FKIE_CVE-2022-47848

Vulnerability from fkie_nvd - Published: 2023-09-15 16:15 - Updated: 2024-11-21 07:32
Summary
An issue was discovered in Bezeq Vtech NB403-IL version BZ_2.02.07.09.13.01 and Vtech IAD604-IL versions BZ_2.02.07.09.13.01, BZ_2.02.07.09.13T, and BZ_2.02.07.09.09T, allows remote attackers to gain sensitive information via rootDesc.xml page of the UPnP service.
Impacted products
Vendor Product Version
bezeq vtech_nb403-il_firmware bz_2.02.07.09.13.01
bezeq vtech_nb403-il -
bezeq vtech_iad604-il_firmware bz_2.02.07.09.09t
bezeq vtech_iad604-il_firmware bz_2.02.07.09.13.01
bezeq vtech_iad604-il_firmware bz_2.02.07.09.13t
bezeq vtech_iad604-il -

{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:bezeq:vtech_nb403-il_firmware:bz_2.02.07.09.13.01:*:*:*:*:*:*:*",
              "matchCriteriaId": "4B02C038-F636-4C46-A7D8-2A4F7BD069B0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:bezeq:vtech_nb403-il:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "72F41356-838A-4640-9C7D-AA92BFA550ED",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:bezeq:vtech_iad604-il_firmware:bz_2.02.07.09.09t:*:*:*:*:*:*:*",
              "matchCriteriaId": "01633E21-8C51-47A1-A04A-78A1796AE684",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:bezeq:vtech_iad604-il_firmware:bz_2.02.07.09.13.01:*:*:*:*:*:*:*",
              "matchCriteriaId": "54765A58-0E2D-4564-A082-B23A641ECD4B",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:bezeq:vtech_iad604-il_firmware:bz_2.02.07.09.13t:*:*:*:*:*:*:*",
              "matchCriteriaId": "352EB738-B6D1-4D50-B091-199AF43DA11A",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:bezeq:vtech_iad604-il:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "1831376D-EC0C-4AD5-BA34-6A8E09B10915",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "An issue was discovered in Bezeq Vtech NB403-IL version BZ_2.02.07.09.13.01 and Vtech IAD604-IL versions BZ_2.02.07.09.13.01, BZ_2.02.07.09.13T, and BZ_2.02.07.09.09T, allows remote attackers to gain sensitive information via rootDesc.xml page of the UPnP service."
    },
    {
      "lang": "es",
      "value": "Se descubri\u00f3 un problema en Bezeq Vtech NB403-IL versi\u00f3n BZ_2.02.07.09.13.01 y Vtech IAD604-IL versiones BZ_2.02.07.09.13.01, BZ_2.02.07.09.13T y BZ_2.02.07.09.09T, que permite a atacantes remotos para obtener informaci\u00f3n confidencial a trav\u00e9s de la p\u00e1gina rootDesc.xml del servicio UPnP."
    }
  ],
  "id": "CVE-2022-47848",
  "lastModified": "2024-11-21T07:32:24.743",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "NONE",
          "baseScore": 7.5,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "NONE",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 3.6,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2023-09-15T16:15:07.687",
  "references": [
    {
      "source": "cve@mitre.org",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "url": "https://00xbyte.github.io/posts/bezeq-router-auth-bypass/"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "url": "https://00xbyte.github.io/posts/bezeq-router-auth-bypass/"
    }
  ],
  "sourceIdentifier": "cve@mitre.org",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-287"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.

Sightings

Author Source Type Date Other

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.

Loading…

Detection rules are retrieved from Rulezet.

Loading…

Loading…