FKIE_CVE-2025-7639

Vulnerability from fkie_nvd - Published: 2026-08-14 19:17 - Updated: 2026-09-29 10:10
Summary
The vulnerability, if exploited, could allow an authenticated miscreant with "DNA Authority - Operator" privilege to tamper with serialized data, potentially resulting in code execution during deserialization under the privilege of Enterprise SCADA security group "DNA Apps".
Impacted products
Vendor Product Version

{
  "affected": [
    {
      "affectedData": [
        {
          "defaultStatus": "unaffected",
          "product": "AVEVA Enterprise SCADA",
          "vendor": "AVEVA",
          "versions": [
            {
              "status": "affected",
              "version": "2025"
            },
            {
              "lessThanOrEqual": "2024 SP1 P01",
              "status": "affected",
              "version": "2024",
              "versionType": "custom"
            },
            {
              "lessThanOrEqual": "2023 SP1",
              "status": "affected",
              "version": "2023",
              "versionType": "custom"
            },
            {
              "lessThanOrEqual": "2022 SP2 P2",
              "status": "affected",
              "version": "2022",
              "versionType": "custom"
            },
            {
              "lessThanOrEqual": "2021 SP2 P5",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            },
            {
              "status": "unaffected",
              "version": "2025 P1"
            },
            {
              "status": "unaffected",
              "version": "2024 SP1 P2"
            },
            {
              "status": "unaffected",
              "version": "2023 SP1 P1"
            },
            {
              "status": "unaffected",
              "version": "2022 SP2 P3"
            },
            {
              "status": "unaffected",
              "version": "2021 SP2 P6"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "AVEVA Enterprise SCADA HMI",
          "vendor": "AVEVA",
          "versions": [
            {
              "status": "affected",
              "version": "2024"
            },
            {
              "lessThanOrEqual": "2023_P1",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            },
            {
              "status": "affected",
              "version": "2024 R2"
            },
            {
              "status": "unaffected",
              "version": "2024 R2 HF7"
            },
            {
              "status": "unaffected",
              "version": "2024 P1"
            },
            {
              "status": "unaffected",
              "version": "2023 P2 HF1"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "AVEVA Pipeline Operations for Gas/Liquids",
          "vendor": "AVEVA",
          "versions": [
            {
              "status": "unaffected",
              "version": "2025 P1"
            },
            {
              "status": "unaffected",
              "version": "2024 SP1 P2"
            },
            {
              "status": "unaffected",
              "version": "2023 SP1 P1"
            },
            {
              "status": "unaffected",
              "version": "2022 SP2 P3"
            },
            {
              "status": "unaffected",
              "version": "2021 SP2 P6"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "AVEVA Pipeline Integrity Monitor (delivered on Pipeline Simulation media)",
          "vendor": "AVEVA",
          "versions": [
            {
              "status": "unaffected",
              "version": "2025 SP1 P2"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "AVEVA Pipeline Training Simulator (delivered on Pipeline Simulation media)",
          "vendor": "AVEVA",
          "versions": [
            {
              "status": "unaffected",
              "version": "2025 SP1 P2"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "Measurement Advisor",
          "vendor": "AVEVA",
          "versions": [
            {
              "status": "unaffected",
              "version": "2025 P1"
            },
            {
              "status": "unaffected",
              "version": "2021 SP1 HF16"
            }
          ]
        }
      ],
      "source": "ics-cert@hq.dhs.gov"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "The vulnerability, if exploited, could allow an authenticated miscreant \nwith \"DNA Authority - Operator\" privilege to tamper with serialized \ndata, potentially resulting in code execution during deserialization \nunder the privilege of Enterprise SCADA security group \"DNA Apps\"."
    },
    {
      "lang": "es",
      "value": "La vulnerabilidad, si se explota, podr\u00eda permitir a un malhechor autenticado con privilegio de \u0027DNA Authority - Operator\u0027 manipular datos serializados, lo que podr\u00eda resultar en la ejecuci\u00f3n de c\u00f3digo durante la deserializaci\u00f3n bajo el privilegio del grupo de seguridad SCADA empresarial \u0027DNA Apps\u0027."
    }
  ],
  "id": "CVE-2025-7639",
  "lastModified": "2026-09-29T10:10:00.263",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "HIGH",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 7.1,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "LOW",
          "integrityImpact": "HIGH",
          "privilegesRequired": "LOW",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:H/PR:L/UI:N/S:U/C:L/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 1.6,
        "impactScore": 5.5,
        "source": "ics-cert@hq.dhs.gov",
        "type": "Secondary"
      }
    ],
    "cvssMetricV40": [
      {
        "cvssData": {
          "Automatable": "NOT_DEFINED",
          "Recovery": "NOT_DEFINED",
          "Safety": "NOT_DEFINED",
          "attackComplexity": "HIGH",
          "attackRequirements": "NONE",
          "attackVector": "NETWORK",
          "availabilityRequirement": "NOT_DEFINED",
          "baseScore": 6.1,
          "baseSeverity": "MEDIUM",
          "confidentialityRequirement": "NOT_DEFINED",
          "exploitMaturity": "NOT_DEFINED",
          "integrityRequirement": "NOT_DEFINED",
          "modifiedAttackComplexity": "NOT_DEFINED",
          "modifiedAttackRequirements": "NOT_DEFINED",
          "modifiedAttackVector": "NOT_DEFINED",
          "modifiedPrivilegesRequired": "NOT_DEFINED",
          "modifiedSubAvailabilityImpact": "NOT_DEFINED",
          "modifiedSubConfidentialityImpact": "NOT_DEFINED",
          "modifiedSubIntegrityImpact": "NOT_DEFINED",
          "modifiedUserInteraction": "NOT_DEFINED",
          "modifiedVulnAvailabilityImpact": "NOT_DEFINED",
          "modifiedVulnConfidentialityImpact": "NOT_DEFINED",
          "modifiedVulnIntegrityImpact": "NOT_DEFINED",
          "privilegesRequired": "LOW",
          "providerUrgency": "NOT_DEFINED",
          "subAvailabilityImpact": "NONE",
          "subConfidentialityImpact": "NONE",
          "subIntegrityImpact": "NONE",
          "userInteraction": "NONE",
          "valueDensity": "NOT_DEFINED",
          "vectorString": "CVSS:4.0/AV:N/AC:H/AT:N/PR:L/UI:N/VC:L/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
          "version": "4.0",
          "vulnAvailabilityImpact": "HIGH",
          "vulnConfidentialityImpact": "LOW",
          "vulnIntegrityImpact": "HIGH",
          "vulnerabilityResponseEffort": "NOT_DEFINED"
        },
        "source": "ics-cert@hq.dhs.gov",
        "type": "Secondary"
      }
    ],
    "ssvcV203": [
      {
        "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
        "ssvcData": {
          "id": "CVE-2025-7639",
          "options": [
            {
              "exploitation": "none"
            },
            {
              "automatable": "no"
            },
            {
              "technicalImpact": "total"
            }
          ],
          "role": "CISA Coordinator",
          "timestamp": "2026-08-17T20:00:07.540175Z",
          "version": "2.0.3"
        }
      }
    ]
  },
  "published": "2026-08-14T19:17:13.380",
  "references": [
    {
      "source": "ics-cert@hq.dhs.gov",
      "url": "https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-225-01.json"
    },
    {
      "source": "ics-cert@hq.dhs.gov",
      "url": "https://www.aveva.com/content/dam/aveva/documents/support/cyber-security-updates/SecurityBulletin_AVEVA-2026-005.pdf"
    },
    {
      "source": "ics-cert@hq.dhs.gov",
      "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-225-01"
    }
  ],
  "sourceIdentifier": "ics-cert@hq.dhs.gov",
  "vulnStatus": "Deferred",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-502"
        }
      ],
      "source": "ics-cert@hq.dhs.gov",
      "type": "Secondary"
    }
  ]
}



Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.

Sightings

Author Source Type Date Other

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.

Loading…

Loading…

Loading…

Related by attack behaviour

Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.


Loading…