FKIE_CVE-2019-19632
Vulnerability from fkie_nvd - Published: 2020-01-24 15:15 - Updated: 2026-06-17 02:26
Severity
Summary
An issue was discovered in Big Switch Big Monitoring Fabric 6.2 through 6.2.4, 6.3 through 6.3.9, 7.0 through 7.0.3, and 7.1 through 7.1.3; Big Cloud Fabric 4.5 through 4.5.5, 4.7 through 4.7.7, 5.0 through 5.0.1, and 5.1 through 5.1.4; and Multi-Cloud Director through 1.1.0. An unauthenticated attacker may inject stored arbitrary JavaScript (XSS), and execute it in the content of authenticated administrators.
References
| URL | Tags | ||
|---|---|---|---|
| cve@mitre.org | https://know.bishopfox.com/advisories | Third Party Advisory | |
| cve@mitre.org | https://know.bishopfox.com/advisories/big-monitoring-fabric | Exploit, Third Party Advisory | |
| af854a3a-2127-422b-91ae-364da2661108 | https://know.bishopfox.com/advisories | Third Party Advisory | |
| af854a3a-2127-422b-91ae-364da2661108 | https://know.bishopfox.com/advisories/big-monitoring-fabric | Exploit, Third Party Advisory |
Impacted products
{
"affected": [
{
"affectedData": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"source": "cve@mitre.org"
}
],
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:bigswitch:big_cloud_fabric:*:*:*:*:*:*:*:*",
"matchCriteriaId": "78DBA99A-E2AA-4B6C-9514-1B95C7C14E00",
"versionEndExcluding": "4.5.5",
"versionStartIncluding": "4.5",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:bigswitch:big_cloud_fabric:*:*:*:*:*:*:*:*",
"matchCriteriaId": "D6B1226C-87F5-49FC-B872-3C73012C00A9",
"versionEndExcluding": "4.7.7",
"versionStartIncluding": "4.7",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:bigswitch:big_cloud_fabric:*:*:*:*:*:*:*:*",
"matchCriteriaId": "C7CFCAA3-06CF-45C4-8640-2A3A7E397EEB",
"versionEndExcluding": "5.0.1",
"versionStartIncluding": "5.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:bigswitch:big_cloud_fabric:*:*:*:*:*:*:*:*",
"matchCriteriaId": "982B590C-D8E6-42FE-B3EA-525B50DD2FCA",
"versionEndExcluding": "5.1.4",
"versionStartIncluding": "5.1",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:bigswitch:big_monitoring_fabric:*:*:*:*:*:*:*:*",
"matchCriteriaId": "83BF3591-006A-4A0C-AB50-90F9E1C97E3D",
"versionEndExcluding": "6.2.4",
"versionStartIncluding": "6.2",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:bigswitch:big_monitoring_fabric:*:*:*:*:*:*:*:*",
"matchCriteriaId": "9F7711F6-3AA6-4D49-9AF1-E6AE87552EC7",
"versionEndExcluding": "6.3.9",
"versionStartIncluding": "6.3",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:bigswitch:big_monitoring_fabric:*:*:*:*:*:*:*:*",
"matchCriteriaId": "391CBB0B-A0A0-491C-8F88-96EB89BCAD83",
"versionEndExcluding": "7.0.3",
"versionStartIncluding": "7.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:bigswitch:big_monitoring_fabric:*:*:*:*:*:*:*:*",
"matchCriteriaId": "1665CA5F-FDF1-409E-A36F-139EAF510D9A",
"versionEndExcluding": "7.1.4",
"versionStartIncluding": "7.1",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:bigswitch:multi-cloud_director:*:*:*:*:*:*:*:*",
"matchCriteriaId": "B0037D82-D099-42A7-BB95-A4F91DA0166E",
"versionEndExcluding": "1.1.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "An issue was discovered in Big Switch Big Monitoring Fabric 6.2 through 6.2.4, 6.3 through 6.3.9, 7.0 through 7.0.3, and 7.1 through 7.1.3; Big Cloud Fabric 4.5 through 4.5.5, 4.7 through 4.7.7, 5.0 through 5.0.1, and 5.1 through 5.1.4; and Multi-Cloud Director through 1.1.0. An unauthenticated attacker may inject stored arbitrary JavaScript (XSS), and execute it in the content of authenticated administrators."
},
{
"lang": "es",
"value": "Se detect\u00f3 un problema en Big Switch Big Monitoring Fabric versiones 6.2 hasta 6.2.4, 6.3 hasta 6.3.9, 7.0 hasta 7.0.3 y 7.1 hasta 7.1.3; Big Cloud Fabric versiones 4.5 hasta 4.5.5, 4.7 hasta 4.7.7, 5.0 hasta 5.0.1 y 5.1 hasta 5.1.4; y Director Multi-Cloud versiones hasta 1.1.0. Un atacante no autenticado puede inyectar JavaScript (XSS) arbitrario almacenado y ejecutarlo en el contenido de administradores autenticados."
}
],
"id": "CVE-2019-19632",
"lastModified": "2026-06-17T02:26:58.863",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "MEDIUM",
"cvssData": {
"accessComplexity": "MEDIUM",
"accessVector": "NETWORK",
"authentication": "NONE",
"availabilityImpact": "NONE",
"baseScore": 4.3,
"confidentialityImpact": "NONE",
"integrityImpact": "PARTIAL",
"vectorString": "AV:N/AC:M/Au:N/C:N/I:P/A:N",
"version": "2.0"
},
"exploitabilityScore": 8.6,
"impactScore": 2.9,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "nvd@nist.gov",
"type": "Primary",
"userInteractionRequired": true
}
],
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 6.1,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"privilegesRequired": "NONE",
"scope": "CHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N",
"version": "3.1"
},
"exploitabilityScore": 2.8,
"impactScore": 2.7,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2020-01-24T15:15:13.623",
"references": [
{
"source": "cve@mitre.org",
"tags": [
"Third Party Advisory"
],
"url": "https://know.bishopfox.com/advisories"
},
{
"source": "cve@mitre.org",
"tags": [
"Exploit",
"Third Party Advisory"
],
"url": "https://know.bishopfox.com/advisories/big-monitoring-fabric"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Third Party Advisory"
],
"url": "https://know.bishopfox.com/advisories"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Exploit",
"Third Party Advisory"
],
"url": "https://know.bishopfox.com/advisories/big-monitoring-fabric"
}
],
"sourceIdentifier": "cve@mitre.org",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-79"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
Loading…
Loading…
Experimental. This forecast is provided for visualization only and may change without notice. Do not use it for operational decisions.
Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.
Sightings
| Author | Source | Type | Date | Other |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…
Loading…