GCVE Workshop - 22 September 2026 (14:00-18:00), Luxembourg Before The Vulnopticon Conference - Registration

FKIE_CVE-2010-3460

Vulnerability from fkie_nvd - Published: 2010-09-17 20:00 - Updated: 2026-06-16 23:22
Severity
Summary
Directory traversal vulnerability in the HTTP interface in AXIGEN Mail Server 7.4.1 for Windows allows remote attackers to read arbitrary files via a %5C (encoded backslash) in the URL.
Impacted products
Vendor Product Version
gecad axigen_mail_server *
gecad axigen_mail_server -
gecad axigen_mail_server 1.0.1
gecad axigen_mail_server 1.0.2
gecad axigen_mail_server 1.0.5
gecad axigen_mail_server 1.0.6
gecad axigen_mail_server 1.0.7
gecad axigen_mail_server 1.1.0
gecad axigen_mail_server 1.1.0
gecad axigen_mail_server 1.1.1
gecad axigen_mail_server 1.2.0
gecad axigen_mail_server 1.2.0
gecad axigen_mail_server 1.2.3
gecad axigen_mail_server 1.2.4
gecad axigen_mail_server 1.2.5
gecad axigen_mail_server 1.2.5
gecad axigen_mail_server 1.2.6
gecad axigen_mail_server 2.0
gecad axigen_mail_server 2.0.3
gecad axigen_mail_server 2.0.4
gecad axigen_mail_server 2.0.5
gecad axigen_mail_server 3.0
gecad axigen_mail_server 3.0
gecad axigen_mail_server 3.0.1
gecad axigen_mail_server 4.0
gecad axigen_mail_server 4.0
gecad axigen_mail_server 4.0.1
gecad axigen_mail_server 4.0.2
gecad axigen_mail_server 5.0
gecad axigen_mail_server 5.0
gecad axigen_mail_server 5.0.1
gecad axigen_mail_server 5.0.2
gecad axigen_mail_server 5.0.3
gecad axigen_mail_server 6.0.1
gecad axigen_mail_server 6.1
gecad axigen_mail_server 6.1
gecad axigen_mail_server 6.2
gecad axigen_mail_server 6.2.2
gecad axigen_mail_server 7.0
gecad axigen_mail_server 7.0
gecad axigen_mail_server 7.1
gecad axigen_mail_server 7.1.1
gecad axigen_mail_server 7.1.2
gecad axigen_mail_server 7.1.3
gecad axigen_mail_server 7.1.4
gecad axigen_mail_server 7.2
gecad axigen_mail_server 7.2
gecad axigen_mail_server 7.2.1
gecad axigen_mail_server 7.3
gecad axigen_mail_server 7.3
gecad axigen_mail_server 7.3.1
gecad axigen_mail_server 7.3.2
gecad axigen_mail_server 7.3.3
gecad axigen_mail_server 7.4
gecad axigen_mail_server 7.4
microsoft windows *

{
  "affected": [
    {
      "affectedData": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "source": "cve@mitre.org"
    }
  ],
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:gecad:axigen_mail_server:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "6FC4AA81-6053-44C4-9129-17BC364767BD",
              "versionEndIncluding": "7.4.1",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:gecad:axigen_mail_server:-:beta3:*:*:*:*:*:*",
              "matchCriteriaId": "9C8AA4B4-B9B4-46E8-B3B6-4616DDCABB8F",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:gecad:axigen_mail_server:1.0.1:*:*:*:*:*:*:*",
              "matchCriteriaId": "E62797EB-6B31-42C8-8070-A126B7824358",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:gecad:axigen_mail_server:1.0.2:*:*:*:*:*:*:*",
              "matchCriteriaId": "39DE274D-CFC3-4A07-BA41-E761C7B2492E",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:gecad:axigen_mail_server:1.0.5:*:*:*:*:*:*:*",
              "matchCriteriaId": "2B44215D-3BC3-4F69-BA25-BB245D8334E2",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:gecad:axigen_mail_server:1.0.6:*:*:*:*:*:*:*",
              "matchCriteriaId": "153FE68B-BF39-4A48-8661-133441E6A9FA",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:gecad:axigen_mail_server:1.0.7:*:*:*:*:*:*:*",
              "matchCriteriaId": "4E4FB74E-F428-4D8B-8348-0BDD4640071E",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:gecad:axigen_mail_server:1.1.0:*:*:*:*:*:*:*",
              "matchCriteriaId": "E7123D3C-EBCA-4EAE-BDB9-1BDD0DEA5AF5",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:gecad:axigen_mail_server:1.1.0:beta1:*:*:*:*:*:*",
              "matchCriteriaId": "478F93E7-0C69-4F5E-8B2B-2E594D418131",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:gecad:axigen_mail_server:1.1.1:*:*:*:*:*:*:*",
              "matchCriteriaId": "1D44F284-E5F9-49AE-81FB-FE3C8D046D59",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:gecad:axigen_mail_server:1.2.0:*:*:*:*:*:*:*",
              "matchCriteriaId": "A72E9D23-3A65-4BE3-8867-5F96865389C9",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:gecad:axigen_mail_server:1.2.0:beta:*:*:*:*:*:*",
              "matchCriteriaId": "0F6D81E6-B50A-4355-A3E1-8041B7328DC5",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:gecad:axigen_mail_server:1.2.3:*:*:*:*:*:*:*",
              "matchCriteriaId": "FB64A58D-FD23-44A2-9F79-5E856FDB38C6",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:gecad:axigen_mail_server:1.2.4:*:*:*:*:*:*:*",
              "matchCriteriaId": "69532EAC-4A32-44C8-A51B-3E39A7106F09",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:gecad:axigen_mail_server:1.2.5:*:*:*:*:*:*:*",
              "matchCriteriaId": "AEECFFB8-4792-42B4-BD3C-3016BE4330F0",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:gecad:axigen_mail_server:1.2.5:b:*:*:*:*:*:*",
              "matchCriteriaId": "A22932ED-5F58-4DDD-88C6-95548E1A1AFA",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:gecad:axigen_mail_server:1.2.6:*:*:*:*:*:*:*",
              "matchCriteriaId": "3444AE24-8B86-459C-98C9-6820FEC95D5F",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:gecad:axigen_mail_server:2.0:*:*:*:*:*:*:*",
              "matchCriteriaId": "65C30393-380E-4728-99AB-8B2C7B81B6A7",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:gecad:axigen_mail_server:2.0.3:*:*:*:*:*:*:*",
              "matchCriteriaId": "D919CD37-E987-4391-9602-C8C221A29919",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:gecad:axigen_mail_server:2.0.4:*:*:*:*:*:*:*",
              "matchCriteriaId": "3407900D-7B76-4D8A-8F10-BFF3B497CD1C",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:gecad:axigen_mail_server:2.0.5:*:*:*:*:*:*:*",
              "matchCriteriaId": "26FFAAD5-FCF2-420B-9B91-9EAFCAB59A63",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:gecad:axigen_mail_server:3.0:*:*:*:*:*:*:*",
              "matchCriteriaId": "368A9606-ED73-48BF-B923-E51C9018F042",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:gecad:axigen_mail_server:3.0:beta:*:*:*:*:*:*",
              "matchCriteriaId": "001C19A6-1D99-476D-B9DB-6D9E3E5D1E8E",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:gecad:axigen_mail_server:3.0.1:*:*:*:*:*:*:*",
              "matchCriteriaId": "98F794BC-242C-4B7C-83FB-607EED78FD3E",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:gecad:axigen_mail_server:4.0:*:*:*:*:*:*:*",
              "matchCriteriaId": "44FB322C-AD7E-4481-95D2-CE1CAC3F5B53",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:gecad:axigen_mail_server:4.0:beta:*:*:*:*:*:*",
              "matchCriteriaId": "98D94943-C343-4AF4-844B-6886B4F24421",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:gecad:axigen_mail_server:4.0.1:*:*:*:*:*:*:*",
              "matchCriteriaId": "FA886A97-82AA-4488-8A7E-5EE5A292E38F",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:gecad:axigen_mail_server:4.0.2:*:*:*:*:*:*:*",
              "matchCriteriaId": "FF07D225-6227-4266-9207-5CCFCCD3371C",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:gecad:axigen_mail_server:5.0:*:*:*:*:*:*:*",
              "matchCriteriaId": "6BEDE33D-25F3-44E6-87EC-0D16096DFF03",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:gecad:axigen_mail_server:5.0:beta:*:*:*:*:*:*",
              "matchCriteriaId": "EF1B1841-99C6-45D0-97CE-EF7A2F0CF7FD",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:gecad:axigen_mail_server:5.0.1:*:*:*:*:*:*:*",
              "matchCriteriaId": "4DF74869-E66A-4E43-9286-6F30AAA8CEFE",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:gecad:axigen_mail_server:5.0.2:*:*:*:*:*:*:*",
              "matchCriteriaId": "BDC45FBA-D58C-4775-9225-D4E0F7117510",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:gecad:axigen_mail_server:5.0.3:*:*:*:*:*:*:*",
              "matchCriteriaId": "9392DE24-CF35-4805-911C-B7EBF5C16392",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:gecad:axigen_mail_server:6.0.1:*:*:*:*:*:*:*",
              "matchCriteriaId": "E52309DC-D0C4-4C5A-9BA6-900361466BCB",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:gecad:axigen_mail_server:6.1:*:*:*:*:*:*:*",
              "matchCriteriaId": "0C89FD65-166B-40A8-921D-53A28D422219",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:gecad:axigen_mail_server:6.1:beta:*:*:*:*:*:*",
              "matchCriteriaId": "B58CFD7F-985B-40BE-A783-3F63A3F3762A",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:gecad:axigen_mail_server:6.2:*:*:*:*:*:*:*",
              "matchCriteriaId": "D92B63E6-71FD-43AE-BF9C-1E498B0BF6E8",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:gecad:axigen_mail_server:6.2.2:*:*:*:*:*:*:*",
              "matchCriteriaId": "30879EDE-262D-4CD7-B67C-39ABEB945881",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:gecad:axigen_mail_server:7.0:*:*:*:*:*:*:*",
              "matchCriteriaId": "A87B2A89-293B-4AF9-9F3A-B0C1EB401087",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:gecad:axigen_mail_server:7.0:beta:*:*:*:*:*:*",
              "matchCriteriaId": "C09BD3CB-603A-41E8-97A4-EE79ED417D4F",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:gecad:axigen_mail_server:7.1:*:*:*:*:*:*:*",
              "matchCriteriaId": "EE805B25-80EF-4F7D-9C0F-ACE13DBC0BB2",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:gecad:axigen_mail_server:7.1.1:*:*:*:*:*:*:*",
              "matchCriteriaId": "07478BE4-1082-4F17-AC7C-3664E94126B3",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:gecad:axigen_mail_server:7.1.2:*:*:*:*:*:*:*",
              "matchCriteriaId": "42C9F3E3-1027-49CD-9A58-D8AC48F53020",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:gecad:axigen_mail_server:7.1.3:*:*:*:*:*:*:*",
              "matchCriteriaId": "B0E3AC95-B859-49DB-8AC2-3DA59862132B",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:gecad:axigen_mail_server:7.1.4:*:*:*:*:*:*:*",
              "matchCriteriaId": "825E857B-0335-40E4-83C8-35BE6DE46E7A",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:gecad:axigen_mail_server:7.2:*:*:*:*:*:*:*",
              "matchCriteriaId": "041F7DB5-3B50-42EC-8F82-59692E7695B9",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:gecad:axigen_mail_server:7.2:beta:*:*:*:*:*:*",
              "matchCriteriaId": "7077934E-3E6A-46B1-82EA-1C255B91B5E8",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:gecad:axigen_mail_server:7.2.1:*:*:*:*:*:*:*",
              "matchCriteriaId": "4452E962-2D15-440A-B202-64E4D108DC36",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:gecad:axigen_mail_server:7.3:*:*:*:*:*:*:*",
              "matchCriteriaId": "60997606-A019-4EEA-9448-34FE0AF53C4A",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:gecad:axigen_mail_server:7.3:beta:*:*:*:*:*:*",
              "matchCriteriaId": "9CEC4BBF-D686-4F1D-9A67-9265899406CD",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:gecad:axigen_mail_server:7.3.1:*:*:*:*:*:*:*",
              "matchCriteriaId": "B478AA48-E200-41DF-AF5C-165F9EAC6A28",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:gecad:axigen_mail_server:7.3.2:*:*:*:*:*:*:*",
              "matchCriteriaId": "94467CF0-FA6B-43EA-9734-723DF21E0236",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:gecad:axigen_mail_server:7.3.3:*:*:*:*:*:*:*",
              "matchCriteriaId": "9F0AFE6B-3CE6-4F7A-B0C7-79608FEF7F05",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:gecad:axigen_mail_server:7.4:*:*:*:*:*:*:*",
              "matchCriteriaId": "A71769EC-A983-42B1-96AB-FD145CA23BAD",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:gecad:axigen_mail_server:7.4:beta:*:*:*:*:*:*",
              "matchCriteriaId": "1A568477-89D4-4DCF-802B-52388BC9DA33",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:microsoft:windows:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "2CF61F35-5905-4BA9-AD7E-7DB261D2F256",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "Directory traversal vulnerability in the HTTP interface in AXIGEN Mail Server 7.4.1 for Windows allows remote attackers to read arbitrary files via a %5C (encoded backslash) in the URL."
    },
    {
      "lang": "es",
      "value": "Vulnerabilidad de salto de directorio en la interfaz HTTP en AXIGEN Mail Server v7.4.1 para Windows permite a atacantes remotos leer archivos a su elecci\u00f3n a trav\u00e9s de un %5C (barra invertida codificada) en la URL."
    }
  ],
  "id": "CVE-2010-3460",
  "lastModified": "2026-06-16T23:22:49.233",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "MEDIUM",
        "cvssData": {
          "accessComplexity": "LOW",
          "accessVector": "NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "NONE",
          "baseScore": 5.0,
          "confidentialityImpact": "PARTIAL",
          "integrityImpact": "NONE",
          "vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N",
          "version": "2.0"
        },
        "exploitabilityScore": 10.0,
        "impactScore": 2.9,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": false
      }
    ]
  },
  "published": "2010-09-17T20:00:02.820",
  "references": [
    {
      "source": "cve@mitre.org",
      "tags": [
        "Exploit"
      ],
      "url": "http://packetstormsecurity.org/1009-exploits/axigen741-traversal.txt"
    },
    {
      "source": "cve@mitre.org",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "http://secunia.com/advisories/41430"
    },
    {
      "source": "cve@mitre.org",
      "url": "http://www.acunetix.com/blog/news/directory-traversal-axigen/"
    },
    {
      "source": "cve@mitre.org",
      "tags": [
        "Patch",
        "Vendor Advisory"
      ],
      "url": "http://www.axigen.com/press/product-releases/axigen-releases-version-742_74.html"
    },
    {
      "source": "cve@mitre.org",
      "url": "http://www.osvdb.org/68027"
    },
    {
      "source": "cve@mitre.org",
      "tags": [
        "Exploit"
      ],
      "url": "http://www.securityfocus.com/bid/43230"
    },
    {
      "source": "cve@mitre.org",
      "tags": [
        "Patch",
        "Vendor Advisory"
      ],
      "url": "http://www.vupen.com/english/advisories/2010/2415"
    },
    {
      "source": "cve@mitre.org",
      "url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/61826"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Exploit"
      ],
      "url": "http://packetstormsecurity.org/1009-exploits/axigen741-traversal.txt"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "http://secunia.com/advisories/41430"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "url": "http://www.acunetix.com/blog/news/directory-traversal-axigen/"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Patch",
        "Vendor Advisory"
      ],
      "url": "http://www.axigen.com/press/product-releases/axigen-releases-version-742_74.html"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "url": "http://www.osvdb.org/68027"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Exploit"
      ],
      "url": "http://www.securityfocus.com/bid/43230"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Patch",
        "Vendor Advisory"
      ],
      "url": "http://www.vupen.com/english/advisories/2010/2415"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/61826"
    }
  ],
  "sourceIdentifier": "cve@mitre.org",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-22"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}



Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.

Sightings

Author Source Type Date Other

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.

Loading…

Detection rules are retrieved from Rulezet.

Loading…

Loading…

Related by attack behaviour

Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.


Loading…