FKIE_CVE-2025-63205

Vulnerability from fkie_nvd - Published: 2025-11-19 18:15 - Updated: 2026-02-03 15:16
Summary
An issue was discovered in bridgetech probes VB220 IP Network Probe,VB120 Embedded IP + RF Probe, VB330 High-Capacity Probe, VB440 ST 2110 Production Analytics Probe, and NOMAD, firmware versions 6.5.0-9, allowing attackers to gain sensitive information such as administrator passwords via the /probe/core/setup/passwd endpoint. NOTE: the Supplier disagrees that 6.5.0-9 is affected, and instead reports that 5.6.0-3 and earlier are affected, and 5.6.0-4 (2020-09-21) and later are fixed.

{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:bridgetech:vb220_firmware:6.5.0-9:*:*:*:*:*:*:*",
              "matchCriteriaId": "2D7D8CF1-C66C-492D-ABF6-D531FCC42C79",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:bridgetech:vb220:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "D610E2AE-FD9A-44E0-97A6-68490DB73407",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:bridgetech:vb120_firmware:6.5.0-9:*:*:*:*:*:*:*",
              "matchCriteriaId": "0707CFD3-BA37-4377-BE38-1BD3FC6F1C50",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:bridgetech:vb120:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "F17C4BB8-D15D-4F72-A0EE-FFA316E98A61",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:bridgetech:vb330_firmware:6.5.0-9:*:*:*:*:*:*:*",
              "matchCriteriaId": "93B007C6-6FD6-4F75-B74A-4E25C90D2E9A",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:bridgetech:vb330:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "BBCB33B7-6296-4EA0-84F9-C8BC49C4390A",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:bridgetech:vb440_firmware:6.5.0-9:*:*:*:*:*:*:*",
              "matchCriteriaId": "0710088E-8FA0-4F7A-A346-974CB9EB8422",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:bridgetech:vb440:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "2146DDCD-DE8C-4792-B122-5A362C84FF2D",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:bridgetech:nomad_portable_firmware:6.5.0-9:*:*:*:*:*:*:*",
              "matchCriteriaId": "581EE039-0B78-4805-8D2C-84AA78279FA4",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:bridgetech:nomad_portable:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "FBD8F52D-3CE9-454E-81AC-8AD32D5691BB",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "An issue was discovered in bridgetech probes VB220 IP Network Probe,VB120 Embedded IP + RF Probe, VB330 High-Capacity Probe, VB440 ST 2110 Production Analytics Probe, and NOMAD, firmware versions 6.5.0-9, allowing attackers to gain sensitive information such as administrator passwords via the /probe/core/setup/passwd endpoint. NOTE: the Supplier disagrees that 6.5.0-9 is affected, and instead reports that 5.6.0-3 and earlier are affected, and 5.6.0-4 (2020-09-21) and later are fixed."
    }
  ],
  "id": "CVE-2025-63205",
  "lastModified": "2026-02-03T15:16:12.070",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "NONE",
          "baseScore": 7.5,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "NONE",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 3.6,
        "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
        "type": "Secondary"
      }
    ]
  },
  "published": "2025-11-19T18:15:48.507",
  "references": [
    {
      "source": "cve@mitre.org",
      "tags": [
        "Product"
      ],
      "url": "https://bridgetech.tv/"
    },
    {
      "source": "cve@mitre.org",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "url": "https://github.com/shiky8/my--cve-vulnerability-research/tree/main/CVE-2025-63205_bridgetech%20probes%20Information%20Disclosure"
    },
    {
      "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "url": "https://github.com/shiky8/my--cve-vulnerability-research/tree/main/CVE-2025-63205_bridgetech%20probes%20Information%20Disclosure"
    }
  ],
  "sourceIdentifier": "cve@mitre.org",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-200"
        }
      ],
      "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
      "type": "Secondary"
    }
  ]
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.

Sightings

Author Source Type Date Other

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.

Loading…

Detection rules are retrieved from Rulezet.

Loading…

Loading…