FKIE_CVE-2012-6437

Vulnerability from fkie_nvd - Published: 2013-01-24 21:55 - Updated: 2026-06-16 23:48
Summary
The device does not properly authenticate users and the potential exists for a remote user to upload a new firmware image to the Ethernet card, whether it is a corrupt or legitimate firmware image. Successful exploitation of this vulnerability could cause loss of availability, integrity, and confidentiality and a disruption in communications with other connected devices. Rockwell Automation EtherNet/IP products; 1756-ENBT, 1756-EWEB, 1768-ENBT, and 1768-EWEB communication modules; CompactLogix L32E and L35E controllers; 1788-ENBT FLEXLogix adapter; 1794-AENTR FLEX I/O EtherNet/IP adapter; ControlLogix 18 and earlier; CompactLogix 18 and earlier; GuardLogix 18 and earlier; SoftLogix 18 and earlier; CompactLogix controllers 19 and earlier; SoftLogix controllers 19 and earlier; ControlLogix controllers 20 and earlier; GuardLogix controllers 20 and earlier; and MicroLogix 1100 and 1400

{
  "affected": [
    {
      "affectedData": [
        {
          "defaultStatus": "unaffected",
          "product": "1756-ENBT, 1756-EWEB, 1768-ENBT, 1768-EWEB communication modules",
          "vendor": "Rockwell Automation",
          "versions": [
            {
              "status": "affected",
              "version": "All"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "CompactLogix L32E and L35E controllers",
          "vendor": "Rockwell Automation",
          "versions": [
            {
              "status": "affected",
              "version": "All"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "1788-ENBT FLEXLogix adapter",
          "vendor": "Rockwell Automation",
          "versions": [
            {
              "status": "affected",
              "version": "All"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "1794-AENTR FLEX I/O EtherNet/IP adapter",
          "vendor": "Rockwell Automation",
          "versions": [
            {
              "status": "affected",
              "version": "All"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "ControlLogix, CompactLogix, GuardLogix, and SoftLogix",
          "vendor": "Rockwell Automation",
          "versions": [
            {
              "lessThanOrEqual": "18",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "CompactLogix and SoftLogix controllers",
          "vendor": "Rockwell Automation",
          "versions": [
            {
              "lessThanOrEqual": "19",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "ControlLogix and GuardLogix controllers",
          "vendor": "Rockwell Automation",
          "versions": [
            {
              "lessThanOrEqual": "20",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MicroLogix",
          "vendor": "Rockwell Automation",
          "versions": [
            {
              "status": "affected",
              "version": "1100"
            },
            {
              "status": "affected",
              "version": "1400"
            }
          ]
        }
      ],
      "source": "ics-cert@hq.dhs.gov"
    }
  ],
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:rockwellautomation:controllogix_controllers:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "37F4D4ED-1915-4155-9F0A-691771AA534B",
              "versionEndIncluding": "20",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:rockwellautomation:guardlogix_controllers:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "A2F8B5EE-C1BA-4CFB-B17F-C59BCDB41503",
              "versionEndIncluding": "20",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:rockwellautomation:micrologix:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "DE554CCC-0A46-43D4-8D7D-44200BB7D314",
              "versionEndIncluding": "1100",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:rockwellautomation:micrologix:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "8D3B4218-4483-4FAE-9915-8937F40AED27",
              "versionEndIncluding": "1400",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:rockwellautomation:softlogix_controllers:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "FE7219A5-4759-4143-B89F-869D49CAAFF7",
              "versionEndIncluding": "19",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:h:rockwellautomation:1756-enbt:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "330E9A05-C869-41B1-BB28-FD2A7C7ED0CE",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:h:rockwellautomation:1756-eweb:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "2AD7D5DB-4A49-421A-8C6C-B9E6DA0A499B",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:h:rockwellautomation:1768-enbt:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "DD44B55C-BDD7-41CC-91A9-F31ED2FC69E2",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:h:rockwellautomation:1768-eweb:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "C91D5245-DED2-469C-A800-62109F8159C9",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:h:rockwellautomation:1794-aentr_flex_i\\/o_ethernet\\/ip_adapter:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "0BD25E6B-6AE1-4B8C-A086-F5E152CAAA60",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:h:rockwellautomation:compactlogix:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "AA199887-E8F7-48EE-B1E0-9EF2E439DACE",
              "versionEndIncluding": "18",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:h:rockwellautomation:compactlogix_controllers:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "A763D845-B091-47A4-8A29-A1CD19C1E4F2",
              "versionEndIncluding": "19",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:h:rockwellautomation:compactlogix_l32e_controller:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "19B8ED27-2512-4A42-973C-99D300963046",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:h:rockwellautomation:compactlogix_l35e_controller:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "7EFC590C-01C1-48D1-A5BE-0F70BE7F36B9",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:h:rockwellautomation:controllogix:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "4FE24B9B-9F7D-4D8F-A674-F04FC9F9F8BC",
              "versionEndIncluding": "18",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:h:rockwellautomation:flexlogix_1788-enbt_adapter:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "887A3369-548C-42B0-82C5-92CB161D3B7A",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:h:rockwellautomation:guardlogix:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "E98626DD-BC79-473E-B25F-92C9BA12F6DD",
              "versionEndIncluding": "18",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:h:rockwellautomation:softlogix:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "D83AF504-2845-4022-BA8E-52F4FB773EA4",
              "versionEndIncluding": "18",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "The device does not properly authenticate users and the potential exists for a remote user to upload a new firmware image to the Ethernet card, whether it is a corrupt or legitimate firmware image. Successful exploitation of this vulnerability could cause loss of availability, integrity, and confidentiality and a disruption in communications with other connected devices.\n\n\n\n\n\nRockwell Automation EtherNet/IP products; 1756-ENBT, 1756-EWEB, 1768-ENBT, and 1768-EWEB communication modules; CompactLogix L32E and L35E controllers; 1788-ENBT FLEXLogix adapter; 1794-AENTR FLEX I/O EtherNet/IP adapter; ControlLogix 18 and earlier; CompactLogix 18 and earlier; GuardLogix 18 and earlier; SoftLogix 18 and earlier; CompactLogix controllers 19 and earlier; SoftLogix controllers 19 and earlier; ControlLogix controllers 20 and earlier; GuardLogix controllers 20 and earlier; and MicroLogix 1100 and 1400"
    },
    {
      "lang": "es",
      "value": "Rockwell Automation EtherNet/IP; productos 1756-ENBT, 1756-EWEB, 1768-ENBT y m\u00f3dulos de comunicaci\u00f3n 1768-EWEB; CompactLogix L32E y L35E, 1788-ENBT adaptador FlexLogix; AENTR 1794-FLEX adaptador I/O EtherNet/IP; ControlLogix v18 y anteriores; CompactLogix 18 y anteriores; GuardLogix 18 y anteriores; SoftLogix v18 y anteriores; controladores CompactLogix v19 y anteriores; controladores SoftLogix v19 y anteriores; controladores ControlLogix v20 y anteriores, los controladores GuardLogix v20 y anteriores, y MicroLogix 1100 y 1400 no realizan correctamente la autenticaci\u00f3n para actualizaciones de firmware Ethernet, lo que permite a atacantes remotos ejecutar c\u00f3digo arbitrario a trav\u00e9s de un troyano que  se hace pasar por una actualizaci\u00f3n."
    }
  ],
  "id": "CVE-2012-6437",
  "lastModified": "2026-06-16T23:48:06.267",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "HIGH",
        "cvssData": {
          "accessComplexity": "LOW",
          "accessVector": "NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "COMPLETE",
          "baseScore": 10.0,
          "confidentialityImpact": "COMPLETE",
          "integrityImpact": "COMPLETE",
          "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
          "version": "2.0"
        },
        "exploitabilityScore": 10.0,
        "impactScore": 10.0,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "ics-cert@hq.dhs.gov",
        "type": "Secondary",
        "userInteractionRequired": false
      },
      {
        "acInsufInfo": false,
        "baseSeverity": "HIGH",
        "cvssData": {
          "accessComplexity": "LOW",
          "accessVector": "NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "COMPLETE",
          "baseScore": 10.0,
          "confidentialityImpact": "COMPLETE",
          "integrityImpact": "COMPLETE",
          "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
          "version": "2.0"
        },
        "exploitabilityScore": 10.0,
        "impactScore": 10.0,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 9.8,
          "baseSeverity": "CRITICAL",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 5.9,
        "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
        "type": "Secondary"
      }
    ],
    "ssvcV203": [
      {
        "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
        "ssvcData": {
          "id": "CVE-2012-6437",
          "options": [
            {
              "exploitation": "none"
            },
            {
              "automatable": "yes"
            },
            {
              "technicalImpact": "total"
            }
          ],
          "role": "CISA Coordinator",
          "timestamp": "2026-06-03T13:39:03.654457Z",
          "version": "2.0.3"
        }
      }
    ]
  },
  "published": "2013-01-24T21:55:01.523",
  "references": [
    {
      "source": "ics-cert@hq.dhs.gov",
      "url": "http://rockwellautomation.custhelp.com/app/answers/detail/a_id/54102"
    },
    {
      "source": "ics-cert@hq.dhs.gov",
      "url": "https://rockwellautomation.custhelp.com/app/answers/detail/a_id/470154"
    },
    {
      "source": "ics-cert@hq.dhs.gov",
      "url": "https://rockwellautomation.custhelp.com/app/answers/detail/aid/470155"
    },
    {
      "source": "ics-cert@hq.dhs.gov",
      "url": "https://rockwellautomation.custhelp.com/app/answers/detail/aid/470156"
    },
    {
      "source": "ics-cert@hq.dhs.gov",
      "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-13-011-03"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "US Government Resource"
      ],
      "url": "http://www.us-cert.gov/control_systems/pdf/ICSA-13-011-03.pdf"
    }
  ],
  "sourceIdentifier": "ics-cert@hq.dhs.gov",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-287"
        }
      ],
      "source": "ics-cert@hq.dhs.gov",
      "type": "Secondary"
    },
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-287"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Secondary"
    }
  ]
}



Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Drag nodes to arrange them. Double-click a related vulnerability to open it, or a source to visit its link. The Physics button on the left tunes the layout and the simulation; the legend at the bottom left hides or shows nodes by kind and by sighting type.

Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.

Sightings

Author Source Type Date Other

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Vulnerability timeline

Sightings and recorded dates, grouped by day · UTC

JSON
How durations are calculated

Following the VTEM framework (Black Hat USA 2015), time to patch starts when the vendor or a coordinator was informed, total time to patch at discovery, and disclosure to patch at public disclosure; vendor response time runs from the report to its acknowledgement. Time to exploit and time unpatched start at the earliest discovery or report, falling back to public disclosure. Unpatched time ends at the first recorded patch, or the calculation time when no patch is recorded. Exploitation to patch shows the interval between those two events; a published proof of concept is a public exploit, not exploitation.

Each result shows its source dates. A negative interval means the end event came first; when date-only inputs leave the order open, the result says so. Date-only inputs are approximate. The earliest evidence wins: KEV report dates and sightings are labelled as such. Records describing another vulnerability are listed but never calculated from, and a PoC alone does not establish exploitation. Missing patch evidence does not prove that no patch exists. Filters below change the event list only.

Events included in the timeline

Loading timeline…


    Loading…

    Loading…

    Loading…

    Related by attack behaviour

    Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.