FKIE_CVE-2020-27263
Vulnerability from fkie_nvd - Published: 2021-01-14 00:15 - Updated: 2026-06-17 03:09
Severity
Summary
KEPServerEX: v6.0 to v6.9, ThingWorx Kepware Server: v6.8 and v6.9, ThingWorx Industrial Connectivity: All versions, OPC-Aggregator: All versions, Rockwell Automation KEPServer Enterprise, GE Digital Industrial Gateway Server: v7.68.804 and v7.66, Software Toolbox TOP Server: All 6.x versions, are vulnerable to a heap-based buffer overflow. Opening a specifically crafted OPC UA message could allow an attacker to crash the server and potentially leak data.
References
| URL | Tags | ||
|---|---|---|---|
| ics-cert@hq.dhs.gov | https://us-cert.cisa.gov/ics/advisories/icsa-20-352-02 | Third Party Advisory, US Government Resource | |
| af854a3a-2127-422b-91ae-364da2661108 | https://us-cert.cisa.gov/ics/advisories/icsa-20-352-02 | Third Party Advisory, US Government Resource |
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| ge | industrial_gateway_server | 7.66 | |
| ge | industrial_gateway_server | 7.68.804 | |
| ptc | kepware_kepserverex | 6.0 | |
| ptc | kepware_kepserverex | 6.9 | |
| ptc | opc-aggregator | - | |
| ptc | thingworx_industrial_connectivity | - | |
| ptc | thingworx_kepware_server | 6.8 | |
| ptc | thingworx_kepware_server | 6.9 | |
| rockwellautomation | kepserver_enterprise | 6.6.504.0 | |
| rockwellautomation | kepserver_enterprise | 6.9.572.0 | |
| softwaretoolbox | top_server | * |
{
"affected": [
{
"affectedData": [
{
"product": "PTC Kepware KEPServerEX",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "v6.0 to v6.9"
}
]
},
{
"product": "ThingWorx Kepware Server",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "v6.8 and v6.9"
}
]
},
{
"product": "ThingWorx Industrial Connectivity",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"product": "OPC-Aggregator",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"product": "Rockwell Automation KEPServer Enterprise",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"product": "GE Digital Industrial Gateway Server",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "v7.68.804"
},
{
"status": "affected",
"version": "v7.66"
}
]
},
{
"product": "Software Toolbox TOP Server",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "All 6.x versions"
}
]
}
],
"source": "ics-cert@hq.dhs.gov"
}
],
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:ge:industrial_gateway_server:7.66:*:*:*:*:*:*:*",
"matchCriteriaId": "E5AEAC75-5E69-4C49-8D57-35401400C9D2",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:ge:industrial_gateway_server:7.68.804:*:*:*:*:*:*:*",
"matchCriteriaId": "906B1D62-7656-457E-B528-B0407C9D0BA4",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:ptc:kepware_kepserverex:6.0:*:*:*:*:*:*:*",
"matchCriteriaId": "6994DBB6-BA65-4E47-B0E4-42310120FC04",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:ptc:kepware_kepserverex:6.9:*:*:*:*:*:*:*",
"matchCriteriaId": "FC1720A3-85F1-4A85-B226-1CCBB34FCAAC",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:ptc:opc-aggregator:-:*:*:*:*:*:*:*",
"matchCriteriaId": "D8F46490-09F7-488A-B1EB-2286BFA0F882",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:ptc:thingworx_industrial_connectivity:-:*:*:*:*:*:*:*",
"matchCriteriaId": "D01A814D-8F2B-4B88-A66B-F2A2C293A6AB",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:ptc:thingworx_kepware_server:6.8:*:*:*:*:*:*:*",
"matchCriteriaId": "2DE510A4-1D91-447E-BF61-6CDFDFF82796",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:ptc:thingworx_kepware_server:6.9:*:*:*:*:*:*:*",
"matchCriteriaId": "2F16FBD0-8841-4E42-8FE6-796F7B4E5C16",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:rockwellautomation:kepserver_enterprise:6.6.504.0:*:*:*:*:*:*:*",
"matchCriteriaId": "6FFA2B21-E36C-41CE-B633-B831C6D42962",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:rockwellautomation:kepserver_enterprise:6.9.572.0:*:*:*:*:*:*:*",
"matchCriteriaId": "BACC2F09-9EC8-420A-B499-BF7CD737A473",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:softwaretoolbox:top_server:*:*:*:*:*:*:*:*",
"matchCriteriaId": "95B527BB-A27F-4080-8BBB-3FCA2408B7AE",
"versionEndIncluding": "6.9",
"versionStartIncluding": "6.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "KEPServerEX: v6.0 to v6.9, ThingWorx Kepware Server: v6.8 and v6.9, ThingWorx Industrial Connectivity: All versions, OPC-Aggregator: All versions, Rockwell Automation KEPServer Enterprise, GE Digital Industrial Gateway Server: v7.68.804 and v7.66, Software Toolbox TOP Server: All 6.x versions, are vulnerable to a heap-based buffer overflow. Opening a specifically crafted OPC UA message could allow an attacker to crash the server and potentially leak data."
},
{
"lang": "es",
"value": "KEPServerEX: versiones v6.0 hasta v6.9, ThingWorx Kepware Server: versiones v6.8 y v6.9, ThingWorx Industrial Connectivity: Todas las versiones, OPC-Aggregator: Todas las versiones, Rockwell Automation KEPServer Enterprise, GE Digital Industrial Gateway Server: versiones v7.68.804 y v7.66, Software Toolbox TOP Server: Todas las versiones 6.x son vulnerables a un desbordamiento de b\u00fafer en la regi\u00f3n heap de la memoria.\u0026#xa0;Abrir un mensaje OPC UA espec\u00edficamente dise\u00f1ado podr\u00eda permitir a un atacante bloquear el servidor y potencialmente filtrar datos"
}
],
"id": "CVE-2020-27263",
"lastModified": "2026-06-17T03:09:04.717",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "MEDIUM",
"cvssData": {
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"availabilityImpact": "PARTIAL",
"baseScore": 6.4,
"confidentialityImpact": "PARTIAL",
"integrityImpact": "NONE",
"vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:P",
"version": "2.0"
},
"exploitabilityScore": 10.0,
"impactScore": 4.9,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "nvd@nist.gov",
"type": "Primary",
"userInteractionRequired": false
}
],
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.1,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:H",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 5.2,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2021-01-14T00:15:13.353",
"references": [
{
"source": "ics-cert@hq.dhs.gov",
"tags": [
"Third Party Advisory",
"US Government Resource"
],
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-352-02"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Third Party Advisory",
"US Government Resource"
],
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-352-02"
}
],
"sourceIdentifier": "ics-cert@hq.dhs.gov",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-122"
}
],
"source": "ics-cert@hq.dhs.gov",
"type": "Secondary"
},
{
"description": [
{
"lang": "en",
"value": "CWE-787"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
Loading…
Loading…
Drag nodes to arrange them. Double-click a related vulnerability to open it, or a source to visit its link. The Physics button on the left tunes the layout and the simulation; the legend at the bottom left hides or shows nodes by kind and by sighting type.
Experimental. This forecast is provided for visualization only and may change without notice. Do not use it for operational decisions.
Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.
Sightings
| Author | Source | Type | Date | Other |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Vulnerability timeline
Sightings and recorded dates, grouped by day · UTC
Loading timeline…
Loading…
Loading…
The MITRE ATT&CK techniques below are AI-generated suggestions, inferred from the description of the
vulnerability by the CIRCL/vulnerability-attack-technique-classification-roberta-base
model, served locally by ML-Gateway.
They have not been verified by an analyst and are provided for guidance only.
The approach is described in our paper Mapping CVEs to MITRE ATT&CK Techniques: A Curated Gold-Set Classifier and the Limits of LLM-Assisted Label Expansion.
Browse all ATT&CK techniques and the vulnerabilities related to each.
The approach is described in our paper Mapping CVEs to MITRE ATT&CK Techniques: A Curated Gold-Set Classifier and the Limits of LLM-Assisted Label Expansion.
Browse all ATT&CK techniques and the vulnerabilities related to each.
Loading…
Related by attack behaviour
Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.