FKIE_CVE-2020-26907
Vulnerability from fkie_nvd - Published: 2020-10-09 07:15 - Updated: 2024-11-21 05:20
Severity ?
9.6 (Critical) - CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H
8.8 (High) - CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
8.8 (High) - CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Summary
Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects RBK852 before 3.2.16.6, RBR850 before 3.2.16.6, and RBS850 before 3.2.16.6.
References
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| netgear | rbk852_firmware | * | |
| netgear | rbk852 | - | |
| netgear | rbr850_firmware | * | |
| netgear | rbr850 | - | |
| netgear | rbs850_firmware | * | |
| netgear | rbs850 | - |
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "B66A716A-7EC5-4F9B-853A-36C0D1AA3BFE",
"versionEndExcluding": "3.2.16.6",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*",
"matchCriteriaId": "14F257FE-31CE-4F74-829D-29407D74ADF7",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "FE13548D-0A26-45C1-8424-D4705EB105EA",
"versionEndExcluding": "3.2.16.6",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*",
"matchCriteriaId": "D92E4C8E-222A-476C-8273-F7171FC61F0B",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "041D94DE-78C9-475C-9FAE-0B081C69B55F",
"versionEndExcluding": "3.2.16.6",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*",
"matchCriteriaId": "221CA950-E984-44CD-9E1B-3AADE3CEBE52",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects RBK852 before 3.2.16.6, RBR850 before 3.2.16.6, and RBS850 before 3.2.16.6."
},
{
"lang": "es",
"value": "Determinados dispositivos NETGEAR, est\u00e1n afectados por una inyecci\u00f3n de comandos por parte de un atacante no autenticado.\u0026#xa0;Esto afecta a RBK852 versiones anteriores a 3.2.16.6, RBR850 versiones anteriores a 3.2.16.6 y RBS850 versiones anteriores a 3.2.16.6"
}
],
"id": "CVE-2020-26907",
"lastModified": "2024-11-21T05:20:27.897",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "HIGH",
"cvssData": {
"accessComplexity": "LOW",
"accessVector": "ADJACENT_NETWORK",
"authentication": "SINGLE",
"availabilityImpact": "COMPLETE",
"baseScore": 7.7,
"confidentialityImpact": "COMPLETE",
"integrityImpact": "COMPLETE",
"vectorString": "AV:A/AC:L/Au:S/C:C/I:C/A:C",
"version": "2.0"
},
"exploitabilityScore": 5.1,
"impactScore": 10.0,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "nvd@nist.gov",
"type": "Primary",
"userInteractionRequired": false
}
],
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.6,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 2.8,
"impactScore": 6.0,
"source": "cve@mitre.org",
"type": "Secondary"
},
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 2.8,
"impactScore": 5.9,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2020-10-09T07:15:16.653",
"references": [
{
"source": "cve@mitre.org",
"tags": [
"Vendor Advisory"
],
"url": "https://kb.netgear.com/000062347/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0264"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Vendor Advisory"
],
"url": "https://kb.netgear.com/000062347/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0264"
}
],
"sourceIdentifier": "cve@mitre.org",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-77"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…
Loading…