FKIE_CVE-2018-8842
Vulnerability from fkie_nvd - Published: 2018-09-26 19:29 - Updated: 2026-06-17 02:05
Severity
Summary
Philips e-Alert Unit (non-medical device), Version R2.1 and prior. The software transmits sensitive or security-critical data in cleartext in a communication channel that can be sniffed by unauthorized actors. The Philips e-Alert communication channel is not encrypted which could therefore lead to disclosure of personal contact information and application login credentials from within the same subnet.
References
| URL | Tags | ||
|---|---|---|---|
| ics-cert@hq.dhs.gov | http://www.securityfocus.com/bid/105194 | Third Party Advisory, VDB Entry | |
| ics-cert@hq.dhs.gov | https://ics-cert.us-cert.gov/advisories/ICSA-18-242-01 | Mitigation, Third Party Advisory, US Government Resource | |
| ics-cert@hq.dhs.gov | https://www.usa.philips.com/healthcare/about/customer-support/product-security | Vendor Advisory | |
| af854a3a-2127-422b-91ae-364da2661108 | http://www.securityfocus.com/bid/105194 | Third Party Advisory, VDB Entry | |
| af854a3a-2127-422b-91ae-364da2661108 | https://ics-cert.us-cert.gov/advisories/ICSA-18-242-01 | Mitigation, Third Party Advisory, US Government Resource | |
| af854a3a-2127-422b-91ae-364da2661108 | https://www.usa.philips.com/healthcare/about/customer-support/product-security | Vendor Advisory |
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| philips | e-alert_firmware | * |
{
"affected": [
{
"affectedData": [
{
"product": "e-Alert Unit (non-medical device)",
"vendor": "Philips",
"versions": [
{
"status": "affected",
"version": "R2.1 and prior"
}
]
}
],
"source": "ics-cert@hq.dhs.gov"
}
],
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:philips:e-alert_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "A20F1AAF-D947-4713-AB4E-12364592DBA3",
"versionEndIncluding": "r2.1",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "Philips e-Alert Unit (non-medical device), Version R2.1 and prior. The software transmits sensitive or security-critical data in cleartext in a communication channel that can be sniffed by unauthorized actors. The Philips e-Alert communication channel is not encrypted which could therefore lead to disclosure of personal contact information and application login credentials from within the same subnet."
},
{
"lang": "es",
"value": "Philips e-Alert Unit (dispositivo no m\u00e9dico), versiones R2.1 y anteriores. El software transmite datos sensibles o cr\u00edticos para la seguridad en texto claro en un canal de comunicaci\u00f3n que puede ser rastreado por actores no autorizados. El canal de comunicaci\u00f3n de Philips e-Alert no est\u00e1 cifrado, lo que podr\u00eda conducir, por lo tanto, a la divulgaci\u00f3n de informaci\u00f3n personal de contacto y de las ccredenciales de inicio de sesi\u00f3n en la aplicaci\u00f3n desde dentro de la misma subred."
}
],
"id": "CVE-2018-8842",
"lastModified": "2026-06-17T02:05:29.570",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "LOW",
"cvssData": {
"accessComplexity": "LOW",
"accessVector": "ADJACENT_NETWORK",
"authentication": "NONE",
"availabilityImpact": "NONE",
"baseScore": 3.3,
"confidentialityImpact": "PARTIAL",
"integrityImpact": "NONE",
"vectorString": "AV:A/AC:L/Au:N/C:P/I:N/A:N",
"version": "2.0"
},
"exploitabilityScore": 6.5,
"impactScore": 2.9,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "nvd@nist.gov",
"type": "Primary",
"userInteractionRequired": false
}
],
"cvssMetricV30": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
},
"exploitabilityScore": 2.8,
"impactScore": 5.9,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2018-09-26T19:29:00.690",
"references": [
{
"source": "ics-cert@hq.dhs.gov",
"tags": [
"Third Party Advisory",
"VDB Entry"
],
"url": "http://www.securityfocus.com/bid/105194"
},
{
"source": "ics-cert@hq.dhs.gov",
"tags": [
"Mitigation",
"Third Party Advisory",
"US Government Resource"
],
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-242-01"
},
{
"source": "ics-cert@hq.dhs.gov",
"tags": [
"Vendor Advisory"
],
"url": "https://www.usa.philips.com/healthcare/about/customer-support/product-security"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Third Party Advisory",
"VDB Entry"
],
"url": "http://www.securityfocus.com/bid/105194"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Mitigation",
"Third Party Advisory",
"US Government Resource"
],
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-242-01"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Vendor Advisory"
],
"url": "https://www.usa.philips.com/healthcare/about/customer-support/product-security"
}
],
"sourceIdentifier": "ics-cert@hq.dhs.gov",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-319"
}
],
"source": "ics-cert@hq.dhs.gov",
"type": "Secondary"
},
{
"description": [
{
"lang": "en",
"value": "CWE-319"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
Loading…
Loading…
Drag nodes to arrange them. Double-click a related vulnerability to open it, or a source to visit its link. The Physics button on the left tunes the layout and the simulation; the legend at the bottom left hides or shows nodes by kind and by sighting type.
Experimental. This forecast is provided for visualization only and may change without notice. Do not use it for operational decisions.
Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.
Sightings
| Author | Source | Type | Date | Other |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Vulnerability timeline
Sightings and recorded dates, grouped by day · UTC
Loading timeline…
Loading…
Loading…
The MITRE ATT&CK techniques below are AI-generated suggestions, inferred from the description of the
vulnerability by the CIRCL/vulnerability-attack-technique-classification-roberta-base
model, served locally by ML-Gateway.
They have not been verified by an analyst and are provided for guidance only.
The approach is described in our paper Mapping CVEs to MITRE ATT&CK Techniques: A Curated Gold-Set Classifier and the Limits of LLM-Assisted Label Expansion.
Browse all ATT&CK techniques and the vulnerabilities related to each.
The approach is described in our paper Mapping CVEs to MITRE ATT&CK Techniques: A Curated Gold-Set Classifier and the Limits of LLM-Assisted Label Expansion.
Browse all ATT&CK techniques and the vulnerabilities related to each.
Loading…
Related by attack behaviour
Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.