g-outdoor_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "F5D2B103-3A11-4F8D-B94E-E9394BF39A35",
"versionEndExcluding": "1.0.3",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:tp-link:er701-5g-outdoor:-:*:*:*:*:*:*:*",
"matchCriteriaId": "2082ECC6-BC83-4D1A-A9E3-D8F3215D43E1",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:tp-link:er605w_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "6BEB928F-A260-4ADC-8AE7-EA118D6CBA4E",
"versionEndExcluding": "2.0.4",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:tp-link:er605w:2.0:*:*:*:*:*:*:*",
"matchCriteriaId": "5AE8F6F3-D20F-4151-9BEA-F3BF930A9060",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability exists in the Dynamic DNS (DDNS) functionality of TP-Link Omada Gateways. During communication with a third-party DDNS service, authentication credentials are transmitted over an unencrypted channel. An attacker who can\u00a0observe\u00a0or manipulate traffic between an affected device and the DDNS service may obtain sensitive authentication information or interfere with DDNS update operations. Exploitation requires DDNS to be configured, communication with an external DDNS service, and attacker visibility or control of the relevant network path.\u00a0\n\n\n\n\n\nSuccessful exploitation may result in disclosure of DDNS account credentials, unauthorized access to DDNS management functionality, or modification of DNS records associated with the affected deployment."
},
{
"lang": "es",
"value": "Una vulnerabilidad existe en la funcionalidad de DNS Din\u00e1mico (DDNS) de los Gateways TP-Link Omada. Durante la comunicaci\u00f3n con un servicio DDNS de terceros, las credenciales de autenticaci\u00f3n se transmiten a trav\u00e9s de un canal no cifrado. Un atacante que puede observar o manipular el tr\u00e1fico entre un dispositivo afectado y el servicio DDNS puede obtener informaci\u00f3n de autenticaci\u00f3n sensible o interferir con las operaciones de actualizaci\u00f3n de DDNS. La explotaci\u00f3n requiere que el DDNS est\u00e9 configurado, comunicaci\u00f3n con un servicio DDNS externo, y visibilidad o control del atacante de la ruta de red relevante.\n\nLa explotaci\u00f3n exitosa puede resultar en la divulgaci\u00f3n de credenciales de cuenta DDNS, acceso no autorizado a la funcionalidad de gesti\u00f3n de DDNS, o la modificaci\u00f3n de registros DNS asociados con la implementaci\u00f3n afectada."
}
],
"id": "CVE-2026-19683",
"lastModified": "2026-10-26T10:10:00.140",
"metrics": {
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "HIGH",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 7.4,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:N",
"version": "3.1"
},
"exploitabilityScore": 2.2,
"impactScore": 5.2,
"source": "nvd@nist.gov",
"type": "Primary"
}
],
"cvssMetricV40": [
{
"cvssData": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "PRESENT",
"attackVector": "NETWORK",
"availabilityRequirement": "NOT_DEFINED",
"baseScore": 6.3,
"baseSeverity": "MEDIUM",
"confidentialityRequirement": "NOT_DEFINED",
"exploitMaturity": "NOT_DEFINED",
"integrityRequirement": "NOT_DEFINED",
"modifiedAttackComplexity": "NOT_DEFINED",
"modifiedAttackRequirements": "NOT_DEFINED",
"modifiedAttackVector": "NOT_DEFINED",
"modifiedPrivilegesRequired": "NOT_DEFINED",
"modifiedSubAvailabilityImpact": "NOT_DEFINED",
"modifiedSubConfidentialityImpact": "NOT_DEFINED",
"modifiedSubIntegrityImpact": "NOT_DEFINED",
"modifiedUserInteraction": "NOT_DEFINED",
"modifiedVulnAvailabilityImpact": "NOT_DEFINED",
"modifiedVulnConfidentialityImpact": "NOT_DEFINED",
"modifiedVulnIntegrityImpact": "NOT_DEFINED",
"privilegesRequired": "NONE",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:P/PR:N/UI:N/VC:L/VI:L/VA:N/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
"version": "4.0",
"vulnAvailabilityImpact": "NONE",
"vulnConfidentialityImpact": "LOW",
"vulnIntegrityImpact": "LOW",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"source": "f23511db-6c3e-4e32-a477-6aa17d310630",
"type": "Secondary"
}
],
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2026-19683",
"options": [
{
"exploitation": "none"
},
{
"automatable": "no"
},
{
"technicalImpact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-08-20T18:55:44.295305Z",
"version": "2.0.3"
}
}
]
},
"published": "2026-08-20T19:16:51.303",
"references": [
{
"source": "f23511db-6c3e-4e32-a477-6aa17d310630",
"tags": [
"Product"
],
"url": "https://www.omadanetworks.com/en/support/download/"
},
{
"source": "f23511db-6c3e-4e32-a477-6aa17d310630",
"tags": [
"Product"
],
"url": "https://www.omadanetworks.com/us/support/download/"
},
{
"source": "f23511db-6c3e-4e32-a477-6aa17d310630",
"tags": [
"Vendor Advisory"
],
"url": "https://www.tp-link.com/us/support/faq/5256/"
}
],
"sourceIdentifier": "f23511db-6c3e-4e32-a477-6aa17d310630",
"vulnStatus": "Analyzed",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-319"
}
],
"source": "f23511db-6c3e-4e32-a477-6aa17d310630",
"type": "Secondary"
}
]
}
Drag nodes to arrange them. Double-click a related vulnerability to open it, or a source to visit its link. The Physics button on the left tunes the layout and the simulation; the legend at the bottom left hides or shows nodes by kind and by sighting type.
Sightings
| Author | Source | Type | Date | Other |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Vulnerability timeline
Sightings and recorded dates, grouped by day · UTC
How durations are calculated
Following the VTEM framework (Black Hat USA 2015), time to patch starts when the vendor or a coordinator was informed, total time to patch at discovery, and disclosure to patch at public disclosure; vendor response time runs from the report to its acknowledgement. Time to exploit and time unpatched start at the earliest discovery or report, falling back to public disclosure. Unpatched time ends at the first recorded patch, or the calculation time when no patch is recorded. Exploitation to patch shows the interval between those two events; a published proof of concept is a public exploit, not exploitation. The method is described in a publication.
Each result shows its source dates. A negative interval means the end event came first; when date-only inputs leave the order open, the result says so. Date-only inputs are approximate. The earliest evidence wins: KEV report dates and sightings are labelled as such. Records describing another vulnerability are listed but never calculated from, and a PoC alone does not establish exploitation. Missing patch evidence does not prove that no patch exists. Filters below change the event list only.
Loading timeline…
The approach is described in our paper Mapping CVEs to MITRE ATT&CK Techniques: A Curated Gold-Set Classifier and the Limits of LLM-Assisted Label Expansion.
Browse all ATT&CK techniques and the vulnerabilities related to each.
Related by attack behaviour
Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.