FKIE_CVE-2022-47848
Vulnerability from fkie_nvd - Published: 2023-09-15 16:15 - Updated: 2024-11-21 07:32
Severity
Summary
An issue was discovered in Bezeq Vtech NB403-IL version BZ_2.02.07.09.13.01 and Vtech IAD604-IL versions BZ_2.02.07.09.13.01, BZ_2.02.07.09.13T, and BZ_2.02.07.09.09T, allows remote attackers to gain sensitive information via rootDesc.xml page of the UPnP service.
References
| URL | Tags | ||
|---|---|---|---|
| cve@mitre.org | https://00xbyte.github.io/posts/bezeq-router-auth-bypass/ | Exploit, Third Party Advisory | |
| af854a3a-2127-422b-91ae-364da2661108 | https://00xbyte.github.io/posts/bezeq-router-auth-bypass/ | Exploit, Third Party Advisory |
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| bezeq | vtech_nb403-il_firmware | bz_2.02.07.09.13.01 | |
| bezeq | vtech_nb403-il | - | |
| bezeq | vtech_iad604-il_firmware | bz_2.02.07.09.09t | |
| bezeq | vtech_iad604-il_firmware | bz_2.02.07.09.13.01 | |
| bezeq | vtech_iad604-il_firmware | bz_2.02.07.09.13t | |
| bezeq | vtech_iad604-il | - |
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:bezeq:vtech_nb403-il_firmware:bz_2.02.07.09.13.01:*:*:*:*:*:*:*",
"matchCriteriaId": "4B02C038-F636-4C46-A7D8-2A4F7BD069B0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:bezeq:vtech_nb403-il:-:*:*:*:*:*:*:*",
"matchCriteriaId": "72F41356-838A-4640-9C7D-AA92BFA550ED",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:bezeq:vtech_iad604-il_firmware:bz_2.02.07.09.09t:*:*:*:*:*:*:*",
"matchCriteriaId": "01633E21-8C51-47A1-A04A-78A1796AE684",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:bezeq:vtech_iad604-il_firmware:bz_2.02.07.09.13.01:*:*:*:*:*:*:*",
"matchCriteriaId": "54765A58-0E2D-4564-A082-B23A641ECD4B",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:bezeq:vtech_iad604-il_firmware:bz_2.02.07.09.13t:*:*:*:*:*:*:*",
"matchCriteriaId": "352EB738-B6D1-4D50-B091-199AF43DA11A",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:bezeq:vtech_iad604-il:-:*:*:*:*:*:*:*",
"matchCriteriaId": "1831376D-EC0C-4AD5-BA34-6A8E09B10915",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "An issue was discovered in Bezeq Vtech NB403-IL version BZ_2.02.07.09.13.01 and Vtech IAD604-IL versions BZ_2.02.07.09.13.01, BZ_2.02.07.09.13T, and BZ_2.02.07.09.09T, allows remote attackers to gain sensitive information via rootDesc.xml page of the UPnP service."
},
{
"lang": "es",
"value": "Se descubri\u00f3 un problema en Bezeq Vtech NB403-IL versi\u00f3n BZ_2.02.07.09.13.01 y Vtech IAD604-IL versiones BZ_2.02.07.09.13.01, BZ_2.02.07.09.13T y BZ_2.02.07.09.09T, que permite a atacantes remotos para obtener informaci\u00f3n confidencial a trav\u00e9s de la p\u00e1gina rootDesc.xml del servicio UPnP."
}
],
"id": "CVE-2022-47848",
"lastModified": "2024-11-21T07:32:24.743",
"metrics": {
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 3.6,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2023-09-15T16:15:07.687",
"references": [
{
"source": "cve@mitre.org",
"tags": [
"Exploit",
"Third Party Advisory"
],
"url": "https://00xbyte.github.io/posts/bezeq-router-auth-bypass/"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Exploit",
"Third Party Advisory"
],
"url": "https://00xbyte.github.io/posts/bezeq-router-auth-bypass/"
}
],
"sourceIdentifier": "cve@mitre.org",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-287"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
Loading…
Loading…
Experimental. This forecast is provided for visualization only and may change without notice. Do not use it for operational decisions.
Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.
Sightings
| Author | Source | Type | Date | Other |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…
Loading…