FKIE_CVE-2020-25749

Vulnerability from fkie_nvd - Published: 2020-09-25 04:23 - Updated: 2026-06-17 03:07
Summary
The Telnet service of Rubetek cameras RV-3406, RV-3409, and RV-3411 cameras (firmware versions v342, v339) could allow an remote attacker to take full control of the device with a high-privileged account. The vulnerability exists because a system account has a default and static password. The Telnet service cannot be disabled and this password cannot be changed via standard functionality.

{
  "affected": [
    {
      "affectedData": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "source": "cve@mitre.org"
    }
  ],
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:rubetek:rv-3406_firmware:339:*:*:*:*:*:*:*",
              "matchCriteriaId": "57AF1900-5D42-45B9-9906-B1EBC933A064",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:rubetek:rv-3406_firmware:342:*:*:*:*:*:*:*",
              "matchCriteriaId": "72F51EDA-EA7A-4E58-A071-A0D6F3AEC379",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:rubetek:rv-3406:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "D0C29138-1CBA-4677-B494-AA5278632606",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:rubetek:rv-3409_firmware:339:*:*:*:*:*:*:*",
              "matchCriteriaId": "B2BD4E56-46E1-4985-A46F-C9B4A374A17F",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:rubetek:rv-3409_firmware:342:*:*:*:*:*:*:*",
              "matchCriteriaId": "EE539B49-BF73-4411-855D-69E02E6AD917",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:rubetek:rv-3409:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "93B04FD1-8EEF-4DDC-83A9-9F5390378D28",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:rubetek:rv-3411_firmware:339:*:*:*:*:*:*:*",
              "matchCriteriaId": "183C8C01-1F30-40F5-BD9F-6D217EB1CD42",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:rubetek:rv-3411_firmware:342:*:*:*:*:*:*:*",
              "matchCriteriaId": "C9ECA3AF-D4F0-4F8B-854C-0C63BB090E44",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:rubetek:rv-3411:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "0D54B518-140F-4933-A1C8-45A0A7B3F167",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "The Telnet service of Rubetek cameras RV-3406, RV-3409, and RV-3411 cameras (firmware versions v342, v339) could allow an remote attacker to take full control of the device with a high-privileged account. The vulnerability exists because a system account has a default and static password. The Telnet service cannot be disabled and this password cannot be changed via standard functionality."
    },
    {
      "lang": "es",
      "value": "El servicio Telnet de las c\u00e1maras RV-3406, RV-3409 y RV-3411 de Rubetek (versiones de firmware v342, v339), podr\u00eda permitir a un atacante remoto tomar el control total del dispositivo con una cuenta muy privilegiada.\u0026#xa0;La vulnerabilidad se presenta porque una cuenta del sistema posee una contrase\u00f1a predeterminada y est\u00e1tica.\u0026#xa0;El servicio Telnet no puede ser desactivado y esta contrase\u00f1a no puede ser cambiada por medio de la funcionalidad est\u00e1ndar"
    }
  ],
  "id": "CVE-2020-25749",
  "lastModified": "2026-06-17T03:07:14.210",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "HIGH",
        "cvssData": {
          "accessComplexity": "LOW",
          "accessVector": "NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "COMPLETE",
          "baseScore": 10.0,
          "confidentialityImpact": "COMPLETE",
          "integrityImpact": "COMPLETE",
          "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
          "version": "2.0"
        },
        "exploitabilityScore": 10.0,
        "impactScore": 10.0,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 9.8,
          "baseSeverity": "CRITICAL",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 5.9,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2020-09-25T04:23:05.167",
  "references": [
    {
      "source": "cve@mitre.org",
      "tags": [
        "Third Party Advisory"
      ],
      "url": "https://github.com/jet-pentest/CVE-2020-25749"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory"
      ],
      "url": "https://github.com/jet-pentest/CVE-2020-25749"
    }
  ],
  "sourceIdentifier": "cve@mitre.org",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-798"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.

Sightings

Author Source Type Date Other

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.

Loading…

Detection rules are retrieved from Rulezet.

Loading…

Loading…