FKIE_CVE-2026-13584
Vulnerability from fkie_nvd - Published: 2026-07-30 07:16 - Updated: 2026-08-04 05:16
Severity
Summary
Improper Enforcement of Message Integrity During Transmission in a Communication Channel vulnerability in Mitsubishi Electric MELSEC MX Controller MX-R model, MELSEC MX Controller MX-F model, Master/local module, CC-Link IE TSN interface board, Motion module, Motion Control Board, Block-type remote module, Block-type remote module with safety functions, Analog-Digital converter module, Digital-Analog converter module, CC-Link IE TSN compatible coupler, FPGA module, Tension meter, AC Servo MELSERVO-J5, AC Servo MELSERVO-JET, Liner Track System MTR-S series Linear track control module, Inverter FR-A800/F800/E800 Series, Industrial Robot CR800-D series controller Network Base Card, CC-Link IE TSN expansion unit, CC-Link IE TSN-CC-Link IE Field Network bridge module, CC-Link IE TSN-AnyWireASLINK bridge module, Energy Measuring Unit CC-Link IE TSN Communication Unit, Industrial Computer MELIPC series, GOT3000 Series, CC-Link IE TSN Communication Unit, Motion Control Software, CC-Link IE TSN Communication Software for Windows, Analysis Support Software MELSOFT VIMA, Master/Local module Designated communication LSI DeviceKit, Master/Local module Designated communication LSI, Remote Station Communication LSI with GbE-PHY, CC-Link IE TSN Master/Local module Designated communication LSI SDK, and Remote station software development kit allows an attacker with access to a CC-Link IE TSN network to tamper with communication data (control input/output values) by sending specially crafted packets under specific timing conditions. This could allow the attacker to cause a denial-of-service (DoS) condition in the affected product by interfering with its control function or causing it to operate incorrectly.
References
Impacted products
| Vendor | Product | Version |
|---|
{
"affected": [
{
"affectedData": [
{
"defaultStatus": "unaffected",
"product": "MELSEC MX Controller MX-R model MXR300-16",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC MX Controller MX-R model MXR300-32",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC MX Controller MX-R model MXR300-64",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC MX Controller MX-R model MXR500-128",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC MX Controller MX-R model MXR500-256",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC MX Controller MX-F model MXF100-8-N32",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC MX Controller MX-F model MXF100-8-P32",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC MX Controller MX-F model MXF100-16-N32",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC MX Controller MX-F model MXF100-16-P32",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Master/local module RJ71GN11-T2",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Master/local module RJ71GN11-SX",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Master/local module RJ71GN11-EIP",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Master/local module FX5-CCLGN-MS",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CC-Link IE TSN interface board NZ81GN11-SX",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CC-Link IE TSN interface board NZ81GN11-T2",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Motion module RD78G4",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Motion module RD78G8",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Motion module RD78G16",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Motion module RD78G64",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Motion module RD78GHV",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Motion module RD78GHW",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Motion module FX5-40SSC-G",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Motion module FX5-80SSC-G",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Motion Control Board MR-EM441G",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Block-type remote module NZ2GN2S1-32D",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Block-type remote module NZ2GN2S1-32T",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Block-type remote module NZ2GN2S1-32TE",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Block-type remote module NZ2GN2S1-32DT",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Block-type remote module NZ2GN2S1-32DTE",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Block-type remote module NZ2GN2B1-32D",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Block-type remote module NZ2GN2B1-32T",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Block-type remote module NZ2GN2B1-32TE",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Block-type remote module NZ2GN2B1-32DT",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Block-type remote module NZ2GN2B1-32DTE",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Block-type remote module NZ2GNCF1-32D",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Block-type remote module NZ2GNCF1-32T",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Block-type remote module NZ2GNCE3-32D",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Block-type remote module NZ2GNCE3-32DT",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Block-type remote module NZ2GN12A4-16D",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Block-type remote module NZ2GN12A4-16DE",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Block-type remote module NZ2GN12A2-16T",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Block-type remote module NZ2GN12A2-16TE",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Block-type remote module NZ2GN12A42-16DT",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Block-type remote module NZ2GN12A42-16DTE",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Block-type remote module NZ2GN2S1-16D",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Block-type remote module NZ2GN2S1-16T",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Block-type remote module NZ2GN2S1-16TE",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Block-type remote module NZ2GN2B1-16D",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Block-type remote module NZ2GN2B1-16T",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Block-type remote module NZ2GN2B1-16TE",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Block-type remote module with safety functions NZ2GNSS2-8D",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Block-type remote module with safety functions NZ2GNSS2-8D-K",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Block-type remote module with safety functions NZ2GNSS2-8TE",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Block-type remote module with safety functions NZ2GNSS2-8TE-K",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Block-type remote module with safety functions NZ2GNSS2-16DTE",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Block-type remote module with safety functions NZ2GNSS2-16DTE-K",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Block-type remote module with safety functions NZ2GNS12A2-14DT",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Block-type remote module with safety functions NZ2GNS12A2-16DTE",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Analog-Digital converter module NZ2GN2S-60AD4",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Analog-Digital converter module NZ2GN2B-60AD4",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Digital-Analog converter module NZ2GN2S-60DA4",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Digital-Analog converter module NZ2GN2B-60DA4",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CC-Link IE TSN compatible coupler NZ2FT-GN",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "FPGA module NZ2GN2S-D41P01",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "FPGA module NZ2GN2S-D41D01",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "FPGA module NZ2GN2S-D41PD02",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Tension meter LM7-1LG",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Tension meter LM7-2LG",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "AC Servo MELSERVO-J5 MR-J5-G",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "AC Servo MELSERVO-J5 MR-J5W-G",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "AC Servo MELSERVO-J5 MR-J5-G-HS",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "AC Servo MELSERVO-J5 MR-J5-G-RJ",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "AC Servo MELSERVO-J5 MR-J5-G-LL",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "AC Servo MELSERVO-J5 MR-J5D-G4",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "AC Servo MELSERVO-J5 MR-MD333G",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "AC Servo MELSERVO-JET MR-JET-G",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "AC Servo MELSERVO-JET MR-JET-G4-HS",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Inverter FR-A800/F800/E800 Series FR-A8NCG",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Inverter FR-A800/F800/E800 Series FR-A8NCG-S",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Inverter FR-A800/F800/E800 Series FR-A800-GN",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Inverter FR-A800/F800/E800 Series FR-E800-E",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Inverter FR-A800/F800/E800 Series FR-E800-SCE",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Industrial Robot CR800-D series controller Network Base Card 2F-DQ535-TSN",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CC-Link IE TSN expansion unit FCU8-EX569",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CC-Link IE TSN-CC-Link IE Field Network bridge module NZ2GN-GFB",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CC-Link IE TSN-AnyWireASLINK bridge module NZ2AW1GNAL",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Energy Measuring Unit CC-Link IE TSN Communication Unit EMU4-CM-TSN",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Industrial Computer MELIPC series MI2532-W",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Industrial Computer MELIPC series MI2332-W",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "GOT3000 Series GT3715-FHCBD",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "GOT3000 Series GT3712-WXCBD",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "GOT3000 Series GT3715-XRBA",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "GOT3000 Series GT3715-XRBD",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "GOT3000 Series GT3712-XRBA",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "GOT3000 Series GT3712-XRBD",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "GOT3000 Series GT3710-XRBA",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "GOT3000 Series GT3710-XRBD",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "GOT3000 Series GT3708-XRBA",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "GOT3000 Series GT3708-XRBD",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CC-Link IE TSN Communication Unit GT25-J71GN13-T2",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Motion Control Software SWM-G",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Motion Control Software SWM-G-N1",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CC-Link IE TSN Communication Software for Windows SW1DND-CCIETCT-M",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Master/Local module Designated communication LSI DeviceKit NZ2KT-NPETNG51",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Master/Local module Designated communication LSI NZ2GACP610-60",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Remote Station Communication LSI with GbE-PHY NZ2GACP620-60",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Remote Station Communication LSI with GbE-PHY NZ2GACP620-300",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Remote Station Communication LSI with GbE-PHY NZ2GACP621-90",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Remote Station Communication LSI with GbE-PHY NZ2GACP621-720",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CC-Link IE TSN Master/Local module Designated communication LSI SDK SW1DNN-GN610SRC-M",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Remote station software development kit SW1DNC-GNSDK1S-M",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Remote station software development kit SW1DNC-GNSDK2S-M",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Liner Track System MTR-S series Linear track control module MTR-SCU00-4G",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Liner Track System MTR-S series Linear track control module MTR-SCU00-PG",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Analysis Support Software MELSOFT VIMA SW1DNN-VIMA-M",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
}
],
"source": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "Improper Enforcement of Message Integrity During Transmission in a Communication Channel vulnerability in Mitsubishi Electric MELSEC MX Controller MX-R model, MELSEC MX Controller MX-F model, Master/local module, CC-Link IE TSN interface board, Motion module, Motion Control Board, Block-type remote module, Block-type remote module with safety functions, Analog-Digital converter module, Digital-Analog converter module, CC-Link IE TSN compatible coupler, FPGA module, Tension meter, AC Servo MELSERVO-J5, AC Servo MELSERVO-JET, Liner Track System MTR-S series Linear track control module, Inverter FR-A800/F800/E800 Series, Industrial Robot CR800-D series controller Network Base Card, CC-Link IE TSN expansion unit, CC-Link IE TSN-CC-Link IE Field Network bridge module, CC-Link IE TSN-AnyWireASLINK bridge module, Energy Measuring Unit CC-Link IE TSN Communication Unit, Industrial Computer MELIPC series, GOT3000 Series, CC-Link IE TSN Communication Unit, Motion Control Software, CC-Link IE TSN Communication Software for Windows, Analysis Support Software MELSOFT VIMA, Master/Local module Designated communication LSI DeviceKit, Master/Local module Designated communication LSI, Remote Station Communication LSI with GbE-PHY, CC-Link IE TSN Master/Local module Designated communication LSI SDK, and Remote station software development kit allows an attacker with access to a CC-Link IE TSN network to tamper with communication data (control input/output values) by sending specially crafted packets under specific timing conditions. This could allow the attacker to cause a denial-of-service (DoS) condition in the affected product by interfering with its control function or causing it to operate incorrectly."
}
],
"id": "CVE-2026-13584",
"lastModified": "2026-08-04T05:16:37.030",
"metrics": {
"cvssMetricV40": [
{
"cvssData": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "ADJACENT",
"availabilityRequirement": "NOT_DEFINED",
"baseScore": 7.1,
"baseSeverity": "HIGH",
"confidentialityRequirement": "NOT_DEFINED",
"exploitMaturity": "NOT_DEFINED",
"integrityRequirement": "NOT_DEFINED",
"modifiedAttackComplexity": "NOT_DEFINED",
"modifiedAttackRequirements": "NOT_DEFINED",
"modifiedAttackVector": "NOT_DEFINED",
"modifiedPrivilegesRequired": "NOT_DEFINED",
"modifiedSubAvailabilityImpact": "NOT_DEFINED",
"modifiedSubConfidentialityImpact": "NOT_DEFINED",
"modifiedSubIntegrityImpact": "NOT_DEFINED",
"modifiedUserInteraction": "NOT_DEFINED",
"modifiedVulnAvailabilityImpact": "NOT_DEFINED",
"modifiedVulnConfidentialityImpact": "NOT_DEFINED",
"modifiedVulnIntegrityImpact": "NOT_DEFINED",
"privilegesRequired": "NONE",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:N/VI:H/VA:L/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
"version": "4.0",
"vulnAvailabilityImpact": "LOW",
"vulnConfidentialityImpact": "NONE",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"source": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp",
"type": "Secondary"
}
],
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2026-13584",
"options": [
{
"exploitation": "none"
},
{
"automatable": "no"
},
{
"technicalImpact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-07-30T12:54:42.601094Z",
"version": "2.0.3"
}
}
]
},
"published": "2026-07-30T07:16:56.327",
"references": [
{
"source": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp",
"url": "https://jvn.jp/vu/JVNVU98879231/"
},
{
"source": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp",
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-211-07"
},
{
"source": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp",
"url": "https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2026-005_en.pdf"
}
],
"sourceIdentifier": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp",
"vulnStatus": "Deferred",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-924"
}
],
"source": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp",
"type": "Secondary"
}
]
}
Loading…
Loading…
Experimental. This forecast is provided for visualization only and may change without notice. Do not use it for operational decisions.
Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.
Sightings
| Author | Source | Type | Date | Other |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…
Loading…