FKIE_CVE-2019-11536

Vulnerability from fkie_nvd - Published: 2019-05-22 18:29 - Updated: 2024-11-21 04:21
Summary
Kalki Kalkitech SYNC3000 Substation DCU GPC v2.22.6, 2.23.0, 2.24.0, 3.0.0, 3.1.0, 3.1.16, 3.2.3, 3.2.6, 3.5.0, 3.6.0, and 3.6.1, when WebHMI is not installed, allows an attacker to inject client-side commands or scripts to be executed on the device with privileged access, aka CYB/2019/19561. The attack requires network connectivity to the device and exploits the webserver interface, typically through a browser.

{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:kalkitech:sync3000_firmware:2.22.6:*:*:*:*:*:*:*",
              "matchCriteriaId": "DCB00F5A-F9D5-41E8-877E-92CDA8308560",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:kalkitech:sync3000_firmware:2.23.0:*:*:*:*:*:*:*",
              "matchCriteriaId": "C5FF6A57-74BE-47B5-87C3-6D9446D4BA4F",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:kalkitech:sync3000_firmware:2.24.0:*:*:*:*:*:*:*",
              "matchCriteriaId": "F2B79022-7CF7-4676-979D-AB5E1C284A1C",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:kalkitech:sync3000_firmware:3.0.0:*:*:*:*:*:*:*",
              "matchCriteriaId": "B61F7362-90D4-4A9E-9816-DDEA136A81C7",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:kalkitech:sync3000_firmware:3.1.0:*:*:*:*:*:*:*",
              "matchCriteriaId": "EC382AB4-76BF-4EB7-8926-A30C1EB628C9",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:kalkitech:sync3000_firmware:3.1.16:*:*:*:*:*:*:*",
              "matchCriteriaId": "2F6FC17B-061B-41BF-8681-D598486A1DE4",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:kalkitech:sync3000_firmware:3.2.3:*:*:*:*:*:*:*",
              "matchCriteriaId": "2FF26B0C-70F8-45D6-BF58-482CD5506663",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:kalkitech:sync3000_firmware:3.2.6:*:*:*:*:*:*:*",
              "matchCriteriaId": "B91FB77E-6830-4BD5-A082-3762AD4259DF",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:kalkitech:sync3000_firmware:3.5.0:*:*:*:*:*:*:*",
              "matchCriteriaId": "3C104E84-AFDD-4CF6-9407-E75419BFF78B",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:kalkitech:sync3000_firmware:3.6.0:*:*:*:*:*:*:*",
              "matchCriteriaId": "67A4FC87-0D08-46E9-B9A2-CA42B4FA0D6B",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:kalkitech:sync3000_firmware:3.6.1:*:*:*:*:*:*:*",
              "matchCriteriaId": "0617B24A-9FA0-46DE-8887-2113D387EC87",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:kalkitech:sync3000:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "D871456C-B80B-4D6B-93E0-4BD87F80141E",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "Kalki Kalkitech SYNC3000 Substation DCU GPC v2.22.6, 2.23.0, 2.24.0, 3.0.0, 3.1.0, 3.1.16, 3.2.3, 3.2.6, 3.5.0, 3.6.0, and 3.6.1, when WebHMI is not installed, allows an attacker to inject client-side commands or scripts to be executed on the device with privileged access, aka CYB/2019/19561. The attack requires network connectivity to the device and exploits the webserver interface, typically through a browser."
    },
    {
      "lang": "es",
      "value": "Kalki Kalkitech Subestaci\u00f3n SYNC3000 DCU GPC versiones 2.22.6, 2.23.0, 2.24.0, 3.0.0, 3.1.0, 3.1.16, 3.2.3, 3.2.6, 3.5.0, 3.6.0 y 3.6.1, cuando la WebHMI no est\u00e1 instalada, permite que un atacante inyecte comandos del lado del cliente  para que sean ejecutados en el dispositivo con acceso privilegiado, tambi\u00e9n conocido como CYB / 2019/19561. El ataque requiere de conectividad de red hacia el dispositivo y explota la interfaz webserver, generalmente por medio de un navegador."
    }
  ],
  "id": "CVE-2019-11536",
  "lastModified": "2024-11-21T04:21:17.520",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "HIGH",
        "cvssData": {
          "accessComplexity": "LOW",
          "accessVector": "NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "COMPLETE",
          "baseScore": 10.0,
          "confidentialityImpact": "COMPLETE",
          "integrityImpact": "COMPLETE",
          "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
          "version": "2.0"
        },
        "exploitabilityScore": 10.0,
        "impactScore": 10.0,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV30": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 9.8,
          "baseSeverity": "CRITICAL",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.0"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 5.9,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2019-05-22T18:29:00.537",
  "references": [
    {
      "source": "cve@mitre.org",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://www.kalkitech.com/cybersecurity/"
    },
    {
      "source": "cve@mitre.org",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://www.kalkitech.com/wp-content/uploads/CYB_19561_Advisory.pdf"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://www.kalkitech.com/cybersecurity/"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://www.kalkitech.com/wp-content/uploads/CYB_19561_Advisory.pdf"
    }
  ],
  "sourceIdentifier": "cve@mitre.org",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "NVD-CWE-noinfo"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.

Sightings

Author Source Type Date Other

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.

Loading…

Detection rules are retrieved from Rulezet.

Loading…

Loading…