FKIE_CVE-2020-24552

Vulnerability from fkie_nvd - Published: 2020-09-10 09:15 - Updated: 2026-06-17 03:05
Summary
Atop Technology industrial 3G/4G gateway contains Command Injection vulnerability. Due to insufficient input validation, the device's web management interface allows attackers to inject specific code and execute system commands without privilege.

{
  "affected": [
    {
      "affectedData": [
        {
          "product": "3G/4G LTE Cellular to Ethernet and Serial Secure Industrial Gateway SE5901",
          "vendor": "Atop Technology",
          "versions": [
            {
              "lessThanOrEqual": "1.4",
              "status": "affected",
              "version": "1.18",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "3G/4G LTE Cellular to Ethernet and Serial Secure Industrial Gateway SE5901B",
          "vendor": "Atop Technology",
          "versions": [
            {
              "lessThanOrEqual": "1.4",
              "status": "affected",
              "version": "1.18",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "3G/4G LTE Cellular to Ethernet and Serial Secure Industrial Gateway SE5904D",
          "vendor": "Atop Technology",
          "versions": [
            {
              "lessThanOrEqual": "1.4",
              "status": "affected",
              "version": "1.18",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "3G/4G LTE Cellular to Ethernet and Serial Secure Industrial Gateway SE5908",
          "vendor": "Atop Technology",
          "versions": [
            {
              "status": "affected",
              "version": "1.18 1.4"
            }
          ]
        },
        {
          "product": "3G/4G LTE Cellular to Ethernet and Serial Secure Industrial Gateway SE5908A",
          "vendor": "Atop Technology",
          "versions": [
            {
              "status": "affected",
              "version": "1.18 1.4"
            }
          ]
        },
        {
          "product": "3G/4G LTE Cellular to Ethernet and Serial Secure Industrial Gateway SE5916",
          "vendor": "Atop Technology",
          "versions": [
            {
              "status": "affected",
              "version": "1.18 1.4"
            }
          ]
        },
        {
          "product": "3G/4G LTE Cellular to Ethernet and Serial Secure Industrial Gateway SE5916A",
          "vendor": "Atop Technology",
          "versions": [
            {
              "status": "affected",
              "version": "1.18 1.4"
            }
          ]
        }
      ],
      "source": "twcert@cert.org.tw"
    }
  ],
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:atoptechnology:se5901_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "C5918207-0E49-459D-8B9D-C0DC044DE48F",
              "versionEndIncluding": "1.40",
              "versionStartIncluding": "1.18",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:atoptechnology:se5901:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "C79C9A6A-E292-403E-AE7C-8585BF9DF9BF",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:atoptechnology:se5901b_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "E196C85A-DD61-4AD3-9B3A-606ECD790272",
              "versionEndIncluding": "1.40",
              "versionStartIncluding": "1.18",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:atoptechnology:se5901b:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "F005E3ED-A937-4E22-B7E5-A19D75BFF19E",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:atoptechnology:se5904d_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "04A2905F-6CB6-4034-91D4-31C35B818D6D",
              "versionEndIncluding": "1.40",
              "versionStartIncluding": "1.18",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:atoptechnology:se5904d:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "993B0A78-9EF4-4CE3-97BE-83A8E5268DB9",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:atoptechnology:se5908_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "FD9F05F1-E912-4886-9FE8-B41D7B2D9329",
              "versionEndIncluding": "1.40",
              "versionStartIncluding": "1.18",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:atoptechnology:se5908:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "B0A57F74-32C6-45E0-BFE0-27B3FE96AA80",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:atoptechnology:se5908a_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "9465E477-471B-4AD5-B997-5A767E87EF93",
              "versionEndIncluding": "1.40",
              "versionStartIncluding": "1.18",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:atoptechnology:se5908a:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "3BDA1AE5-5098-4B1F-B4FD-29F9935DF6E9",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:atoptechnology:se5916_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "EE19B5D8-FBCD-4EAE-9A6B-B50E2742146C",
              "versionEndIncluding": "1.40",
              "versionStartIncluding": "1.18",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:atoptechnology:se5916:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "61C8BC8B-F1F8-4A96-85AB-820101AA570A",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:atoptechnology:se5916a_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "4E2EBD60-4323-4AAB-ABBA-DC4BCD717294",
              "versionEndIncluding": "1.40",
              "versionStartIncluding": "1.18",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:atoptechnology:se5916a:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "2D66FC6D-D307-4BA0-9807-D16C67203053",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "Atop Technology industrial 3G/4G gateway contains Command Injection vulnerability. Due to insufficient input validation, the device\u0027s web management interface allows attackers to inject specific code and execute system commands without privilege."
    },
    {
      "lang": "es",
      "value": "Una puerta de enlace industrial 3G/4G de Atop Technology contiene una vulnerabilidad de Inyecci\u00f3n de Comando. Debido a una comprobaci\u00f3n de entrada insuficiente, la interfaz de administraci\u00f3n web del dispositivo permite a atacantes inyectar c\u00f3digo espec\u00edfico y ejecutar comandos del sistema sin privilegios"
    }
  ],
  "id": "CVE-2020-24552",
  "lastModified": "2026-06-17T03:05:44.917",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "HIGH",
        "cvssData": {
          "accessComplexity": "LOW",
          "accessVector": "NETWORK",
          "authentication": "SINGLE",
          "availabilityImpact": "COMPLETE",
          "baseScore": 9.0,
          "confidentialityImpact": "COMPLETE",
          "integrityImpact": "COMPLETE",
          "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
          "version": "2.0"
        },
        "exploitabilityScore": 8.0,
        "impactScore": 10.0,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "NONE",
          "baseScore": 5.5,
          "baseSeverity": "MEDIUM",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "LOW",
          "privilegesRequired": "HIGH",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:L/A:N",
          "version": "3.1"
        },
        "exploitabilityScore": 1.2,
        "impactScore": 4.2,
        "source": "twcert@cert.org.tw",
        "type": "Secondary"
      },
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 7.2,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "HIGH",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 1.2,
        "impactScore": 5.9,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2020-09-10T09:15:12.097",
  "references": [
    {
      "source": "twcert@cert.org.tw",
      "tags": [
        "Third Party Advisory"
      ],
      "url": "https://www.twcert.org.tw/tw/cp-132-3956-608f1-1.html"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory"
      ],
      "url": "https://www.twcert.org.tw/tw/cp-132-3956-608f1-1.html"
    }
  ],
  "sourceIdentifier": "twcert@cert.org.tw",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-78"
        }
      ],
      "source": "twcert@cert.org.tw",
      "type": "Secondary"
    },
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-78"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}



Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.

Sightings

Author Source Type Date Other

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.

Loading…

Loading…

Loading…

Related by attack behaviour

Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.


Loading…