FKIE_CVE-2022-35874

Vulnerability from fkie_nvd - Published: 2022-10-25 17:15 - Updated: 2024-11-21 07:11
Severity ?
Summary
Four format string injection vulnerabilities exist in the XCMD testWifiAP functionality of Abode Systems, Inc. iota All-In-One Security Kit 6.9X and 6.9Z. Specially-crafted configuration values can lead to memory corruption, information disclosure and denial of service. An attacker can modify a configuration value and then execute an XCMD to trigger these vulnerabilities.This vulnerability arises from format string injection via the `ssid` and `ssid_hex` configuration parameters, as used within the `testWifiAP` XCMD handler
References

{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:goabode:iota_all-in-one_security_kit_firmware:6.9x:*:*:*:*:*:*:*",
              "matchCriteriaId": "9341C371-6AC1-428C-809E-7856975E8FC3",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:goabode:iota_all-in-one_security_kit_firmware:6.9z:*:*:*:*:*:*:*",
              "matchCriteriaId": "EA9202A4-4D07-4293-93EE-73183AEEE5E0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "Four format string injection vulnerabilities exist in the XCMD testWifiAP functionality of Abode Systems, Inc. iota All-In-One Security Kit 6.9X and 6.9Z. Specially-crafted configuration values can lead to memory corruption, information disclosure and denial of service. An attacker can modify a configuration value and then execute an XCMD to trigger these vulnerabilities.This vulnerability arises from format string injection via the `ssid` and `ssid_hex` configuration parameters, as used within the `testWifiAP` XCMD handler"
    },
    {
      "lang": "es",
      "value": "Se presentan cuatro vulnerabilidades de inyecci\u00f3n de cadenas de formato en la funcionalidad XCMD testWifiAP de Abode Systems, Inc. iota All-In-One Security Kit versiones 6.9X y 6.9Z. Los valores de configuraci\u00f3n especialmente dise\u00f1ados pueden conllevar a una corrupci\u00f3n de la memoria, una divulgaci\u00f3n de informaci\u00f3n y una denegaci\u00f3n de servicio. Un atacante puede modificar un valor de configuraci\u00f3n y luego ejecutar un XCMD para desencadenar estas vulnerabilidades. Esta vulnerabilidad surge de una inyecci\u00f3n de cadenas de formato por medio de los par\u00e1metros de configuraci\u00f3n \"ssid\" y \"ssid_hex\", tal como son usadas dentro del manejador XCMD \"testWifiAP\""
    }
  ],
  "id": "CVE-2022-35874",
  "lastModified": "2024-11-21T07:11:51.400",
  "metrics": {
    "cvssMetricV30": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 8.2,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "NONE",
          "integrityImpact": "LOW",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:H",
          "version": "3.0"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 4.2,
        "source": "talos-cna@cisco.com",
        "type": "Secondary"
      }
    ],
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 9.8,
          "baseSeverity": "CRITICAL",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 5.9,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2022-10-25T17:15:54.510",
  "references": [
    {
      "source": "talos-cna@cisco.com",
      "tags": [
        "Exploit",
        "Technical Description",
        "Third Party Advisory"
      ],
      "url": "https://talosintelligence.com/vulnerability_reports/TALOS-2022-1581"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Exploit",
        "Technical Description",
        "Third Party Advisory"
      ],
      "url": "https://talosintelligence.com/vulnerability_reports/TALOS-2022-1581"
    }
  ],
  "sourceIdentifier": "talos-cna@cisco.com",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-134"
        }
      ],
      "source": "talos-cna@cisco.com",
      "type": "Secondary"
    }
  ]
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.