FKIE_CVE-2021-20990

Vulnerability from fkie_nvd - Published: 2021-04-19 14:15 - Updated: 2024-11-21 05:47
Summary
In Fibaro Home Center 2 and Lite devices with firmware version 4.600 and older an internal management service is accessible on port 8000 and some API endpoints could be accessed without authentication to trigger a shutdown, a reboot or a reboot into recovery mode.

{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:fibaro:home_center_2_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "867FAF63-0352-4AC8-AB9D-1FDEC2E942D4",
              "versionEndIncluding": "4.600",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:fibaro:home_center_2:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "8021D17B-DD82-46D0-AE92-372649467F1F",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:fibaro:home_center_lite_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "A06A908C-D871-46DA-AC42-63FF1518A558",
              "versionEndIncluding": "4.600",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:fibaro:home_center_lite:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "6A19AFCC-B670-450C-8B64-7770C86B4692",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "In Fibaro Home Center 2 and Lite devices with firmware version 4.600 and older an internal management service is accessible on port 8000 and some API endpoints could be accessed without authentication to trigger a shutdown, a reboot or a reboot into recovery mode."
    },
    {
      "lang": "es",
      "value": "En los dispositivos Fibaro Home Center versi\u00f3n 2 y Lite con versiones de firmware 4.600 y anteriores, un servicio de administraci\u00f3n interno es accesible en el puerto 8000 y algunos endpoints de la API pueden ser accedidos sin autenticaci\u00f3n para desencadenar un apagado, un reinicio o un reinicio en modo de recuperaci\u00f3n"
    }
  ],
  "id": "CVE-2021-20990",
  "lastModified": "2024-11-21T05:47:20.700",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "HIGH",
        "cvssData": {
          "accessComplexity": "LOW",
          "accessVector": "NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "COMPLETE",
          "baseScore": 7.8,
          "confidentialityImpact": "NONE",
          "integrityImpact": "NONE",
          "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C",
          "version": "2.0"
        },
        "exploitabilityScore": 10.0,
        "impactScore": 6.9,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 7.5,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "NONE",
          "integrityImpact": "NONE",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 3.6,
        "source": "info@cert.vde.com",
        "type": "Secondary"
      },
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 7.5,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "NONE",
          "integrityImpact": "NONE",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 3.6,
        "source": "nvd@nist.gov",
        "type": "Secondary"
      }
    ]
  },
  "published": "2021-04-19T14:15:11.710",
  "references": [
    {
      "source": "info@cert.vde.com",
      "tags": [
        "Exploit",
        "Third Party Advisory",
        "VDB Entry"
      ],
      "url": "http://packetstormsecurity.com/files/162243/Fibaro-Home-Center-MITM-Missing-Authentication-Code-Execution.html"
    },
    {
      "source": "info@cert.vde.com",
      "tags": [
        "Mailing List",
        "Third Party Advisory"
      ],
      "url": "http://seclists.org/fulldisclosure/2021/Apr/27"
    },
    {
      "source": "info@cert.vde.com",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "url": "https://www.iot-inspector.com/blog/advisory-fibaro-home-center/"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Exploit",
        "Third Party Advisory",
        "VDB Entry"
      ],
      "url": "http://packetstormsecurity.com/files/162243/Fibaro-Home-Center-MITM-Missing-Authentication-Code-Execution.html"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Mailing List",
        "Third Party Advisory"
      ],
      "url": "http://seclists.org/fulldisclosure/2021/Apr/27"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "url": "https://www.iot-inspector.com/blog/advisory-fibaro-home-center/"
    }
  ],
  "sourceIdentifier": "info@cert.vde.com",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-306"
        }
      ],
      "source": "info@cert.vde.com",
      "type": "Secondary"
    },
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-306"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Secondary"
    }
  ]
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…
Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.

Sightings

Author Source Type Date Other

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.


Loading…

Detection rules are retrieved from Rulezet.

Loading…

Loading…