FKIE_CVE-2024-46671

Vulnerability from fkie_nvd - Published: 2025-04-08 14:15 - Updated: 2026-06-17 07:55
Summary
An Incorrect User Management vulnerability [CWE-286] in FortiWeb version 7.6.2 and below, version 7.4.6 and below, version 7.2.10 and below, version 7.0.11 and below widgets dashboard may allow an authenticated attacker with at least read-only admin permission to perform operations on the dashboard of other administrators via crafted requests.
Impacted products
Vendor Product Version
fortinet fortiweb *
fortinet fortiweb *
fortinet fortiweb *

{
  "affected": [
    {
      "affectedData": [
        {
          "defaultStatus": "unaffected",
          "product": "FortiWeb",
          "vendor": "Fortinet",
          "versions": [
            {
              "lessThanOrEqual": "7.6.2",
              "status": "affected",
              "version": "7.6.0",
              "versionType": "semver"
            },
            {
              "lessThanOrEqual": "7.4.6",
              "status": "affected",
              "version": "7.4.0",
              "versionType": "semver"
            },
            {
              "lessThanOrEqual": "7.2.10",
              "status": "affected",
              "version": "7.2.0",
              "versionType": "semver"
            },
            {
              "lessThanOrEqual": "7.0.11",
              "status": "affected",
              "version": "7.0.0",
              "versionType": "semver"
            }
          ]
        }
      ],
      "source": "psirt@fortinet.com"
    }
  ],
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:fortinet:fortiweb:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "3E3D4A84-295A-4CB9-8F4D-D7E30F7E747A",
              "versionEndExcluding": "7.2.11",
              "versionStartIncluding": "7.0.0",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:fortinet:fortiweb:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "F78CFE46-966D-4E2A-AF02-B8C1A2F74C67",
              "versionEndExcluding": "7.4.7",
              "versionStartIncluding": "7.4.0",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:fortinet:fortiweb:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "A7FD2EFC-0161-4E00-A208-5AA893735ECC",
              "versionEndExcluding": "7.6.3",
              "versionStartIncluding": "7.6.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "An Incorrect User Management vulnerability [CWE-286] in FortiWeb version 7.6.2 and below, version 7.4.6 and below, version 7.2.10 and below, version 7.0.11 and below widgets dashboard may allow an authenticated attacker with at least read-only admin permission to perform operations on the dashboard of other administrators via crafted requests."
    },
    {
      "lang": "es",
      "value": "Una vulnerabilidad de administraci\u00f3n incorrecta de usuarios [CWE-286] en los widgets del panel de control de FortiWeb versi\u00f3n 7.6.2 y anteriores, versi\u00f3n 7.4.6 y anteriores, versi\u00f3n 7.2.10 y anteriores, versi\u00f3n 7.0.11 y anteriores puede permitir que un atacante autenticado con al menos permiso de administrador de solo lectura realice operaciones en el panel de control de otros administradores a trav\u00e9s de solicitudes manipuladas."
    }
  ],
  "id": "CVE-2024-46671",
  "lastModified": "2026-06-17T07:55:41.960",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "HIGH",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 6.2,
          "baseSeverity": "MEDIUM",
          "confidentialityImpact": "LOW",
          "integrityImpact": "HIGH",
          "privilegesRequired": "HIGH",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:H/PR:H/UI:N/S:U/C:L/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 0.7,
        "impactScore": 5.5,
        "source": "psirt@fortinet.com",
        "type": "Secondary"
      },
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 7.2,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "HIGH",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 1.2,
        "impactScore": 5.9,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ],
    "ssvcV203": [
      {
        "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
        "ssvcData": {
          "id": "CVE-2024-46671",
          "options": [
            {
              "exploitation": "none"
            },
            {
              "automatable": "no"
            },
            {
              "technicalImpact": "total"
            }
          ],
          "role": "CISA Coordinator",
          "timestamp": "2025-04-08T14:28:42.465014Z",
          "version": "2.0.3"
        }
      }
    ]
  },
  "published": "2025-04-08T14:15:31.740",
  "references": [
    {
      "source": "psirt@fortinet.com",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://fortiguard.fortinet.com/psirt/FG-IR-24-184"
    }
  ],
  "sourceIdentifier": "psirt@fortinet.com",
  "vulnStatus": "Analyzed",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-286"
        }
      ],
      "source": "psirt@fortinet.com",
      "type": "Secondary"
    }
  ]
}



Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Drag nodes to arrange them. Double-click a related vulnerability to open it, or a source to visit its link. The Physics button on the left tunes the layout and the simulation; the legend at the bottom left hides or shows nodes by kind and by sighting type.

Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.

Sightings

Author Source Type Date Other

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Vulnerability timeline

Sightings and recorded dates, grouped by day · UTC

JSON
Events included in the timeline

Loading timeline…


    Loading…

    Loading…

    Loading…

    Related by attack behaviour

    Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.