FKIE_CVE-2024-41720
Vulnerability from fkie_nvd - Published: 2024-08-05 05:15 - Updated: 2026-06-17 07:48
Severity
8.0 (High) - CVSS:3.1/AV:A/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
8.0 (High) - CVSS:3.1/AV:A/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
8.0 (High) - CVSS:3.1/AV:A/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Summary
Incorrect permission assignment for critical resource issue exists in ZWX-2000CSW2-HN firmware versions prior to Ver.0.3.15, which may allow a network-adjacent authenticated attacker to alter the configuration of the device.
References
| URL | Tags | ||
|---|---|---|---|
| vultures@jpcert.or.jp | https://jvn.jp/en/jp/JVN70666401/ | Third Party Advisory | |
| vultures@jpcert.or.jp | https://www.zexelon.co.jp/pdf/jvn70666401.pdf | Vendor Advisory |
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| zexelon | zwx-2000csw2-hn_firmware | * | |
| zexelon | zwx-2000csw2-hn | * |
{
"affected": [
{
"affectedData": [
{
"product": "ZWX-2000CSW2-HN",
"vendor": "ZEXELON CO., LTD.",
"versions": [
{
"status": "affected",
"version": "firmware versions prior to Ver.0.3.15"
}
]
}
],
"source": "vultures@jpcert.or.jp"
}
],
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:zexelon:zwx-2000csw2-hn_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "C9F38FB9-D0CB-48E9-B09A-DF962CA0B0B6",
"versionEndExcluding": "0.3.15",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:zexelon:zwx-2000csw2-hn:*:*:*:*:*:*:*:*",
"matchCriteriaId": "A2349E09-CC89-41F6-AA4A-14B96D10EED8",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "Incorrect permission assignment for critical resource issue exists in ZWX-2000CSW2-HN firmware versions prior to Ver.0.3.15, which may allow a network-adjacent authenticated attacker to alter the configuration of the device."
},
{
"lang": "es",
"value": "Existe una asignaci\u00f3n de permisos incorrecta para problemas de recursos cr\u00edticos en versiones de firmware ZWX-2000CSW2-HN anteriores a la versi\u00f3n 0.3.15, lo que puede permitir que un atacante autenticado adyacente a la red altere la configuraci\u00f3n del dispositivo."
}
],
"id": "CVE-2024-41720",
"lastModified": "2026-06-17T07:48:07.430",
"metrics": {
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.0,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 2.1,
"impactScore": 5.9,
"source": "nvd@nist.gov",
"type": "Primary"
},
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.0,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 2.1,
"impactScore": 5.9,
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"type": "Secondary"
}
],
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2024-41720",
"options": [
{
"exploitation": "none"
},
{
"automatable": "no"
},
{
"technicalImpact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-08-05T18:45:07.840217Z",
"version": "2.0.3"
}
}
]
},
"published": "2024-08-05T05:15:39.637",
"references": [
{
"source": "vultures@jpcert.or.jp",
"tags": [
"Third Party Advisory"
],
"url": "https://jvn.jp/en/jp/JVN70666401/"
},
{
"source": "vultures@jpcert.or.jp",
"tags": [
"Vendor Advisory"
],
"url": "https://www.zexelon.co.jp/pdf/jvn70666401.pdf"
}
],
"sourceIdentifier": "vultures@jpcert.or.jp",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-732"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
},
{
"description": [
{
"lang": "en",
"value": "CWE-732"
}
],
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"type": "Secondary"
}
]
}
Loading…
Loading…
Experimental. This forecast is provided for visualization only and may change without notice. Do not use it for operational decisions.
Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.
Sightings
| Author | Source | Type | Date | Other |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…
Loading…