FKIE_CVE-2022-3752

Vulnerability from fkie_nvd - Published: 2022-12-19 23:15 - Updated: 2026-06-17 05:00
Summary
An unauthorized user could use a specially crafted sequence of Ethernet/IP messages, combined with heavy traffic loading to cause a denial-of-service condition in Rockwell Automation Logix controllers resulting in a major non-recoverable fault. If the target device becomes unavailable, a user would have to clear the fault and redownload the user project file to bring the device back online and continue normal operation.

{
  "affected": [
    {
      "affectedData": [
        {
          "defaultStatus": "unaffected",
          "product": "CompactLogix 5480",
          "vendor": "Rockwell Automation",
          "versions": [
            {
              "status": "affected",
              "version": "32.011 and later"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "ControlLogix 5580 ",
          "vendor": "Rockwell Automation",
          "versions": [
            {
              "status": "affected",
              "version": "31.011 and later"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "GuardLogix 5580",
          "vendor": "Rockwell Automation",
          "versions": [
            {
              "status": "affected",
              "version": "31.011 and later"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "Compact GuardLogix 5380",
          "vendor": "Rockwell Automation",
          "versions": [
            {
              "status": "affected",
              "version": "31.011 and later"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "CompactLogix 5380",
          "vendor": "Rockwell Automation",
          "versions": [
            {
              "status": "affected",
              "version": "31.011 and later"
            }
          ]
        }
      ],
      "source": "PSIRT@rockwellautomation.com"
    }
  ],
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:rockwellautomation:compactlogix_5480_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "A3BB8945-AC46-463C-A7D9-15584AD0FA68",
              "versionStartIncluding": "32.011",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:rockwellautomation:compactlogix_5480:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "80F4F5BE-07DF-402A-BF98-34FBA6A11968",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:rockwellautomation:compactlogix_5580_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "EDD27C92-CC9B-4780-B7AC-8ECBE1FF7C77",
              "versionStartIncluding": "31.011",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:rockwellautomation:compactlogix_5580:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "CEA62D6E-168F-4EEC-9E90-C679273C1CDB",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:rockwellautomation:guardlogix_5580_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "25846D71-4F46-4C50-BB76-5D692DE9ACFE",
              "versionStartIncluding": "32.011",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:rockwellautomation:guardlogix_5580:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "006B7683-9FDF-4748-BA28-2EA22613E092",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:rockwellautomation:compact_guardlogix_5380_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "E187CC9F-3BFC-4AE3-A4E5-477416A16E24",
              "versionStartIncluding": "31.011",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:rockwellautomation:compact_guardlogix_5380:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "62414E65-73C7-4172-B7BF-F40A66AFBB90",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:rockwellautomation:compactlogix_5380_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "65D5D8EB-6A19-4849-988D-C3F65071B05F",
              "versionStartIncluding": "31.011",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:rockwellautomation:compactlogix_5380:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "EDD040ED-B44C-47D0-B4D4-729C378C4F68",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "An unauthorized user could use a specially crafted sequence of Ethernet/IP messages, combined with heavy traffic \nloading to cause a denial-of-service condition in Rockwell Automation Logix controllers resulting in a major non-recoverable fault. If the target device becomes unavailable, a user would have to clear the fault and redownload \nthe user project file to bring the device back online and continue normal operation.\n\n\n"
    },
    {
      "lang": "es",
      "value": "Un usuario no autorizado podr\u00eda utilizar una secuencia especialmente manipulada de mensajes Ethernet/IP, combinada con una gran carga de tr\u00e1fico, para provocar una condici\u00f3n de Denegaci\u00f3n de Servicio (DoS) en los controladores Logix de Rockwell Automation, lo que provocar\u00eda una falla importante no recuperable. Si el dispositivo de destino deja de estar disponible, el usuario tendr\u00eda que borrar la falla y volver a descargar el archivo de proyecto del usuario para volver a poner el dispositivo en l\u00ednea y continuar con el funcionamiento normal."
    }
  ],
  "id": "CVE-2022-3752",
  "lastModified": "2026-06-17T05:00:14.520",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 8.6,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "NONE",
          "integrityImpact": "NONE",
          "privilegesRequired": "NONE",
          "scope": "CHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:N/I:N/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 4.0,
        "source": "PSIRT@rockwellautomation.com",
        "type": "Secondary"
      },
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 7.5,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "NONE",
          "integrityImpact": "NONE",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 3.6,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ],
    "ssvcV203": [
      {
        "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
        "ssvcData": {
          "id": "CVE-2022-3752",
          "options": [
            {
              "exploitation": "none"
            },
            {
              "automatable": "yes"
            },
            {
              "technicalImpact": "partial"
            }
          ],
          "role": "CISA Coordinator",
          "timestamp": "2025-04-16T14:27:21.670498Z",
          "version": "2.0.3"
        }
      }
    ]
  },
  "published": "2022-12-19T23:15:10.660",
  "references": [
    {
      "source": "PSIRT@rockwellautomation.com",
      "tags": [
        "Permissions Required",
        "Vendor Advisory"
      ],
      "url": "https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1137664"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Permissions Required",
        "Vendor Advisory"
      ],
      "url": "https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1137664"
    }
  ],
  "sourceIdentifier": "PSIRT@rockwellautomation.com",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-20"
        }
      ],
      "source": "PSIRT@rockwellautomation.com",
      "type": "Secondary"
    },
    {
      "description": [
        {
          "lang": "en",
          "value": "NVD-CWE-noinfo"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}



Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Drag nodes to arrange them. Double-click a related vulnerability to open it, or a source to visit its link. The Physics button on the left tunes the layout and the simulation; the legend at the bottom left hides or shows nodes by kind and by sighting type.

Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.

Sightings

Author Source Type Date Other

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Vulnerability timeline

Sightings and recorded dates, grouped by day · UTC

JSON
How durations are calculated

Following the VTEM framework (Black Hat USA 2015), time to patch starts when the vendor or a coordinator was informed, total time to patch at discovery, and disclosure to patch at public disclosure; vendor response time runs from the report to its acknowledgement. Time to exploit and time unpatched start at the earliest discovery or report, falling back to public disclosure. Unpatched time ends at the first recorded patch, or the calculation time when no patch is recorded. Exploitation to patch shows the interval between those two events; a published proof of concept is a public exploit, not exploitation.

Each result shows its source dates. A negative interval means the end event came first; when date-only inputs leave the order open, the result says so. Date-only inputs are approximate. The earliest evidence wins: KEV report dates and sightings are labelled as such. Records describing another vulnerability are listed but never calculated from, and a PoC alone does not establish exploitation. Missing patch evidence does not prove that no patch exists. Filters below change the event list only.

Events included in the timeline

Loading timeline…


    Loading…

    Loading…

    Loading…

    Related by attack behaviour

    Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.