FKIE_CVE-2025-13845
Vulnerability from fkie_nvd - Published: 2026-01-15 19:16 - Updated: 2026-04-27 17:26
Severity ?
Summary
CWE-416: Use After Free vulnerability that could cause remote code execution when the end user imports the malicious project file (SSD file) into Rapsody.
References
Impacted products
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:schneider-electric:ecostruxure_power_build_-_rapsody:*:*:*:*:fr:*:*:*",
"matchCriteriaId": "139FB737-5979-4991-B8D1-0289CE7BFC26",
"versionEndIncluding": "2.8.1.0300",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:schneider-electric:ecostruxure_power_build_-_rapsody:*:*:*:*:nl:*:*:*",
"matchCriteriaId": "3112F8F2-CA70-42A5-B9CC-B45D4505713C",
"versionEndIncluding": "2.8.2.0000",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:schneider-electric:ecostruxure_power_build_-_rapsody:*:*:*:*:bel_en:*:*:*",
"matchCriteriaId": "74A96C2D-0AE4-4E83-9B71-1EB851C2E720",
"versionEndIncluding": "2.8.3.0100",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:schneider-electric:ecostruxure_power_build_-_rapsody:*:*:*:*:int_en:*:*:*",
"matchCriteriaId": "C6B44E48-5EE4-4490-A970-D20248509D12",
"versionEndIncluding": "2.8.4.0300",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:schneider-electric:ecostruxure_power_build_-_rapsody:*:*:*:*:esp:*:*:*",
"matchCriteriaId": "B21D31C7-EE0E-4A0B-AE3E-373F94B6E248",
"versionEndIncluding": "2.8.5.0200",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:schneider-electric:ecostruxure_power_build_-_rapsody:*:*:*:*:pt:*:*:*",
"matchCriteriaId": "4BF53F49-DEBD-4FE5-87D9-74BF6D50AC55",
"versionEndIncluding": "2.8.7.0100",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:schneider-electric:ecostruxure_power_build_-_rapsody:*:*:*:*:bel_fr:*:*:*",
"matchCriteriaId": "ED8F7CF9-F7FC-46EF-8420-32E779333D88",
"versionEndIncluding": "2.8.8.0100",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "CWE-416: Use After Free vulnerability that could cause remote code execution when the end user imports the malicious project file (SSD file) into Rapsody."
},
{
"lang": "es",
"value": "CWE-416: Vulnerabilidad Use After Free que podr\u00eda causar ejecuci\u00f3n remota de c\u00f3digo cuando el usuario final importa el archivo de proyecto malicioso (archivo SSD) en Rapsody."
}
],
"id": "CVE-2025-13845",
"lastModified": "2026-04-27T17:26:56.707",
"metrics": {
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 1.8,
"impactScore": 5.9,
"source": "nvd@nist.gov",
"type": "Primary"
}
],
"cvssMetricV40": [
{
"cvssData": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "LOCAL",
"availabilityRequirement": "NOT_DEFINED",
"baseScore": 8.4,
"baseSeverity": "HIGH",
"confidentialityRequirement": "NOT_DEFINED",
"exploitMaturity": "NOT_DEFINED",
"integrityRequirement": "NOT_DEFINED",
"modifiedAttackComplexity": "NOT_DEFINED",
"modifiedAttackRequirements": "NOT_DEFINED",
"modifiedAttackVector": "NOT_DEFINED",
"modifiedPrivilegesRequired": "NOT_DEFINED",
"modifiedSubAvailabilityImpact": "NOT_DEFINED",
"modifiedSubConfidentialityImpact": "NOT_DEFINED",
"modifiedSubIntegrityImpact": "NOT_DEFINED",
"modifiedUserInteraction": "NOT_DEFINED",
"modifiedVulnAvailabilityImpact": "NOT_DEFINED",
"modifiedVulnConfidentialityImpact": "NOT_DEFINED",
"modifiedVulnIntegrityImpact": "NOT_DEFINED",
"privilegesRequired": "NONE",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "ACTIVE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:A/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"source": "cybersecurity@se.com",
"type": "Secondary"
}
]
},
"published": "2026-01-15T19:16:02.937",
"references": [
{
"source": "cybersecurity@se.com",
"tags": [
"Vendor Advisory"
],
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2026-013-04\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2026-013-04.pdf"
}
],
"sourceIdentifier": "cybersecurity@se.com",
"vulnStatus": "Analyzed",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-416"
}
],
"source": "cybersecurity@se.com",
"type": "Primary"
}
]
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…
Loading…