FKIE_CVE-2024-1573

Vulnerability from fkie_nvd - Published: 2024-07-04 09:15 - Updated: 2026-06-17 07:04
Summary
Missing Authentication for Critical Function vulnerability in the mobile monitoring feature of Mitsubishi Electric GENESIS64 versions 10.97.2 and prior, Mitsubishi Electric ICONICS Suite versions 10.97.2 and prior, Mitsubishi Electric Hyper Historian versions 10.97.2 and prior, Mitsubishi Electric AnalytiX versions 10.97.2 and prior, Mitsubishi Electric MobileHMI versions 10.97.2 and prior, Mitsubishi Electric IoTWorX version 10.95, Mitsubishi Electric MC Works64 all versions, Mitsubishi Electric Iconics Digital Solutions GENESIS64 versions 10.97.2 and prior, Mitsubishi Electric Iconics Digital Solutions ICONICS Suite versions 10.97.2 and prior, Mitsubishi Electric Iconics Digital Solutions Hyper Historian versions 10.97.2 and prior, Mitsubishi Electric Iconics Digital Solutions AnalytiX versions 10.97.2 and prior, Mitsubishi Electric Iconics Digital Solutions MobileHMI versions 10.97.2 and prior, and Mitsubishi Electric Iconics Digital Solutions IoTWorX version 10.95 allows a remote unauthenticated attacker to bypass proper authentication and log in to the system when all of the following conditions are met: (1) Active Directory is used in the security setting (2) "Automatic log in" option is enabled in the security setting (3) The IcoAnyGlass IIS Application Pool is running under an Active Directory Domain Account. (4) The IcoAnyGlass IIS Application Pool account is included in GENESIS64, ICONCIS Suite, and MC Works64 Security and has permission to log in.
Impacted products
Vendor Product Version

{
  "affected": [
    {
      "affectedData": [
        {
          "defaultStatus": "unaffected",
          "product": "GENESIS64",
          "vendor": "Mitsubishi Electric Iconics Digital Solutions",
          "versions": [
            {
              "status": "affected",
              "version": "versions 10.97.2 and prior"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "GENESIS64",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "versions 10.97.2 and prior"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "ICONICS Suite",
          "vendor": "Mitsubishi Electric Iconics Digital Solutions",
          "versions": [
            {
              "status": "affected",
              "version": "versions 10.97.2 and prior"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "ICONICS Suite",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "versions 10.97.2 and prior"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "Hyper Historian",
          "vendor": "Mitsubishi Electric Iconics Digital Solutions",
          "versions": [
            {
              "status": "affected",
              "version": "versions 10.97.2 and prior"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "Hyper Historian",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "versions 10.97.2 and prior"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "AnalytiX",
          "vendor": "Mitsubishi Electric Iconics Digital Solutions",
          "versions": [
            {
              "status": "affected",
              "version": "versions 10.97.2 and prior"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "AnalytiX",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "versions 10.97.2 and prior"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MobileHMI",
          "vendor": "Mitsubishi Electric Iconics Digital Solutions",
          "versions": [
            {
              "status": "affected",
              "version": "versions 10.97.2 and prior"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MobileHMI",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "versions 10.97.2 and prior"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "IoTWorX",
          "vendor": "Mitsubishi Electric Iconics Digital Solutions",
          "versions": [
            {
              "status": "affected",
              "version": "version 10.95"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "IoTWorX",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "version 10.95"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MC Works64",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        }
      ],
      "source": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp"
    },
    {
      "affectedData": [
        {
          "cpes": [
            "cpe:2.3:a:iconics:genesis64:10.97:*:*:*:*:*:*:*"
          ],
          "defaultStatus": "unaffected",
          "product": "genesis64",
          "vendor": "iconics",
          "versions": [
            {
              "lessThan": "10.97.92",
              "status": "affected",
              "version": "10.97",
              "versionType": "custom"
            }
          ]
        },
        {
          "cpes": [
            "cpe:2.3:a:mitsubishielectric:mc_works64:-:*:*:*:*:*:*:*"
          ],
          "defaultStatus": "unaffected",
          "product": "mc_works64",
          "vendor": "mitsubishielectric",
          "versions": [
            {
              "lessThanOrEqual": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "Missing Authentication for Critical Function vulnerability in the mobile monitoring feature of Mitsubishi Electric GENESIS64 versions 10.97.2 and prior, Mitsubishi Electric ICONICS Suite versions 10.97.2 and prior, Mitsubishi Electric Hyper Historian versions 10.97.2 and prior, Mitsubishi Electric AnalytiX versions 10.97.2 and prior, Mitsubishi Electric MobileHMI versions 10.97.2 and prior, Mitsubishi Electric IoTWorX version 10.95, Mitsubishi Electric MC Works64 all versions, Mitsubishi Electric Iconics Digital Solutions GENESIS64 versions 10.97.2 and prior, Mitsubishi Electric Iconics Digital Solutions ICONICS Suite versions 10.97.2 and prior, Mitsubishi Electric Iconics Digital Solutions Hyper Historian versions 10.97.2 and prior, Mitsubishi Electric Iconics Digital Solutions AnalytiX versions 10.97.2 and prior, Mitsubishi Electric Iconics Digital Solutions MobileHMI versions 10.97.2 and prior, and Mitsubishi Electric Iconics Digital Solutions IoTWorX version 10.95 allows a remote unauthenticated attacker to bypass proper authentication and log in to the system when all of the following conditions are met: (1) Active Directory is used in the security setting (2) \"Automatic log in\" option is enabled in the security setting (3) The IcoAnyGlass IIS Application Pool is running under an Active Directory Domain Account. (4) The IcoAnyGlass IIS Application Pool account is included in GENESIS64, ICONCIS Suite, and MC Works64 Security and has permission to log in."
    },
    {
      "lang": "es",
      "value": "Vulnerabilidad de autenticaci\u00f3n incorrecta en la funci\u00f3n de monitoreo m\u00f3vil de ICONICS GENESIS64 versiones 10.97 a 10.97.2, Mitsubishi Electric GENESIS64 versiones 10.97 a 10.97.2 y Mitsubishi Electric MC Works64 todas las versiones permite que un atacante remoto no autenticado omita la autenticaci\u00f3n adecuada e inicie sesi\u00f3n en el sistema cuando Se cumplen todas las condiciones siguientes: * Se utiliza Active Directory en la configuraci\u00f3n de seguridad. * La opci\u00f3n \"Inicio de sesi\u00f3n autom\u00e1tico\" est\u00e1 habilitada en la configuraci\u00f3n de seguridad. * El grupo de aplicaciones IcoAnyGlass IIS se ejecuta en una cuenta de dominio de Active Directory. * La cuenta del grupo de aplicaciones IcoAnyGlass IIS est\u00e1 incluida en GENESIS64TM y MC Works64 Security y tiene permiso para iniciar sesi\u00f3n."
    }
  ],
  "id": "CVE-2024-1573",
  "lastModified": "2026-06-17T07:04:33.283",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "HIGH",
          "attackVector": "NETWORK",
          "availabilityImpact": "NONE",
          "baseScore": 5.9,
          "baseSeverity": "MEDIUM",
          "confidentialityImpact": "NONE",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:H/A:N",
          "version": "3.1"
        },
        "exploitabilityScore": 2.2,
        "impactScore": 3.6,
        "source": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp",
        "type": "Secondary"
      }
    ],
    "ssvcV203": [
      {
        "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
        "ssvcData": {
          "id": "CVE-2024-1573",
          "options": [
            {
              "exploitation": "none"
            },
            {
              "automatable": "no"
            },
            {
              "technicalImpact": "total"
            }
          ],
          "role": "CISA Coordinator",
          "timestamp": "2024-07-05T14:46:51.356597Z",
          "version": "2.0.3"
        }
      }
    ]
  },
  "published": "2024-07-04T09:15:03.260",
  "references": [
    {
      "source": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp",
      "url": "https://jvn.jp/vu/JVNVU98894016/"
    },
    {
      "source": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp",
      "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-184-03"
    },
    {
      "source": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp",
      "url": "https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2024-004_en.pdf"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "url": "https://jvn.jp/vu/JVNVU98894016/"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-184-03"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2024-004_en.pdf"
    }
  ],
  "sourceIdentifier": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp",
  "vulnStatus": "Deferred",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-306"
        }
      ],
      "source": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp",
      "type": "Secondary"
    }
  ]
}



Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Drag nodes to arrange them. Double-click a related vulnerability to open it, or a source to visit its link. The Physics button on the left tunes the layout and the simulation; the legend at the bottom left hides or shows nodes by kind and by sighting type.

Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.

Sightings

Author Source Type Date Other

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Vulnerability timeline

Sightings and recorded dates, grouped by day · UTC

JSON
How durations are calculated

Following the VTEM framework (Black Hat USA 2015), time to patch starts when the vendor or a coordinator was informed, total time to patch at discovery, and disclosure to patch at public disclosure; vendor response time runs from the report to its acknowledgement. Time to exploit and time unpatched start at the earliest discovery or report, falling back to public disclosure. Unpatched time ends at the first recorded patch, or the calculation time when no patch is recorded. Exploitation to patch shows the interval between those two events; a published proof of concept is a public exploit, not exploitation.

Each result shows its source dates. A negative interval means the end event came first; when date-only inputs leave the order open, the result says so. Date-only inputs are approximate. The earliest evidence wins: KEV report dates and sightings are labelled as such. Records describing another vulnerability are listed but never calculated from, and a PoC alone does not establish exploitation. Missing patch evidence does not prove that no patch exists. Filters below change the event list only.

Events included in the timeline

Loading timeline…


    Loading…

    Loading…

    Loading…

    Related by attack behaviour

    Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.