FKIE_CVE-2019-6183

Vulnerability from fkie_nvd - Published: 2019-12-10 18:15 - Updated: 2026-06-17 02:38
Summary
A denial of service vulnerability has been reported in Lenovo Energy Management Driver for Windows 10 versions prior to 15.11.29.7 that could cause systems to experience a blue screen error. Lenovo Energy Management is a client utility. Lenovo XClarity Energy Manager is not affected.
Impacted products
Vendor Product Version
lenovo energy_management *

{
  "affected": [
    {
      "affectedData": [
        {
          "product": "Energy Management driver",
          "vendor": "Lenovo",
          "versions": [
            {
              "lessThan": "15.11.29.7",
              "status": "affected",
              "version": "unspecified",
              "versionType": "custom"
            }
          ]
        }
      ],
      "source": "psirt@lenovo.com"
    }
  ],
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:lenovo:energy_management:*:*:*:*:*:windows:*:*",
              "matchCriteriaId": "9CA444C6-8BE9-4A65-A4D1-BD51D47B06BA",
              "versionEndExcluding": "15.11.29.7",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "A denial of service vulnerability has been reported in Lenovo Energy Management Driver for Windows 10 versions prior to 15.11.29.7 that could cause systems to experience a blue screen error. Lenovo Energy Management is a client utility. Lenovo XClarity Energy Manager is not affected."
    },
    {
      "lang": "es",
      "value": "Se report\u00f3 una vulnerabilidad de denegaci\u00f3n de servicio en Lenovo Energy Management Driver para Windows 10 versiones anteriores a 15.11.29.7, lo que podr\u00eda causar que los sistemas experimenten un error de pantalla azul. Lenovo Energy Management es una utilidad del cliente. Lenovo XClarity Energy Manager no est\u00e1 afectado."
    }
  ],
  "id": "CVE-2019-6183",
  "lastModified": "2026-06-17T02:38:45.370",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "HIGH",
        "cvssData": {
          "accessComplexity": "LOW",
          "accessVector": "NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "COMPLETE",
          "baseScore": 7.8,
          "confidentialityImpact": "NONE",
          "integrityImpact": "NONE",
          "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C",
          "version": "2.0"
        },
        "exploitabilityScore": 10.0,
        "impactScore": 6.9,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 7.5,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "NONE",
          "integrityImpact": "NONE",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 3.6,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2019-12-10T18:15:09.517",
  "references": [
    {
      "source": "psirt@lenovo.com",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://support.lenovo.com/solutions/LEN-27682"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://support.lenovo.com/solutions/LEN-27682"
    }
  ],
  "sourceIdentifier": "psirt@lenovo.com",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "NVD-CWE-noinfo"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}



Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.

Sightings

Author Source Type Date Other

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.

Loading…

Detection rules are retrieved from Rulezet.

Loading…

Loading…

Related by attack behaviour

Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.


Loading…