FKIE_CVE-2024-50376
Vulnerability from fkie_nvd - Published: 2024-11-26 11:22 - Updated: 2026-01-23 18:07
Severity ?
7.3 (High) - CVSS:3.1/AV:A/AC:L/PR:N/UI:R/S:U/C:N/I:H/A:H
5.2 (Medium) - CVSS:3.1/AV:A/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N
5.2 (Medium) - CVSS:3.1/AV:A/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N
Summary
A CWE-79 "Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (<= 1.6.3), EKI-6333AC-2GD (<= v1.6.3) and EKI-6333AC-1GPO (<= v1.2.1). The vulnerability can be exploited remotely leveraging a rogue Wi-Fi access point with a malicious SSID.
References
| URL | Tags | ||
|---|---|---|---|
| prodsec@nozominetworks.com | https://www.nozominetworks.com/labs/vulnerability-advisories-cve-2024-50376 | Third Party Advisory |
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| advantech | eki-6333ac-2g_firmware | * | |
| advantech | eki-6333ac-2g | - | |
| advantech | eki-6333ac-2gd_firmware | * | |
| advantech | eki-6333ac-2gd | - | |
| advantech | eki-6333ac-1gpo_firmware | * | |
| advantech | eki-6333ac-1gpo | - |
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:advantech:eki-6333ac-2g_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "B5E027C8-2521-45FC-BABB-4A6E3341F883",
"versionEndExcluding": "1.6.5",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:advantech:eki-6333ac-2g:-:*:*:*:*:*:*:*",
"matchCriteriaId": "B3B63DF4-0184-4108-B48B-D31179104701",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:advantech:eki-6333ac-2gd_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "447F8AEB-2C7C-411A-893C-11C2F7588C82",
"versionEndExcluding": "1.6.5",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:advantech:eki-6333ac-2gd:-:*:*:*:*:*:*:*",
"matchCriteriaId": "02F70DBA-2D4C-4407-885D-71887A1A7979",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:advantech:eki-6333ac-1gpo_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "828B9D05-0064-4690-A624-D3BF659BD316",
"versionEndExcluding": "1.2.2",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:advantech:eki-6333ac-1gpo:-:*:*:*:*:*:*:*",
"matchCriteriaId": "D2A73A2B-9FD5-4971-8FFF-1BA14BCCB37B",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "A CWE-79 \"Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027)\" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (\u003c= 1.6.3), EKI-6333AC-2GD (\u003c= v1.6.3) and EKI-6333AC-1GPO (\u003c= v1.2.1). The vulnerability can be exploited remotely leveraging a rogue Wi-Fi access point with a malicious SSID."
},
{
"lang": "es",
"value": "Se descubri\u00f3 una vulnerabilidad CWE-79 \"Neutralizaci\u00f3n incorrecta de la entrada durante la generaci\u00f3n de p\u00e1ginas web (\u0027Cross-site Scripting\u0027)\" que afectaba a los siguientes dispositivos fabricados por Advantech: EKI-6333AC-2G (\u0026lt;= 1.6.3), EKI-6333AC-2GD (\u0026lt;= v1.6.3) y EKI-6333AC-1GPO (\u0026lt;= v1.2.1). La vulnerabilidad se puede explotar de forma remota utilizando un punto de acceso Wi-Fi no autorizado con un SSID malicioso."
}
],
"id": "CVE-2024-50376",
"lastModified": "2026-01-23T18:07:48.187",
"metrics": {
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.3,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:R/S:U/C:N/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 2.1,
"impactScore": 5.2,
"source": "prodsec@nozominetworks.com",
"type": "Secondary"
},
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "NONE",
"baseScore": 5.2,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"privilegesRequired": "NONE",
"scope": "CHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N",
"version": "3.1"
},
"exploitabilityScore": 2.1,
"impactScore": 2.7,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2024-11-26T11:22:08.323",
"references": [
{
"source": "prodsec@nozominetworks.com",
"tags": [
"Third Party Advisory"
],
"url": "https://www.nozominetworks.com/labs/vulnerability-advisories-cve-2024-50376"
}
],
"sourceIdentifier": "prodsec@nozominetworks.com",
"vulnStatus": "Analyzed",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-78"
}
],
"source": "prodsec@nozominetworks.com",
"type": "Secondary"
},
{
"description": [
{
"lang": "en",
"value": "CWE-79"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…
Loading…