FKIE_CVE-2025-41670

Vulnerability from fkie_nvd - Published: 2026-05-27 08:16 - Updated: 2026-10-14 13:10
Summary
A local user with low privileges may be able to influence the behavior of a privileged system service by manipulating configuration or application-related files located in user-writable areas of the filesystem. The affected service processes data from locations that are not sufficiently protected against modification by low-privileged users. As the service runs with elevated privileges, successful exploitation may result in a local privilege escalation.
Impacted products
Vendor Product Version

{
  "affected": [
    {
      "affectedData": [
        {
          "defaultStatus": "unaffected",
          "product": "AXC F 1152",
          "vendor": "Phoenix Contact",
          "versions": [
            {
              "lessThan": "2026.0.3",
              "status": "affected",
              "version": "0.0.0",
              "versionType": "semver"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "AXC F 1252",
          "vendor": "Phoenix Contact",
          "versions": [
            {
              "lessThan": "2026.0.3",
              "status": "affected",
              "version": "0.0.0",
              "versionType": "semver"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "AXC F 2000 EA",
          "vendor": "Phoenix Contact",
          "versions": [
            {
              "lessThan": "2026.0.3",
              "status": "affected",
              "version": "0.0.0",
              "versionType": "semver"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "AXC F 2152",
          "vendor": "Phoenix Contact",
          "versions": [
            {
              "lessThan": "2026.0.3",
              "status": "affected",
              "version": "0.0.0",
              "versionType": "semver"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "AXC F 3152",
          "vendor": "Phoenix Contact",
          "versions": [
            {
              "lessThan": "2026.0.3",
              "status": "affected",
              "version": "0.0.0",
              "versionType": "semver"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "BPC 9102S",
          "vendor": "Phoenix Contact",
          "versions": [
            {
              "lessThan": "2026.0.3",
              "status": "affected",
              "version": "0.0.0",
              "versionType": "semver"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "EPC 1522",
          "vendor": "Phoenix Contact",
          "versions": [
            {
              "lessThan": "2026.0.3",
              "status": "affected",
              "version": "0.0.0",
              "versionType": "semver"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "RFC 4072R",
          "vendor": "Phoenix Contact",
          "versions": [
            {
              "lessThan": "2026.0.3",
              "status": "affected",
              "version": "0.0.0",
              "versionType": "semver"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "RFC 4072S",
          "vendor": "Phoenix Contact",
          "versions": [
            {
              "lessThan": "2026.0.3",
              "status": "affected",
              "version": "0.0.0",
              "versionType": "semver"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "VL3 UPC 2440 EDGE",
          "vendor": "Phoenix Contact",
          "versions": [
            {
              "lessThan": "2026.0.3",
              "status": "affected",
              "version": "0.0.0",
              "versionType": "semver"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "VPLCNEXT CONTROL 1000",
          "vendor": "Phoenix Contact",
          "versions": [
            {
              "lessThan": "2026.0.3",
              "status": "affected",
              "version": "0.0.0",
              "versionType": "semver"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "VPLCNEXT CONTROL 2000",
          "vendor": "Phoenix Contact",
          "versions": [
            {
              "lessThan": "2026.0.3",
              "status": "affected",
              "version": "0.0.0",
              "versionType": "semver"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "VPLCNEXT CONTROL 3000",
          "vendor": "Phoenix Contact",
          "versions": [
            {
              "lessThan": "2026.0.3",
              "status": "affected",
              "version": "0.0.0",
              "versionType": "semver"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "VPLCNEXT CONTROL 500",
          "vendor": "Phoenix Contact",
          "versions": [
            {
              "lessThan": "2026.0.3",
              "status": "affected",
              "version": "0.0.0",
              "versionType": "semver"
            }
          ]
        }
      ],
      "source": "info@cert.vde.com"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "A local user with low privileges may be able to influence the behavior of a privileged system service by manipulating configuration or application-related files located in user-writable areas of the filesystem. The affected service processes data from locations that are not sufficiently protected against modification by low-privileged users. As the service runs with elevated privileges, successful exploitation may result in a local privilege escalation."
    },
    {
      "lang": "es",
      "value": "Un usuario local con privilegios bajos podr\u00eda influir en el comportamiento de un servicio de sistema privilegiado manipulando archivos de configuraci\u00f3n o relacionados con la aplicaci\u00f3n ubicados en \u00e1reas del sistema de archivos escribibles por el usuario. El servicio afectado procesa datos de ubicaciones que no est\u00e1n suficientemente protegidas contra la modificaci\u00f3n por parte de usuarios con privilegios bajos. Dado que el servicio se ejecuta con privilegios elevados, una explotaci\u00f3n exitosa podr\u00eda resultar en una escalada de privilegios local."
    }
  ],
  "id": "CVE-2025-41670",
  "lastModified": "2026-10-14T13:10:00.187",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "LOCAL",
          "availabilityImpact": "HIGH",
          "baseScore": 7.8,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "LOW",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 1.8,
        "impactScore": 5.9,
        "source": "info@cert.vde.com",
        "type": "Secondary"
      }
    ],
    "cvssMetricV40": [
      {
        "cvssData": {
          "Automatable": "NOT_DEFINED",
          "Recovery": "NOT_DEFINED",
          "Safety": "NOT_DEFINED",
          "attackComplexity": "LOW",
          "attackRequirements": "NONE",
          "attackVector": "NETWORK",
          "availabilityRequirement": "NOT_DEFINED",
          "baseScore": 8.7,
          "baseSeverity": "HIGH",
          "confidentialityRequirement": "NOT_DEFINED",
          "exploitMaturity": "NOT_DEFINED",
          "integrityRequirement": "NOT_DEFINED",
          "modifiedAttackComplexity": "NOT_DEFINED",
          "modifiedAttackRequirements": "NOT_DEFINED",
          "modifiedAttackVector": "NOT_DEFINED",
          "modifiedPrivilegesRequired": "NOT_DEFINED",
          "modifiedSubAvailabilityImpact": "NOT_DEFINED",
          "modifiedSubConfidentialityImpact": "NOT_DEFINED",
          "modifiedSubIntegrityImpact": "NOT_DEFINED",
          "modifiedUserInteraction": "NOT_DEFINED",
          "modifiedVulnAvailabilityImpact": "NOT_DEFINED",
          "modifiedVulnConfidentialityImpact": "NOT_DEFINED",
          "modifiedVulnIntegrityImpact": "NOT_DEFINED",
          "privilegesRequired": "LOW",
          "providerUrgency": "NOT_DEFINED",
          "subAvailabilityImpact": "NONE",
          "subConfidentialityImpact": "NONE",
          "subIntegrityImpact": "NONE",
          "userInteraction": "NONE",
          "valueDensity": "NOT_DEFINED",
          "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
          "version": "4.0",
          "vulnAvailabilityImpact": "HIGH",
          "vulnConfidentialityImpact": "HIGH",
          "vulnIntegrityImpact": "HIGH",
          "vulnerabilityResponseEffort": "NOT_DEFINED"
        },
        "source": "info@cert.vde.com",
        "type": "Secondary"
      }
    ],
    "ssvcV203": [
      {
        "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
        "ssvcData": {
          "id": "CVE-2025-41670",
          "options": [
            {
              "exploitation": "none"
            },
            {
              "automatable": "no"
            },
            {
              "technicalImpact": "total"
            }
          ],
          "role": "CISA Coordinator",
          "timestamp": "2026-05-27T11:53:31.526293Z",
          "version": "2.0.3"
        }
      }
    ]
  },
  "published": "2026-05-27T08:16:39.920",
  "references": [
    {
      "source": "info@cert.vde.com",
      "url": "https://www.certvde.com/en/advisories/VDE-2026-050/"
    }
  ],
  "sourceIdentifier": "info@cert.vde.com",
  "vulnStatus": "Deferred",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-427"
        }
      ],
      "source": "info@cert.vde.com",
      "type": "Secondary"
    }
  ]
}



Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Drag nodes to arrange them. Double-click a related vulnerability to open it, or a source to visit its link. The Physics button on the left tunes the layout and the simulation; the legend at the bottom left hides or shows nodes by kind and by sighting type.

Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.

Sightings

Author Source Type Date Other

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Vulnerability timeline

Sightings and recorded dates, grouped by day · UTC

JSON
How durations are calculated

Following the VTEM framework (Black Hat USA 2015), time to patch starts when the vendor or a coordinator was informed, total time to patch at discovery, and disclosure to patch at public disclosure; vendor response time runs from the report to its acknowledgement. Time to exploit and time unpatched start at the earliest discovery or report, falling back to public disclosure. Unpatched time ends at the first recorded patch, or the calculation time when no patch is recorded. Exploitation to patch shows the interval between those two events; a published proof of concept is a public exploit, not exploitation. The method is described in a publication.

Each result shows its source dates. A negative interval means the end event came first; when date-only inputs leave the order open, the result says so. Date-only inputs are approximate. The earliest evidence wins: KEV report dates and sightings are labelled as such. Records describing another vulnerability are listed but never calculated from, and a PoC alone does not establish exploitation. Missing patch evidence does not prove that no patch exists. Filters below change the event list only.

Events included in the timeline

Loading timeline…


    Loading…

    Loading…

    Loading…

    Related by attack behaviour

    Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.